STATIKO

Statiko user guide

Structural beam analysis and design to the Eurocodes

App version
0.9.5
Guide date
23 November 2026

Struktura Software

Part I

Getting started

Chapter 1

Installing and signing in

This chapter covers installing Statiko on Windows and getting past the sign-in screen to your projects. Statiko works offline with local project files: your projects and calculations never depend on an online service. In this version, development builds open with Skip sign-in, which needs no account and no internet connection.

Installing on Windows

Statiko for Windows comes as an MSI installer. Installers are published as releases of the public statiko-releases repository, and the download page on the website links there. Each release includes a SHA256SUMS.txt file, so you can check that the download is complete and unchanged.

  1. Download the installer from the Statiko website.
  2. Run it. The installer lets you choose the installation folder. Statiko is installed for every user of the computer.
  3. When setup finishes, start Statiko from the Statiko group in the Start menu or from the desktop shortcut.

The installer also registers project files. Files ending in .statiko appear in Explorer as Statiko project with their own icon, and double-clicking one starts Statiko and opens that project.

Builds outside Production show their environment in the window title, for example Statiko (Staging). A Production build shows just Statiko.

Source: spec/beam/workspace-shell.md rules 29 and 40.

Starting Statiko

On Windows, a small dark window with the Statiko mark, its name and version shows the moment you start it and closes when the first Statiko window opens. Then Statiko shows Opening workspace… while it prepares its workspace folder on your computer. If the folder cannot be created or read, Statiko shows Statiko could not start with one of these reasons:

Fix the folder permissions, then choose Try again.

Next, Statiko decides where to go. If a saved session can be restored, it opens your projects straight away. If it cannot restore one, it shows the sign-in screen. Without a saved session, it opens your projects when this build already lets you create them, and shows the sign-in screen otherwise.

Only one Statiko runs per environment. If you open a project file while Statiko is already running, the file is handed to the running window, which comes to the front and opens it. A project file opened before you have signed in waits and opens once you reach your projects.

Source: spec/beam/workspace-shell.md rules 41 and 42.

The sign-in screen

In a wide window, the sign-in screen has a brand panel on the left with what Statiko does: analysis and Eurocode design of beams and columns, steel, timber and concrete members, Eurocode checks with National Annex values, and offline work with local project files. The sign-in form is on the right. Narrower windows show the form alone. The form scrolls, and it moves up when the on-screen keyboard opens.

The Statiko sign-in screen
Figure 1.1 · The sign-in screen of a development build, showing the Sign-in is unavailable notice, the account options and Skip sign-in

From top to bottom, the form holds:

The footer has the Terms of use and Privacy links, the company name and the version, for example Struktura Software · Version 0.9.5 (debug). Debug builds add (debug) to the version.

Continue with Apple is not available in this version. The button is always disabled and says Coming soon.

Skip sign-in: working offline

Skip sign-in is how you open Statiko in this version. It takes you straight to your projects in development access, with no account and no internet connection.

  1. On the sign-in screen, choose Skip sign-in.
  2. The hub opens on Projects. The navigation shows Development access where your account would be.

Development access grants no account and no paid licence. In the hub it reads Not signed in. Development access grants no account or paid licence., and nothing is saved to an account. Your project files are ordinary files on your computer, so they are not affected.

Skip sign-in stays available when you are offline.

Signing in with an account

Sign-in always finishes in your web browser, never inside Statiko. Type your email, or leave it empty, and choose Continue or Continue with Google. Pressing Enter in the email field does the same as Continue. Statiko opens your browser and shows Continue in your browser with a Cancel button, and the rest of the form is disabled until you finish or cancel. When the browser hands back, the button reads Signing in… until you are in.

These notices can appear above the form:

NoticeWhat it meansWhat you can do
Sign-in was cancelledYou chose Cancel or closed the browser page before finishing.Try again when you are ready.
Verify your emailYour account email is not verified yet.Open the link in the email, or choose Resend email.
You are offlineSigning in needs an internet connection. Google, Continue and Create account are disabled; Forgot password? does nothing while you are offline.Connect and try again, or use Skip sign-in.
Sign-in is unavailableStatiko could not reach the sign-in service, or this build has none.Choose Try again.
Legal documentation is not available yet.The Terms of use or Privacy page has no address in this build.None.

Create account and Forgot password? open the matching pages in your browser. Terms of use and Privacy open the licence and privacy pages on the website.

Licences in this version

Statiko never needs a service to open, calculate or save local projects. Builds without the development entry offer Open existing projects. It opens the hub for reading, where a notice explains: A verified licence is required to create or edit projects. Existing files remain available for reading and recovery.

The beta licence by invitation, the free trial, activated devices with their limits, offline licence periods and Check licence again are not available in this version.

Chapter 2

The hub

The hub is the first place you reach after signing in or choosing Skip sign-in. From here you start and open projects, set the language, theme and engineering units, read the legal documents and the About box, and check your account. It has four sections: Projects, Settings & Units, Documentation & Legal and Profile.

Moving around the hub

The navigation adapts to the size of the window. A wide window has a sidebar on the left. A medium-width window, or a window that is not very tall, has a narrow rail. A phone-width window has a bottom bar with short labels: Projects, Settings and Legal.

The navigation also shows who you are. In development access it reads Development access with Not signed in below it.

Projects

The Projects page is where your work starts. The Open project… button at the top right opens a .statiko file from your computer.

The hub's Projects page with three recent projects
Figure 2.1 · The Projects page: the sidebar with its account block at the bottom, the three Quick start cards and the Recent projects table

Quick start

Three cards start a new project:

CardWhat it does
Quick beam analysisContinuous beam template for quick member analysis.
Quick column analysisColumn stability and buckling template.
Create empty project“Start a blank project and add beams and columns later.” You add them from the workspace (Chapter 3).

The cards are enabled only when this build lets you create projects. When it does not, a notice above them gives the reason, for example No verified licence is available., followed by A verified licence is required to create or edit projects. Existing files remain available for reading and recovery. If column editing is not part of this build, choosing the column card shows Column editing belongs to the next workspace milestone.

Recent projects

Under Recent projects you find the last ten projects you saved or opened. A wide window shows them as a table with the columns Project name, Contents (for example "2 beams, 1 column"), File path, Last modified (for example "Just now", "3 hours ago" or "Yesterday") and Actions.

With no recent projects, the card reads No recent projects, Projects you save or open appear here. with an Open project… button. If the history itself cannot be read or saved, a notice says so, and your project files are not affected.

If a project cannot be opened, the page tells you why:

Settings & Units

Settings take effect as soon as you change them. There is no Save button. After each change a short confirmation appears, such as "Theme changed." or "Metric (SI) preset applied." If a change cannot be stored on this device, the field shows This change could not be stored on this device. Your previous settings are preserved. Reset to defaults at the top restores the system theme, English and the recommended metric units.

General

Units

The Engineering units and precision card sets, for each quantity, the Input unit you type in, the Screen display unit and the PDF report unit, with Decimals from 0 to 8 for display and report. It covers 17 quantities, from Length and Force to Warping constant and Bending stiffness. Unit preset applies Metric (SI) or Imperial (US) in one step.

Units settings with preset buttons and the unit table
Figure 2.2 · Settings & Units, Units tab: the Metric (SI) and Imperial (US) presets above the table of input, screen and report units

The Defaults tab applies everywhere. The Advanced tab overrides units for one app area: Cross-section / detailing, Supports, Loads or Results. A field without an override shows Global (…), and Use global clears the overrides of an area.

The introductory tour

At the first start the hub shows Welcome to Statiko over the Projects page. Choose a tour, Steel, Timber, Glulam or Concrete, and select Take the tour. Not now closes the dialog, and it does not show by itself again.

The tour opens its sample as a new project, so it needs a licence that can create projects. Without one, the dialog does not show by itself; opened from Help or Settings, it keeps Take the tour unavailable and says that the sample needs a verified licence.

Each tour opens its sample beam as a new, unsaved project called Statiko tour · followed by the material. Your own files are not touched; if a project is open, the hub asks you to close it first, as Open project… does. The tour then walks through eight steps: design code, member, supports, loads, structural system, result graphs, checks and report. Each step lights up its part of the window, explains it in a sentence or two and links to the chapter of this guide that covers it. The results shown are Statiko's own calculation of the sample beam. While the tour runs, the beam cannot be edited.

Skip tour, the close button, Esc, Android Back and Finish on the last step end the tour and turn off Show the tour at start. The sample beam stays open for you to try; closing it after a change asks whether to save it, as with any new project. On a phone the tour's card is a sheet at the bottom of the screen, and the tour switches to the tab that holds each step and scrolls its part into view; for Report, at the foot of the checks, the sheet moves to the top of the screen.

To take the tour again, choose Help › Introductory tour… in a project (on a tablet it is in the ☰ menu's Help section), or Start the tour now in Settings & Units › General, which is the way on a phone.

While Show the tour at start is ticked, two hints appear once in a beam project: Add your loads here beside the Loads card while the beam has no load, and Your PDF report beside Report once a report can be made. Got it hides a hint for good; ticking the box again brings back any hint you have not dismissed. Hints do not show during the tour.

Documentation & Legal

This page opens with a reminder headed Engineering responsibility: results, diagrams and reports are engineering aids, and a qualified engineer must review and approve every design before construction or fabrication.

Documentation and Legal page on the licence agreement tab
Figure 2.3 · Documentation & Legal: the engineering responsibility notice, the four tiles and the document tabs

Below it are four tiles. About Statiko shows the version and the company. User guide opens this guide. What's new and Eurocode references are tagged Coming soon and are not available in this version.

The tabs Licence agreement, Privacy and Third-party licences show the documents. The licence agreement and the privacy policy are still being prepared, and the page says that their final text will appear before release. Third-party licences lists the software bundled with Statiko; choose View full third-party notices to read all of it. When a document is also on the website, Open on website opens it in your browser.

About Statiko

The About box shows the version, the company (Struktura Software, strukturasoftware.com) and the licence (Proprietary, all rights reserved). Development builds also show the environment. On Windows, About and the third-party notices open in their own windows, which you can move. Esc or Close closes them. On phones and tablets they open as dialogs.

Profile

Profile shows your account, licence and activated devices. In development access it shows Development access, with the explanation that you are not signed in, that licensing is not checked in development builds and that nothing is saved to an account. Sign in returns you to the sign-in screen and ends development access.

When you are neither signed in nor in development access, the page shows Not signed in with Sign in and Open projects, and an Account card whose email, sign-in method, licence and offline-use rows are empty or Unverified.

Signed-in account management (managing your account, checking the licence again, activated devices and signing out) belongs to the beta licence, which is not available in this version.

Chapter 3

The beam workspace

The beam workspace is the window where you build and check a project. Its frame (title bar, menus, ribbon, analysis tabs and status bar) holds every command around the beam model. The regions inside it hold the inputs, the drawing, the result graphs and the checks, which later chapters describe. Statiko calculates by itself after every valid change, so there is no Calculate button: you edit, and the status bar tells you where the result stands.

Beam workspace with a calculated steel beam
Figure 3.1 · The beam workspace: menus, ribbon, analysis tabs, inspector, canvas with the structural system and graphs, checks column and status bar

Title bar and analysis tabs

The title bar runs across the top of the window. On the left are the logo and the menus. In the centre is the project title, with a marker when there are unsaved changes. On the right are the Windows window controls. Drag the title to move the window, and double-click it to maximise or restore. The title is plain text; to rename the project, use Project properties… (see Project properties).

Below the ribbon is the strip of analysis tabs. Each tab shows a beam or column icon, the analysis name (new beams are named "Beam B1", "Beam B2" and so on) and the unsaved marker. Click a tab to switch analysis; switching alone does not make the project unsaved. With many tabs, scroll the strip sideways with the mouse wheel, and the selected tab moves to the centre. Tabs have no close button, and every analysis always keeps its tab.

The + at the end of the strip adds an analysis. Beam analysis… opens the dialog for a new beam, where Create opens the new beam and Cancel takes you back. Column analysis… belongs to columns, which this guide does not cover yet.

Source: spec/beam/workspace-shell.md rules 1 to 4, 35 and 45.

Menus and shortcuts

The menu bar holds File, Edit, View, Model and Help. Each menu shows its shortcuts at the right.

MenuCommandShortcut
FileNew project…Ctrl+N
New analysis…Ctrl+Shift+N
Open project…Ctrl+O
Recover previous version
Save projectCtrl+S
Save as…Ctrl+Shift+S
Project properties…
Export PDF report…Ctrl+P
Close to launcherCtrl+W
EditUndoCtrl+Z
RedoCtrl+Y or Ctrl+Shift+Z
Settings & Units…Ctrl+,
ModelSection catalogue…
Design code…
Load combinations…
HelpUser guide…
About Statiko

New analysis… opens the same choice as the + on the tab strip. Undo and Redo are disabled when there is nothing to undo or redo. The View menu holds the graph choices Graph list or Dual-axis graph, and Stacked or Tabs. When a choice cannot be used, its tooltip says why. Chapter 11 describes the result graphs. In the Help menu, User guide… opens this guide; Calculation methods… is not available in this version.

A disabled command tells you why in a tooltip when you point at it or move to it with the keyboard. A command that is not built yet says Not available yet.

Using the menus from the keyboard

Source: spec/beam/workspace-shell.md rules 5 to 13.

The ribbon

The ribbon under the title bar holds five icon buttons for the commands you use most:

CommandOpens
Design codeThe design code window (Chapter 5).
Cross-sectionThe profile catalogue, the same as Model › Section catalogue… (Chapter 6).
Load combinationsThe load combinations window (Chapter 15).
ReportThe PDF report export (Chapter 14).
UnitsThe settings window on its Units tab.

Report, File › Export PDF report… and Ctrl+P follow one rule. They work when there is a current result, an outdated result, or a previous result while a new calculation runs. Otherwise they are disabled with No current result is available for a report. Calculate first.

The carbon chip

After the ribbon buttons a chip shows the selected beam's product stage carbon (A1-A3) in kg CO₂e, the same total the report prints. Click it to open the split per material: one row per material with its quantity, factor, kg CO₂e and share, then each factor's source. A material without a saved factor uses the generic conservative value of Boverkets klimatdatabas 02.07.000, named with its resource id. Timber and glulam add the line Biogenic carbon stored (not included), which the total leaves out. While a material has no named factor the chip reads No total and the row No factor; while the result calculates it reads Calculating, and without a mass, a length or a concrete section with detailing it reads Unavailable. With no single beam selected there is no chip. You replace a factor in the cross-section window's Carbon tab (Chapter 6, Chapter 7).

Source: spec/beam/carbon.md rules 1 to 8.

Settings over the project

Units opens the settings window on Units, and Edit › Settings & Units… opens it on General. It holds the same settings as the hub (Settings & Units): interface language, theme, AI agents on Windows, and the engineering units with their Defaults and Advanced tabs. On Windows it is a separate window you can move. Esc or Close returns you to the project.

Source: spec/beam/workspace-shell.md rules 16 to 19.

The status bar

The status bar along the bottom always tells you the state of the result and, when results are current, which combination is shown. Read it after every change.

StatusMeaningReport
Empty projectThe project has no analysis yet.Disabled
Not calculatedNothing to calculate yet, for example a beam with no loads and self-weight off.Disabled
Calculating…A calculation is running (with a turning indicator).Enabled only if a previous result exists
Results current · combinationResults match your inputs. Without a combination selected it reads Results current.Enabled
Results outdatedThe results shown no longer match the inputs.Enabled
Invalid inputAn input is not valid, so nothing can be calculated.Disabled
The beam is not stable with these supports and cannot be calculated.The supports leave the beam free to move.Disabled
Calculation failed, Calculation unsupported, Calculation unavailableNo result could be produced.Disabled

For the last two rows the drawing area also shows an error notice with the reason. The notices have no button: your next change starts a new calculation. The status bar grows to show the full sentence and never cuts it off. Builds outside Production end the status bar with the environment name, for example Staging.

Workspace showing the unstable-beam notice
Figure 3.2 · A beam that is not stable with its supports: the notice on the canvas and in the status bar, every check Unavailable and Report disabled

Source: spec/beam/workspace-shell.md rules 20 to 25 and 36.

Project properties

File › Project properties… is where you rename the project and its analyses and delete analyses.

  1. Open Project properties…. The Project name field is selected, ready for typing.
  2. Edit the project name and the analysis names (Analysis 1, Analysis 2 and so on).
  3. To delete an analysis, choose its red bin button, Delete analysis. The row disappears at once, with no confirmation.
  4. Choose OK to apply everything, or Cancel or Esc to leave without changes.
Project properties with a duplicate analysis name
Figure 3.3 · Project properties with two analyses of the same name: the error under each field and OK disabled

OK applies all renames and deletions together as one undo step, so Ctrl+Z brings a deleted analysis back. Leading and trailing spaces are removed. OK stays disabled while a field shows Enter a project name., Enter an analysis name. or Another analysis already has this name.

Source: spec/beam/workspace-shell.md rules 14 and 15.

Saving, opening and closing

The project file dialog shows only Project file (*.statiko). When you save, Statiko adds .statiko if the name lacks it. The first save of a new project suggests the project name as the file name, and Save as… proposes the current file. A project that is still named Untitled, or has no name, takes the name of the file you save it to, so the title bar, the recent list and the report show the same name; a project you have named keeps its name whatever the file is called. Both dialogs start in the folder of the last project you opened, which Statiko remembers between sessions.

A project remembers the analysis that was selected when you saved it and opens on that analysis. If the file has no valid saved analysis, it opens with nothing selected, and the workspace offers to open or create one.

If you close to the launcher, close the window, or start or open another project while there are unsaved changes, Unsaved changes asks what to do: Save, Discard and close or Cancel.

If saving fails, the notice Save failed / The file could not be saved. offers Try again and Save as. Your work and its results stay as they were, and the unsaved markers remain until a save succeeds.

Source: spec/beam/workspace-shell.md rules 31, 32, 37 to 44.

Window sizes

From 840 to 1199 dp wide, the inputs panel (the inspector) sits on the left beside one scrolling column with the drawing, graphs and checks. From 1200 dp, the checks get their own column on the right. The smallest desktop window is 840 × 600 dp. Tab moves through the title bar, the ribbon, the inspector, the drawing, the checks and the status bar, in that order. Smaller windows, phones and tablets are covered in Chapter 4.

Source: spec/beam/workspace-shell.md rules 26 to 28.

Chapter 4

Phones and tablets

On Android phones, tablets and foldables, Statiko gives you the same beam workspace as on the desktop, arranged for small screens and touch. The features, inputs and numbers are the same: every result comes from the same calculation as on the desktop. This chapter shows where things move on a phone, how a touch tablet differs from the desktop, and how Back, the keyboard and rotation behave.

Which layout you get

Statiko picks the layout from the size of the window, not from the kind of device:

WindowLayout
Narrower than 600 dp (phones)The phone layout: one column with Model, Results and Checks tabs.
600 to 839 dp (small tablets, open foldables)The same phone layout, with a wider drawing.
Less than 480 dp tallThe phone layout at any width. Panes scroll, and sheets take at most 85 % of the height.
Touch tablets 840 dp and widerThe desktop regions of Chapter 3 with a touch menu.

On a foldable in book or tabletop posture, the whole workspace sits on one side of the fold, sized to that side. The other side shows Not available yet.

Source: spec/beam/phone-and-tablet.md rules 1 to 4.

The phone workspace

At the top of the phone workspace is the app bar. It holds:

Below the title, a subtitle shows the calculation state, such as Calculating… or Results outdated, in full. Under the app bar are three tabs:

While a calculation runs, the Results and Checks tabs show a small turning indicator, so you can see when they are being refreshed.

Switching analysis

Tap the analysis title to open the analysis switcher, a sheet that slides up from the bottom and lists the analyses in the project. Pick one, or close the sheet with Done.

Source: spec/beam/phone-and-tablet.md rules 6 to 10.

Editing on a phone

When you tap an input on the Model tab, its editor opens as a sheet from the bottom, with a handle, a dimmed background and Done. Done stays above the on-screen keyboard, so you can always close the editor.

Unfinished entries such as - or 1, stay as you typed them and are not treated as a value until they are valid, so you can finish typing. With a hardware keyboard, Tab follows the order on screen, including the unit buttons.

The structural system keeps its full symbol sizes on the phone, in a drawing 247 dp tall. On the Results tab, each graph is 280 dp high. Graph list with tabs is the default, and the toolbar above the graphs keeps the viewing and layout choices, including the dual-axis graph (Chapter 11).

On the Checks tab you see either the list of checks or one opened check, never both. Tap a check card to open it, and use Back to return to the list (Chapter 12).

Source: spec/beam/phone-and-tablet.md rules 11 to 15.

Touch tablets

A touch tablet 840 dp or wider shows the same regions as the desktop: the inspector, the drawing and graphs and, from 1200 dp, the checks column. There are no window controls. The desktop menu bar is replaced by a ☰ button, Main menu, which holds the same five sections: File, Edit, View, Model and Help. At the right are the Settings cog, Undo and Redo.

Every touch target is at least 48 dp. On a tablet, editors open inline under their card instead of as sheets.

Source: spec/beam/phone-and-tablet.md rules 16 and 17.

Android Back, rotation and text size

Back closes the innermost thing first. Each press closes, in this order:

  1. the settings;
  2. the report's Custom page;
  3. the report export view, like Cancel, keeping what you chose;
  4. an opened check;
  5. an open editor sheet;
  6. the analysis switcher;
  7. the workspace itself, back to the launcher. If the project has unsaved changes, Unsaved changes asks first whether to save.

Phones stay in portrait. Tablets and foldables rotate, and when you rotate or fold the device, Statiko keeps the project, the analysis, the selected tab, an open editor with what you are typing, and the selected combination.

With large text (up to 200 %), input values move under their labels, a region may switch to the next smaller layout, and titles wrap rather than being cut off. Units and the status text are never truncated.

Source: spec/beam/phone-and-tablet.md rules 5, 18 and 19.

Reports on phones and tablets

Report on the phone Checks tab, and Export PDF report… in the tablet menu, open the report export view. Below 840 dp it fills the screen, with a Back button, the detail choice, the form sections and the footer. At 840 dp and wider it opens as a centred dialog. As on the desktop, both are disabled with No current result is available for a report. Calculate first. when there is no result to report. Back and Cancel return to the beam and keep your choices.

Below 600 dp, Custom opens as its own page with Back to export options. From 600 to 839 dp it opens in place. On a foldable the export view stays on one side of the fold.

Source: spec/beam/phone-and-tablet.md rules 20 to 22.

Part II

Modelling a beam

Chapter 5

Design code, member and load combinations

The three cards at the top of the beam inspector tell you what Statiko calculates with: the standard and National Annex of the project, the member you are checking, and the load combination that the drawing, the graphs and the checks currently show. The cards show values and compute nothing. This chapter explains each card, the Design code dialog behind it, and how the deflection limits work.

The inspector sections

The inspector lists its sections in a fixed order: Design Code, Member, Supports, Loads and Load Combinations. Each section has an icon, a title and a divider. Design code, Member and Load combinations use the same icons as their ribbon commands.

Design code, Member and Load combinations are read cards. You change their contents through an Edit or Change section action, which opens the owning dialog, window or catalogue. The only inputs you edit directly on the Member card are the width and height of a rectangular section, the Product standard select of a steel beam and the Top flange laterally restrained checkbox.

Source: spec/beam/design-code-member-combinations.md rules 1–3.

The Design Code card

The card has three rows:

The card has no γM row and no consequence-class row; you find those values in the dialog. The pencil button (Edit) on the card header opens the Design code dialog on its first tab.

Design Code and Member cards for an IPE 220 beam
Figure 5.1 · The Design Code card and the Member card of an IPE 220 S355 beam

Source: spec/beam/design-code-member-combinations.md rules 4–6.

The Design code dialog

Open the dialog with the pencil button on the card, the ribbon command Design code or Model › Design code…. On desktop it opens as its own window with a title bar: you can drag it, the workspace stays drawn behind it, and a click outside does not close it. Cancel, the close control and Esc close it without changes; Apply writes your choices to the project.

Country and code

The select Design standard and National Annex offers five choices: Eurocode recommended values, Denmark (DS EN), Sweden (SS EN), Serbia (SRPS EN) and Custom values. Below it you set:

The left column holds Country & Code and the material factor groups: Steel material factors γM0, γM1, γM2 with the Robustness multiplier; Timber material factors (service class, γM,Solid, γM,Glulam, γ3, ksys); Concrete γC, γS, αcc, αct.

Tabs

TabWhat it shows
Psi factors and actionsThe consequence factor KFI with its source; Action partial factors γQ,1, γQ,i, γG,inf, γG,sup; Ψ0, Ψ1 and Ψ2 per action, grouped under imposed loads, snow loads and wind actions; under the table, the Custom Load with its own γQ, ψ0, ψ1 and ψ2.
Load durationOne choice per action: Permanent, Long-term, Medium-term, Short-term or Instantaneous.
Deflection limitsThe Preset select and the five limit fields described below.
Custom CombinationsThe table of the project's custom combinations, described below.

For a concrete beam the steel and timber factor groups are hidden. For the other materials, the concrete group shows γC, γS, αcc and αct; γC,fi and γS,fi stay hidden.

Custom values

The Custom Load block is editable under every country. Its Values select offers Own values and the live load categories A to H. A category fills the four fields with that category's ψ factors and the γQ,1 of the selected country, and follows the country when you change it. Typing in a field turns the select to Own values and keeps the other three values. γQ must be a number above zero; each ψ must be from 0 to 1, otherwise the field shows Enter a number from 0 to 1. A new project starts at γQ = 1.5 and ψ0 = ψ1 = ψ2 = 1.0. The factors are stored with the project and apply to every Custom load in it (Chapter 15).

With Custom values the factor rows become number fields. A field that is not a finite number above zero shows Enter a finite number greater than zero. Custom adds one timber field, kcr, after γ3. It starts empty. Enter a value above 0 and up to 1, or leave it empty; anything else shows Enter a number greater than zero and at most 1, or leave it empty. Apply stays disabled while a custom factor or limit is invalid. If Apply fails, the dialog shows The selection could not be applied. Try again.

Design Code dialog set to Denmark
Figure 5.2 · The Design Code dialog for Denmark (DS EN): Country & Code and the material factors on the left, the Psi factors and actions tab open on the right, beside the Load duration, Deflection limits and Custom Combinations tabs

Custom combinations

The Custom Combinations tab holds the combinations you define yourself, next to the ones Statiko generates. The Load combinations window has the same tab (below); both edit the one list of the project. The table has one row per combination and one column per load case of the project: the permanent load, every load case a load of any beam or column has, and every load case a combination already holds a factor for, in the order dead, live A to H, snow, wind and Custom load. A row holds the Name, the Limit state (ULS, SLS · Characteristic, SLS · Frequent, SLS · Quasi-permanent or Fire), one factor field per load case and a delete button. A factor is the whole coefficient of its load case; an empty field leaves the load case out of the combination. Add combination under the table adds an empty row with ULS.

Apply stays disabled while a row is incomplete, and one line under the table names what to correct: Enter a name for every combination., Give every combination its own name., Enter a factor of 0 or more. or Enter a factor above 0 for at least one load case of every combination. The combinations are saved with the other values of the dialog, as one undo step. When you delete a combination that a beam or column has selected, or remove the last of its load cases that the member has, the member's selection moves to the first combination it can show. How a user-defined combination is used in the checks is described in Chapter 15.

Source: spec/beam/design-code-member-combinations.md rules 6, 18, 22, 36–41; spec/beam/concrete-workspace.md rule 3.

Deflection and frequency limits

On the Deflection limits tab the Preset select offers Statiko default (L/400 · L/200 · 8 Hz) and Custom. The five fields are Span, instantaneous, Cantilever, instantaneous, Span, final and Cantilever, final, each written as L/ followed by the number you enter, and Frequency limit in Hz. A field you change is labelled with · Custom after its name. A source line names where the values come from: Statiko default, or a project criterion under EN 1990 A1.4 with EN 1993-1-1 7.2.1 for steel or EN 1995-1-1 7.2 for timber. The fields are disabled when no beam is selected.

A limit L/400 means the deflection may be at most the span length divided by 400; L/200 applies the same rule to a cantilever. How Statiko checks deflection and natural frequency against these limits is described in Chapter 21.

A concrete beam has one limit instead: a Deflection Limit picker with L/250, L/500 and Custom (a denominator above zero). The default is L/250. The same value shows in the card's Deflection row.

Source: spec/beam/design-code-member-combinations.md rules 5, 17; spec/beam/concrete-workspace.md rule 4.

One design code per project

A project has one National Annex for all its analyses. A beam stores only its own deflection and frequency limits. Every factor (γ, ψ, load durations, γM, KFI, service class, γ3, ksys) comes from the project's design code. When you change the design code, the change reaches every beam in every analysis: its checks, section properties, card and report. A file saved by an older version with a copy of the whole settings on a beam opens with that copy's limits as the beam's limits; its factors are dropped.

The country also decides how a steel beam's yield strength is found (Chapter 6). Concrete beams calculate with Eurocode recommended values, Custom values, Denmark (DS EN) and Serbia (SRPS EN); Sweden (SS EN) gives Concrete does not calculate under Sweden (SS EN): the Swedish National Annex to EN 1992-1-1 is not in Statiko yet.

Source: spec/beam/design-code-member-combinations.md rules 21, 22.

The Member card

The header reads Member · L 12.00 m, with the member length in your Length unit and display precision. You never type the length: Statiko computes it from the supports (Chapter 8). With a current result, the section class shows at the right, for example Class 1.

Choosing a product standard is a project edit like any other: Undo and Redo cover it, and the beam recalculates. A new open section takes EN 10025-2 for S235, S275, S355 and S450, and EN 10025-3 for S420 and S460.

Source: spec/beam/design-code-member-combinations.md rules 7–9, 12; spec/beam/steel-yield-strength.md rules 4–10.

The Load combinations card

The card holds one select. It lists None first, then this beam's combinations: ULS, then SLS, then Fire. Each option and the closed value carry a coloured ULS, SLS or Fire label before the name, for example STR/GEO - 6.10a, Characteristic, Quasi-permanent or Fire - 6.11a/b. The full name shows in the tooltip. The list widens to its longest item and closes when you click outside, press Esc, scroll outside it or resize the window.

The selected combination is shared: the drawing's reactions, the graphs and the checks all read it, and the status bar names it. Changing it is an edit, so the results become outdated and the calculation runs again for the new combination. No limit rows sit under the select; limits live in the design code.

Edit opens the Load combinations window, which opens as its own window like the Design code dialog. A beam without combinations shows only None, and Edit stays enabled. How the combinations are generated is described in Chapter 15.

After the Fire tab, the window has a Custom Combinations tab with the same table and rules as the Design code dialog (above). Its Apply saves the rows as one undo step and keeps the window open; it is unavailable while nothing changed or a row is incomplete. Close discards what you did not apply.

Every ULS, SLS and Fire row of the window has a Show in report box, ticked by default. Untick it to leave that combination out of the report's combination tables and per-combination diagrams for every beam of the project; a combination that governs a check is printed all the same (Chapter 14). The box is saved with the project and is one undo step. It never changes the calculation, which checks every automatic and user-defined combination. Deleting a user-defined combination drops its box in the same undo step.

Open load combination list
Figure 5.3 · The Load combinations select open: None, the ULS, SLS and Fire combinations with their coloured labels

Source: spec/beam/design-code-member-combinations.md rules 14–20, 43–45.

Chapter 6

Steel and timber cross-sections

The cross-section window is where a steel, timber or glulam beam gets its profile and grade. You pick a catalogue size or build a custom profile, and Statiko calculates the section properties and the steel cross-section class as you type. Nothing in the analysis changes until you press Apply. This chapter also explains how Statiko finds a steel beam's yield strength in each design country.

Opening the window

Open the window with Change section on the Member card, the ribbon command Cross-section or Model › Section catalogue…. It opens for the selected beam, on its section and grade. On desktop it is its own resizable window (at least 1240 × 800); while it is open you cannot edit the workspace behind it, and closing it is the same as Cancel. On a tablet or phone it is a full-screen page.

The title names the material and profile, for example Steel cross-section — IPE 220, Timber cross-section — … or Glulam cross-section — …. The subtitle says where the profile came from: Catalogue profile IPE 220 · Grade S235, Custom profile · started from IPE 220 · Grade S235 or Custom profile · not taken from the catalogue · Grade S235.

The tabs Steel, Timber and Concrete sit at the top of the window's left column on desktop, and under the title in a narrow window or on a phone; glulam is under Timber. A tab of another material switches the beam's material when you apply. The new material starts empty: Steel and Timber open the catalogue and show Choose a profile from the catalogue., and Apply stays disabled until you load a profile, which takes the default grade S235 or C24. The Concrete tab is described in Chapter 7.

Source: spec/beam/cross-section.md rules 1–4, 37.

Choosing from the catalogue

On desktop, and in any window at least 840 dp wide, the catalogue is always open in the left column under the tabs, as one expanding tree. On Steel it goes shape, family, size, for example I and H sections › IPE › IPE 220; on Timber it goes family, size. Each root row shows the shape glyph, the name and its number of sizes; family and size rows sit indented under their parent, and a size row shows only its designation. A root name too long for the column ends in an ellipsis and shows whole in a tooltip.

  1. The tree opens down to the profile in the window. Click a branch to open or close it.
  2. Or type in Search designations: every branch that holds a match opens. Clearing the search returns to the branches you had open.
  3. Click a size. It loads into the window, the Dimensions card shows its values, and the tree stays as it is.
  4. Check the properties and class, then press Apply.

The size in the window is highlighted, and every branch above it has a softer highlight, also while it is closed, so you can see where the size sits after you close the branches. The header Catalogue has two buttons: Show selected opens the branches down to the size in the window and scrolls it into view, and Collapse all closes every branch. Show selected is disabled while the window holds no catalogue size or saved profile, for example on a Timber tab that waits for its first profile. Create custom profile is pinned at the foot of the column.

In a window narrower than 840 dp, such as a phone, a narrow rail labelled Catalogue runs down the left edge on the Steel and Timber tabs. Click it to open the catalogue as a full-screen page. It opens on the sizes of the current family; the back arrow goes up to the families and shapes, and each size row shows the designation and its dimensions, each with its symbol, value and unit. A click on a size loads it and closes the page; Back closes the page without loading anything.

The Custom root comes first. It lists this project's saved custom profiles of the tab's material. Deleting one there removes it at once, without asking; beams that use it keep their own copy. If the catalogue cannot load, it shows Unable to load the profile catalogue.

Steel catalogue tree open down to IPE 220
Figure 6.1 · The catalogue tree with IPE 220 in the window: the header with Show selected and Collapse all, Search designations, the Custom root first, I and H sections › IPE open with the soft highlight and IPE 220 selected

Source: spec/beam/cross-section.md rules 3, 13–15, 32, 38–42.

The Profile view

On desktop the window has three columns over a footer with the status, Cancel and Apply. The left column holds the tabs and the catalogue. The centre column shows the drawing large, then for steel the class tiles, then the section properties. The input panel on the right has its own tabs: Section, Carbon and Fire for steel, timber and glulam. Section holds the Profile, Dimensions and grade cards; a catalogue profile shows its dimensions read-only. The panel opens on Section and keeps its tab while the window is open. Each column scrolls on its own. In a window narrower than 840 dp everything is one column.

Every profile also has the card Product stage carbon (A1-A3), on desktop in the Carbon tab, with Steel factor (timber and glulam: Timber factor) in kg CO₂e/kg and Factor source. A beam without a saved factor starts from Boverkets klimatdatabas 02.07.000: structural steel 3.15 (6000000150), sawn timber 0.08 (6000000007) and glulam 0.133 (6000000168). A line under the fields gives the member's mass (the section's mass per metre × length) and footprint, and the total. With a typed factor that is not usable it ends with Enter a named EN 15804+A2 GWP-total factor. and shows no total. Apply saves a typed factor with the profile in one Undo step; the report prints the same mass, factor, source, footprint and total at the end of 2.1 Materials.

Steel cross-section window for IPE 220 in S235
Figure 6.2 · The cross-section window for IPE 220 on desktop: the tabs and the catalogue tree on the left, the dimensioned drawing with the class tiles and the property groups in the centre, the Section tab with the Profile, Dimensions and Steel Grade cards on the right, and the footer Class 1 · S235

Source: spec/beam/cross-section.md rules 5–11, 33–35, 43, 44.

Custom profiles

  1. Load the profile you want to start from, or any profile.
  2. Press Create custom profile. The profile is copied into the editor with the name field Custom profile name and the line Started from IPE 220. (for example).
  3. Choose a shape in the shape list if you want another one. It starts from that shape's empty values and the line changes to Not taken from the catalogue.
  4. Enter the dimensions. The drawing and properties update as you type.
  5. Press Apply. The beam takes the profile and the profile is saved in the project.

Steel offers twelve shapes: I and H, tee, rounded tee, zee, angle, parallel-flange channel, tapered-flange channel, box girder, rectangular hollow, circular hollow, rectangular bar and circular bar. Flanged, tee, rounded tee and both channel shapes have a Rolled | Welded choice, default Rolled. Welded sets the radius fields to zero and hides them; Rolled needs a root radius above zero. A box girder is always Welded and may have a zero fillet radius; hollow sections, angles, zee and bars are always Rolled. Timber has one shape, the rectangle, with a Timber | Glulam choice; height and width stay when you change the type.

New profiles are named Custom profile, Custom profile 2 and so on. A name already used by a catalogue designation or another saved profile shows The name is already used by another profile. and disables Apply. With Custom steel grade you enter fy and E yourself, each above zero; the custom grade belongs to this beam only.

Applying under an unchanged name replaces the saved entry; a new name adds one. Each beam keeps its own copy, so editing a saved profile later does not change beams that already use it. A custom-profile beam is calculated, checked and reported like a catalogue beam; the report says Section properties calculated by Statiko from the custom profile geometry.

Source: spec/beam/cross-section.md rules 16–20, 23, 24, 30.

Validation, Apply and leaving

Properties and classes recalculate after every edit. While they calculate, the rows say so. A value the engine did not return reads Unavailable, never a number. Number fields accept digits, the minus sign and both decimal separators; spaces are ignored.

If a dimension is invalid, one message shows under its field, for example h must be greater than zero. The drawing then shows the last valid geometry dimmed with Section properties are unavailable, properties read Unavailable, and Apply is disabled. A focused dimension field highlights its dimension line in the drawing.

Apply is one project edit, undone in one step. Cancel, the close control, Esc and Android Back leave the analysis unchanged. If you have edited a custom profile, Statiko asks Discard changes? (The edited custom profile is discarded. The analysis stays as it was.) before loading another profile, switching tab or closing; choose Discard changes or Cancel. A failed Apply shows Unable to apply the selected profile. and keeps your selection. If another document opens or the beam changes, the window closes without applying.

Custom flanged profile with its height cleared
Figure 6.3 · A custom profile with h cleared: the message under the field in the Section tab, the dimmed drawing, Section properties are unavailable and Apply disabled

When you switch material, the beam keeps its fire inputs and its timber service class and load durations. It drops the carbon factor of the material it leaves, a custom steel grade and any concrete material and detailing.

Source: spec/beam/cross-section.md rules 12, 21, 22, 24–28, 37.

Yield strength per country

The fy in the Steel Grade card is the design yield strength the classification and every steel check use for this profile and grade. It depends on the project's design country:

Countryfy from
Denmark, SwedenReH of the product standard, EN 1993-1-1 3.2.1(1) a)
Eurocode, SerbiaEN 1993-1-1 Table 3.1, 3.2.1(1) b)
CustomTable 3.1 values; the steel report's material clause line notes “national choice not resolved”

In Denmark and Sweden fy is ReH of the thickness step that holds the governing thickness: EN 10025-2:2019 Table 6 for open sections, EN 10210-1 for hot-finished and EN 10219-1 for cold-formed hollow sections. A step includes its upper bound, so 16 mm counts as "≤ 16". The governing thickness is the thicker of web and flange for an open section, and the wall for a hollow section. For example, an S355 HE 300 B with a 19 mm flange has fy = 345 MPa in Denmark and 355 MPa under Eurocode.

EN 10025-3, EN 10025-4, and EN 10025-2 for S450, are not registered in Statiko. In Denmark and Sweden they give Table 3.1 values, and the steel report's material clause line names the standard, for example “EN 10025-3 not registered”. A custom open section takes its standard as a catalogue open section. A custom hollow section offers EN 10210-1 and EN 10219-1 and starts at EN 10219-1 (cold-formed, buckling curve c, the lower resistance). A custom steel grade keeps fy as entered in every country.

The class tiles show the class for pure compression and pure bending; combined compression and bending is not included. Effective Class 4 properties are not available in this version. The steel checks are described in Chapter 18.

Source: spec/beam/steel-yield-strength.md rules 1–3, 11–17; spec/beam/cross-section.md rules 9, 23, 31.

Chapter 7

Concrete beams

A concrete beam is modelled in two places. The concrete cross-section window holds the shape, the reinforcement, the stirrups, the materials, the cover and the serviceability inputs. The workspace inspector holds the shear angle, the T-flange shear inputs and the optional anchorage and lap details. This chapter walks through both, in the order you normally fill them in.

Creating a concrete beam

In the Create Beam Analysis dialog the Material field offers Steel (tagged EN 1993-1-1) and Concrete (tagged EN 1992-1-1); Steel is the default. Choose Concrete, set the Beam Length and create the beam.

A new concrete beam starts with a rectangular section h 600 × b 400 mm, concrete C30, reinforcement steel Y-550 with ductility class B, cover 30 mm, stirrups Ø8 at 200 mm, 2 Ø16 at the top and 3 Ø16 at the bottom, and the default detailing settings. Self-weight is on: its line weight is the section area times the concrete density.

You can also turn an existing beam into a concrete beam: open the cross-section window and choose the Concrete tab (Chapter 6). There is no concrete catalogue; the tab opens the concrete editor on Rectangular with its defaults.

Create Beam Analysis dialog with the Material list open
Figure 7.1 · The Create Beam Analysis dialog with the Material list open on Steel (EN 1993-1-1) and Concrete (EN 1992-1-1)

Source: spec/beam/concrete-workspace.md rules 1–2; spec/beam/concrete-section.md rules 1, 3, 6.

The concrete cross-section window

The title reads Concrete cross-section — Rectangular (or T, Circular) and the subtitle names the shape and concrete class, for example Rectangular · C30. The footer shows C30 · Y-550, or Invalid input, with Cancel and Apply. On desktop, and in any window at least 840 dp wide, the window has three columns. The left column holds the material tabs and the shape list, each shape with its glyph. The centre column shows the section drawing large, elevation A under it and the properties under that. The input panel on the right has the tabs Section (dimensions, longitudinal and shear reinforcement), Materials, Carbon, Durability and service and Fire. In a narrower window everything is one column.

Shape and dimensions

Choose Rectangular, T or Circular in the shape list, or in a narrow window in the choice above the dimensions. Changing the shape loads that shape's defaults and keeps your materials. All dimensions are in mm.

ShapeDimensions and defaultsReinforcement default
Rectangularh 600, b 400, cover 30Top 2 Ø16, bottom 3 Ø16, c 46; stirrups Ø8 at 200
Th 600, Flange width bf 800, Flange thickness hf 150, Web width bw 300, cover 30Flange 2 Ø16, web 3 Ø16, c 46; stirrups Ø8 at 200
CircularDiameter D 600, cover 308 Ø20 on a ring of radius 252 to the bar centres; ties Ø8 at 190

Longitudinal reinforcement

A rectangular section has Top reinforcement and Bottom reinforcement; a T section has Flange reinforcement and Web reinforcement. Each group is a list of rows with Count n, Size Ø and Axis distance c. A group with several rows adds the row count to its title.

A circular section has one ring with Count (a whole number, at least 3), Size and Radius r; a size change moves r by −ΔØ/2.

Shear reinforcement

Stirrup reinforcement is on by default, with Stirrups size and Stirrups spacing. Untick it and the size and spacing are disabled, no stirrup is stored and none is drawn. Cot(Θ) offers 1, 2, 2.5 and Custom (1 to 2.5); the default is 2.

Source: spec/beam/concrete-section.md rules 1–5; spec/beam/cross-section.md rule 5.

Materials

Concrete strength offers C12 to C90 and Custom; the default is C30 (C30/37). Cylinder compressive strength fck, Cube compressive strength fck,cube and Density are editable only for Custom. A class weighs 25 kN/m³, reinforced concrete by EN 1991-1-1 Table A.1 note 1, so its density is 25 000 / 9.81 = 2548.4 kg/m³. The older classes C8, C28, C32 and C100 open and show in older projects but are not offered.

Reinforcement steel offers Y-550, K-500 and Custom; the default is Y-550 with fyk 550 MPa and Es 200 000 MPa, editable only for Custom. Ductility class is A, B or C, default B.

The Carbon tab holds the card Product stage carbon (A1-A3) with Concrete factor in kg CO₂e/m³ and Reinforcement factor in kg CO₂e/kg, each with its Factor source. They start from the beam's saved factors, else from Boverkets klimatdatabas 02.07.000: the ready-mix row of the strength class (C12/15 and C16/20 have none and start empty), which follows the class while you have not typed a factor, and reinforcement 0.745 (6000000154). The lines under them give the concrete volume (gross area × length) and the longitudinal bars' mass, each with its footprint, and the total. Apply saves typed factors with the section.

Source: spec/beam/concrete-section.md rule 6.

Cover, durability and serviceability

Cover and durability

This group holds Concrete cover, Maximum aggregate size (default 16 mm), Exposure class X0 to XA3 (default XC1, Dry or permanently wet), Durability minimum cover cmin,dur and Execution deviation Δcdev.

When you pick an exposure class, Statiko sets cmin,dur and Δcdev for the project's National Annex and sets the cover to cnom = cmin,dur + Δcdev. An XF or XA class leaves all three unchanged.

National Annexcmin,dur tableΔcdev
DenmarkDS/EN 1992-1-1 DK NA Tabel 4.4N NA5 mm
Eurocode, Sweden, Serbia, CustomEN 1992-1-1 Table 4.4N, S4 (Eurocode recommended)10 mm

cmin,dur and Δcdev are standard value pickers: they offer the standard's values and Custom last, which opens a number field. A derived value shows its source, for example XC1 · Table 4.4N (Denmark XC1 · Table 4.4N NA), and a note naming the annex, Eurocode recommended or DS/EN 1992-1-1 DK NA. A stored value that matches no choice shows as Custom. A new concrete member starts from the XC1 values of the project's annex.

Serviceability

The Serviceability group is collapsed by default. It holds Cement class (Slow, Normal, Rapid; default Normal), Relative humidity (Inside 50 %, Outside 80 %, Custom 0–100; the default 70 % shows as Custom), Loading age t0 (default 28 d), Design age (50 years, 100 years, or Custom above t0; default 50 years) and Crack width limit wmax. wmax follows the exposure class from Table 7.1N (Denmark Tabel 7.1 NA), 0.4 mm for XC1; an XF or XA class leaves it. The deflection limit is set in the design code (Chapter 5).

Exposure class list in the concrete cross-section window
Figure 7.2 · The Exposure class list open in the Durability and service tab, each class from X0 with its description and XC1 Dry or permanently wet ticked

Source: spec/beam/concrete-section.md rules 7–9.

Properties, drawing and Apply

The properties are Effective depth d, Tension reinforcement area As,t, Compression reinforcement area As,c, Area of cross section A, and Iy and Iz. Statiko calculates them on every valid change; a value the engine does not give shows Unavailable, never 0.

The section drawing shows the outline to scale, the dashed cover line, the stirrup, the bars, the overall width and height, callouts such as 2 Ø16 and Ø8 stirrups / 200 c/c, a legend and Dimensions in mm. Elevation A below it shows the beam at its length with supports and point loads, the section cut, the stirrups and the bar lines with a dimension chain.

Each field is checked as you type. The messages are Must be greater than zero., Cover and stirrup must fit inside the section., for a T Web width must not exceed flange width., Flange thickness must be less than height. and Cover and stirrup must fit inside the web and flange., for a circle Enter a whole count of at least 3. and Cover, stirrup, bar and radius must fit inside the section., for rows Enter a non-negative whole count., and Cot(Θ) must be between 1 and 2.5. While a field is invalid the drawings stay at the last valid geometry, dimmed, with Last valid geometry and Correct the marked field to update the drawing., and Apply is disabled.

Apply writes the section, the materials and the detailing settings in one project edit, undone in one step. Cancel, close, Esc and Back leave the analysis unchanged; an edited draft asks Discard changes? first. There is no create, rename or delete for concrete profiles: the section belongs to the member.

Concrete cross-section window with section and elevation
Figure 7.3 · The concrete cross-section window on desktop: the material tabs and the shape list on the left, the section drawing with its callouts, the elevation with cut A and the properties in the centre, the Section tab on the right

Source: spec/beam/concrete-section.md rules 10–16.

Detailing inputs in the inspector

The inspector of a concrete beam has a Shear group with Cot(Θ) (1, 2, 2.5 and Custom 1 to 2.5), the same value as in the window.

On a T section the group adds the checkbox T-flange/web longitudinal shear, off by default. Switch it on to show T-flange · compression (1.0, 2.0, Custom 1.0 to 2.0), T-flange · tension (1.0, 1.25, Custom 1.0 to 1.25), each noted Eurocode recommended, and Asf / sf in mm²/m. It starts at 2.0, 1.25 and 0.

Tick Specify anchorage and lap details to open the Anchorage and Laps groups, for rectangular and T sections. A circular section has no detailing inputs.

Anchorage

Add anchorage adds a card for the first free bar and end, titled for example Bar 1 · Ø16 · Start. Each card has Force state (Tension, Compression), Bond condition (Good bond, Poor bond), End shape (Straight, Standard bend, Standard hook, Standard loop), Design stress σsd in MPa, Available length in mm, Mandrel diameter in mm (not for Straight) and Delete. A new card is Tension, Good bond, Straight, 0 MPa, 0 mm.

Laps

Tick Lap schedule is complete (including no laps) when the list is complete. Add lap adds a lap on the first bar. Each lap has the bar, start and end position, force state, bond condition, design stress, Bars lapped at section (< 25 %, 33 %, 50 %, > 50 %, Custom 0 to 100), Clear spacing between lapped bars in mm, Provided transverse reinforcement area in mm², the checkboxes Transverse reinforcement distributed in outer thirds, Required close-lap links provided and, under Compression, Compression-lap end bars provided, and Delete.

Every detailing field is validated by the engine; an invalid field shows its message, keeps the last valid input, and the checks show Invalid input. Each edit is one Undo step and the calculation runs automatically.

Shear group and an anchorage card for a concrete T beam
Figure 7.4 · A concrete T beam: the Shear group with cot θ, T-flange/web longitudinal shear ticked with its compression and tension choices, Specify anchorage and lap details ticked and the anchorage card Bar 1 · Ø16 · Start

Source: spec/beam/concrete-workspace.md rules 5–11.

Design code and checks

For a concrete beam the Design code card shows EN 1992-1-1 · Concrete, and the dialog shows γc, γs, αcc and αct with Eurocode recommended values, editable under Custom values. The deflection limit is L/250, L/500 or Custom, default L/250.

The checks column lists Bending +, Bending −, Shear, Stresses, Crack width, Deflection, Anchorage, Laps, T-flange longitudinal shear (T sections only) and Torsion, each with its clause. How they are calculated is described in Chapter 20; reading them is described in Chapter 12. Concrete fire design is in Chapter 13.

Source: spec/beam/concrete-workspace.md rules 3, 4, 12.

Chapter 8

Supports and lateral restraint

Supports decide where the beam is held and how, and they also decide its length: Statiko computes the member length from the first and last support or hinge, so you never type a span. This chapter covers the Supports section of the inspector, the timber bearing length, and the top flange restraint on the Member card, which changes how lateral-torsional buckling is treated.

Support cards

The Supports section sits after the Member card. Its header shows the sort button (Sort by position) and the number of supports. Each support is a card showing its glyph, a title, a restraint line, its position and a chevron.

KindRestraint line
Fixedw, φ restrained
Pinnedu, w restrained
Rollerw restrained
Hingemoment release
Freeno restraint

Here u is the axial displacement, w the vertical displacement and φ the rotation. A hinge is an internal moment release in the beam. A support whose restraints match none of the five kinds, for example from an older file, is shown as Custom with its own glyph and its restrained symbols; you cannot pick Custom yourself.

Supports section with three closed support cards
Figure 8.1 · The Supports section with three closed cards, A · Pinned, B · Roller and C · Free, and the dashed Add support row

Source: spec/beam/supports.md rules 1, 5–8, 16.

Adding and editing supports

Click a card to open it under its summary. Click the header again or press Esc to close it; there is no Done button. Only one card is open at a time across Supports and Loads, and opening a card selects that support in the drawing. Closing the card, or clicking the selected support again, returns the selection to the member.

An open card has two rows. The first holds the type picker and the x field. The second shows the kind and restraint line, with the bin button Delete support. Changing the kind keeps the position and recalculates.

  1. Click Add support at the end of the section.
  2. Choose Fixed, Pinned, Roller, Hinge or Free from the palette. With the keyboard, use ↑ and ↓ and press Enter.
  3. Type the position in x. Until it is valid, the card is a draft: its summary shows x —, it sits last, the status is Invalid input, and the calculation uses the model without it.
  4. Press Tab or Enter. The support takes its letter in position order.

Cards keep their order while you edit, so a card never jumps away from the cursor. Press Sort by position to reorder them by x. Tab moves through the open card, then into the next support card, and from the last support into the first load card; Shift+Tab goes back. On a phone a card opens without raising the keyboard.

Number fields accept digits, the minus sign and both decimal separators. Positions use the Supports unit from Settings › Units › Advanced when you have set one, otherwise your Length unit. Changing the unit changes only the display, not the stored value or the results. Undo and Redo cover every change to a support in the model. A draft is not in the model yet, so Undo and Redo leave it and its open card as they are.

Support B open with its type list
Figure 8.2 · Support B open with its type list: Fixed, Pinned, Roller, Hinge and Free

Source: spec/beam/supports.md rules 2, 3, 9–11, 13, 14, 17–19, 26, 27.

Length, origin and the minimum of two supports

The member length L is the position of the last support or hinge minus the position of the first, Free supports included. It shows in the Member card header and at the end of the dimension chain. Moving a support recomputes the length; it never moves another support.

x = 0 is always the left end. If your first support is at a positive x, Statiko adds a Free support at 0 for the left overhang. Its x is locked, and its card always says Added automatically. The beam starts at 0 m. Move the first support to change the overhang. The Free support at the right end stays editable.

A beam starts with two supports and always keeps at least two, the automatic Free support included. With two left, Delete support is disabled with the tooltip At least two supports are needed for calculation. If you delete the automatic left Free support, every support, hinge and load (both ends of a distributed load) shifts left so that the first support is at 0.

Source: spec/beam/supports.md rules 22–24, 29.

Support errors

A position error marks the card in the danger colour and shows the sentence once: under x on the open card, or in the issue line on a closed card.

An error that involves two supports, such as Hinge-Hinge element from 2.00 m to 4.00 m is not allowed., marks both cards. An unstable beam, Hinge amount exceeds the allowed amount according to the Equilibrium equation., marks the offending hinge cards. Too few supports shows At least two supports are needed for calculation. under the section header.

While any support error remains, the previous result is shown as outdated; it never shows a pass.

Source: spec/beam/supports.md rules 20–22, 25.

Timber bearing length

On a timber or glulam beam, each Fixed, Pinned and Roller support card has a second field under x: the bearing length lb (Bearing length), in the Supports unit, empty by default. Hinge and Free supports, and every support of a steel beam, have no such field.

Source: spec/beam/supports.md rule 30.

Top flange lateral restraint

The Member card has the checkbox Top flange laterally restrained under the Material and Product standard rows, for steel and timber beams. It is unticked for every new beam and for files saved before this option existed. Ticking it is a project edit: Undo and Redo cover it, and the beam recalculates. With the box ticked, the Member header meta reads Class 1 · top flange restrained, or top flange restrained without a current result.

Tick the box when a slab, deck or sheeting holds the top flange laterally along the whole length. Bottom-flange restraints, restraints at discrete points and restraint over part of the length are not available in this version.

Which combinations it covers

A ULS combination is covered when the box is ticked and no moment along the beam is negative, so the top flange is in compression everywhere. A combination with a hogging moment anywhere, over an internal or fixed support, on a cantilever or under uplift, is not covered, and lateral-torsional buckling is checked for it as usual. The LTB model treats every support that holds a translation as a fork support, holding lateral displacement and twist.

MaterialCovered combination
SteelLTB is Not evaluated (EN 1993-1-1 6.3.2.1(2)); no Mcr, χLT or Mb,Rd. The card is neutral and reads Top flange laterally restrained: not susceptible to lateral-torsional buckling (EN 1993-1-1 6.3.2.1(2)). Bending keeps its bending and warping interaction.
TimberLTB stays evaluated with kcrit = 1.0 (EN 1995-1-1 6.3.3(5)). The card adds Top flange laterally restrained: k_crit = 1.0 (EN 1995-1-1 6.3.3(5)).

Not evaluated is its own state and is never counted as a pass. The LTB card shows the worst state first, then the checked combination with the highest utilisation; only when every ULS combination is covered does it show Not evaluated. If a combination is not covered, the card adds The top flange restraint does not cover followed by the combination and the bottom flange is in compression.

In the check details the Restraint line reads Top flange laterally restrained or None. The steel report states the declaration in its structural system section and lists it among the limitations in the appendix. How Mcr and the buckling checks are calculated is described in Chapter 17.

Steel beam with the top flange laterally restrained and Lateral Torsional Buckling Not evaluated
Figure 8.3 · A simply supported IPE 220 with Top flange laterally restrained ticked: the Member card reads Class 1 · top flange restrained, the Lateral Torsional Buckling card is neutral with the not-susceptible sentence, and the Moment header shows no Mcr

Source: spec/beam/lateral-restraint.md rules 1–16.

Chapter 9

Loads and self-weight

The Loads section lists every characteristic load on the beam: point loads, moments and distributed loads. Each load has a load action, which tells the EN 1990 combinations which partial and ψ factors apply. The section also holds the self-weight switch. This chapter shows how to add and edit loads, where a load acts over the section height, and what the load errors mean.

The Loads section and self-weight

The Loads section follows Supports in the inspector. Its header shows Sort by position and the number of loads.

Under the header, tick Include self-weight in G to add the beam's own weight to the permanent action G. A line then shows Characteristic self-weight: and the value from the current section, in your force-per-length unit. If the section cannot be resolved, a reason shows instead of the value. A new concrete beam starts with self-weight on; other new beams start with it off.

Source: spec/beam/loads.md rule 1; spec/beam/concrete-workspace.md rule 2.

Reading a load card

Load cards look and behave like support cards: a neutral border, lighter when closed and stronger when open or selected. Only one card is open at a time across Supports and Loads; Esc closes it.

Values have no plus sign; negative values use the true minus −. Trailing zeros are dropped. A new load shows — for each value until you enter it.

Loads section with self-weight and three load cards
Figure 9.1 · The Loads section: Include self-weight in G with the characteristic self-weight, a sloped distributed load, a point load, a moment and the dashed Add load row

Source: spec/beam/loads.md rules 2–7.

Adding and editing loads

  1. Click Add load at the end of the section.
  2. Choose Point, Moment or Distributed. The new load takes the action Dead Load (G), its card opens and the first field has focus.
  3. Choose the load action in the select next to the type picker.
  4. Enter the values, each on its own row: for a point load x and F; for a moment x and M; for a distributed load x1, x2, q1 and q2.
  5. Press Tab or Enter. The calculation runs automatically.

Until its fields are valid, a new load is a draft: it sits last, the status is Invalid input, and the calculation runs without it. Changing the type keeps the action and the start position and clears values the new type does not have. The bin button Delete load sits on the card's last row.

The load action select lists Dead Load, the imposed-load categories A to H (for example A Domestic, residential areas, B Office areas, H Roofs), Wind Load, Snow Load and Custom Load, each with its glyph. Long names end with an ellipsis; the full name is in the tooltip. How each action enters the combinations is described in Chapter 15.

Cards keep their order while you edit. Sort by position orders them by x, or x1 for distributed loads, and is one Undo step. Tab moves through type, action, values, the application point buttons, ez (only when unlocked), ey and Delete, then into the next load card; after the last load it reaches Add load. On a phone a card opens without raising the keyboard.

Number fields accept digits, the minus sign and both decimal separators. An unfinished entry such as - or 1, keeps its text, marks the card and shows Enter valid numbers before calculating. Positions, forces, line loads, moments and self-weight use the Loads unit from Settings › Units › Advanced when you have set one.

Source: spec/beam/loads.md rules 8–12, 19–22, 25, 27.

Application point and eccentricity

Point and distributed loads have an application point that says where over the section height the load acts. The card shows Top, Middle, Bottom and a lock on one row, then the vertical eccentricity ez (ePz for a point load), then the lateral eccentricity ey. Moments have no application point.

The tooltips read Attack Point Top, Attack Point Middle, Attack Point Bottom, Enable custom load attack point for LTB and Disable custom load attack point for LTB: the application point matters for lateral-torsional buckling (Chapter 17).

A new point or distributed load starts locked at Top. When you change the section, every locked load keeps its preset and takes the new height; your own values stay. If the section fibre heights cannot be found, the presets and lock are disabled with a reason on the card, such as Application point presets require a valid section., and ez keeps its value. An older distributed load with different start and end eccentricities shows Start and end eccentricities differ. The start values are shown; editing an eccentricity applies it to both ends.

Open point load card
Figure 9.2 · An open point load: x and F, the three application point buttons with the lock, ePz disabled, ey and the delete button

Source: spec/beam/loads.md rules 13–17.

A moment on a hinge

When a moment sits on a hinge (within 1 mm of its position), the card shows Acts on with Left of the hinge and Right of the hinge, default Right, and the hint The results differ by side. Choose the side the moment is applied to: each side belongs to a different part of the member. Moving the moment off the hinge hides the choice and keeps your side.

Source: spec/beam/loads.md rule 18.

Load errors and axial loads

A load must lie between the first and the last support, hinges and Free supports included. Otherwise the card turns to the danger colour and shows Load positions must be within the member bounds. under the position. A distributed load whose end is not after its start shows The end position must follow the start position. The status is Invalid input and the drawing marks the load.

An axial load from an existing file shows as a read-only card with its action, position and force and Axial loads are not editable yet. You cannot add axial loads in this version.

Source: spec/beam/loads.md rules 23, 24, 26.

Chapter 10

The structural system drawing

The Structural system drawing shows the beam as you have modelled it: the member, its supports, the characteristic loads, the support reactions of the selected load combination, and the dimension chain with the computed length. Use it to check your input at a glance and to read the reactions. The drawing never changes the model; you edit supports and loads in the inspector.

The panel

The panel sits at the top of the workspace, under the header Structural system, with the result graphs below it. It has a fixed height and a plain dark canvas without a grid. The X and Z axes sit at the bottom left.

The drawing and every result graph share one horizontal scale with the same margins, so a support, a load position and a graph station at the same x line up at every window width. Dashed vertical guides run down from each support and hinge to the dimension line.

Structural system drawing of a simply supported beam with a current result
Figure 10.1 · A steel beam pinned at 0 and on a roller at 6 m with a distributed and a point load and a current result: load badges, reaction badges on the guides, the dimension chain ending L 6.00 m and the axes

Source: spec/beam/structural-system-drawing.md rules 1–6.

Member, supports and loads

The member is drawn with a dashed reference axis and split into parts at internal hinges. When the Member card is selected, all parts glow light blue.

SupportGlyph
Fixed at an endOne bold line through the beam end with five thin hatches on the outer side
Fixed inside the spanTwo bold lines across the beam with five hatches between them
Pinned, RollerTriangles on hatched ground
HingeA ring
Free endA square

Loads sit above the member in the load colour: point loads as arrows, moments as arcs, distributed loads as a filled area with arrows. A distributed load that changes sign is drawn as one straight line across the member with a fill triangle on each side of the zero.

The drawing always shows the characteristic loads you entered. It never multiplies a load by a partial factor; the factored design loads appear only in the PDF report's figure (Chapter 14).

Source: spec/beam/structural-system-drawing.md rules 7–10, 26.

Values and reactions

Each force value sits in a small badge with a thin grey outline. A load badge has a short red bar before its value; a reaction badge has its light-blue glyph there instead. Load and reaction values show two decimals.

Each support shows one badge per non-zero reaction component of the selected combination: vertical force, moment and torque. Zero components are not drawn. The badges sit below the member, centred on the support's guide, stacked force, moment, torque. A badge that would overlap a neighbour drops one row. In the sign convention, a positive force points up and a positive moment turns anticlockwise. Tables and the report keep the signed components with their axis system named.

The reactions belong to the combination selected on the Load combinations card (Chapter 5); change the combination and the reactions change with it.

Source: spec/beam/structural-system-drawing.md rules 11–14, 18.

Dimensions and crowded labels

Positions live on the dimension chain under the beam: the segment lengths between supports and hinges, then L and the member length. No node names or positions are written on the member. Each dimension label is centred on its segment; if it overlaps its neighbour it moves to the other side of the line, and if neither side has room it moves past the end of the chain with a dotted leader. Where the drawing ends first, as on a phone with large text, the label moves in from the right edge to the first free row above, so it is always shown whole.

When load badges still overlap after placement, they fold into one cluster badge that reads the front value, a bar and the number of hidden labels, for example 5.00 kN | +4. The front shows a point force first, then a distributed load, then a moment, and the largest value within that type.

  1. Hover the cluster on desktop, or tap it on a touch screen. A list opens with each clustered load's type, value and x, sorted by x.
  2. Hover a row to highlight that load in the drawing.
  3. Click a row to select that load; its card is selected with it.

Zooming in or widening the window splits clusters again when the badges fit. Because the panel height is fixed, labels get their space first and the beam fits in the rest, mainly by shorter load arrows; the graphs below never move.

Cluster badge with its list of hidden loads
Figure 10.2 · The cluster badge 5.00 kN | +4 with its list of the loads it holds, sorted by x

Source: spec/beam/structural-system-drawing.md rules 16–18a.

Selection and errors

Select a support or load on its card or in the drawing. The selected element takes a stronger shade of its own colour, and every other element fades to about 40 %. The card and the drawing always agree. Hovering an element, its card or a cluster row strengthens only that element, without fading the rest.

A support or load with an input error is drawn in the danger colour, and its card carries the danger mark. A support in error has a red outline. An invalid load is drawn in danger red with a dashed outline and a small warning icon at its anchor. The unstable hinge of an unstable beam is drawn in the danger colour. An error that belongs to the whole section, such as too few supports, marks no element.

Point load past the last support drawn in red
Figure 10.3 · A point load past the last support: drawn in red with a dashed outline and a warning icon, and no reactions

Source: spec/beam/structural-system-drawing.md rules 19–21a.

Calculation states

StateWhat you see
Current resultMember, supports, loads, reactions and dimension chain
First calculation runningNo reactions; a progress line runs on the panel edge
Recalculating after a changeThe previous reactions, dimmed, and the progress line
Not calculated (no loads)The system without loads or reactions
Invalid inputNo reactions; the invalid element in the danger colour

Reactions appear only for a current result, or for a previous result shown as outdated. The drawing has no Design loads view in this version.

Source: spec/beam/structural-system-drawing.md rules 15, 25, 29, 30.

Part III

Reading the results

Chapter 11

Result graphs

The result graphs show how the beam carries its loads: shear, moment, rotation, deflection, torsion and the natural vibration mode, plotted along the member for the load combination you have selected. Every curve is read from the same calculation result that the checks and the PDF report use, so what you see on the graph is exactly what the checks verify. This chapter explains the two graph views, what each part of a graph means, how the cursor readout works and what the graphs show while a calculation is running or cannot run.

Graph list and Dual-axis graph

The graphs fill the canvas of the beam workspace, under the Analysis tab. The canvas toolbar switches between two views:

The same choice is in the View menu: View › Graph list and View › Dual-axis graph follow the toolbar and the toolbar follows the menu. On a phone both views are in the Results tab, which keeps the canvas toolbar with Dual-axis and shows the Graph list in Tabs by default (Chapter 4).

Source: spec/beam/graph-list.md rules 15–18; spec/beam/dual-axis-graph.md rule 14.

The six graphs

Graph list shows six graphs, always in this order:

GraphSymbolDefault unit and decimalsShown by default
ShearVkN, 2 decimalsYes
MomentMkNm, 2 decimalsYes
Rotationθmrad, 2 decimals (rad or ° also available)No
Deflectionδmm, 1 decimalYes
TorsionTmoment unit (torque) or rotation unit (twist)When the beam carries torsion
Natural Frequencyf1Hz, 2 decimalsFor an SLS combination

Units follow Settings › Units (see Chapter 24). Rotation is off at first; tick it to see it.

The selected load combination drives every curve, deflection included. With None selected the graphs show the characteristic actions with unit factors. Changing the combination counts as an edit: the curves go outdated for a moment and then show the new combination.

Some graphs only make sense in some cases, so the app never draws an empty or meaningless plot. Instead the graph's checkbox or tab stays visible, greyed out, with its reason:

Source: spec/beam/graph-list.md rules 1–7, 12, 13, 24.

Stacked and Tabs

In Graph list the two icons at the right end of the toolbar choose the layout:

View › Stacked / Tabs shares this choice. In the Dual-axis graph the layout icons are hidden and the menu item is disabled with “Choose Graph list to change its layout.”

Graph list with Shear and Moment plots
Figure 11.1 · The Graph list, Stacked, for a ULS combination: the checkbox row with Rotation unticked, the Natural Frequency reason, and the Shear and Moment plots with their badges and Mcr

Source: spec/beam/graph-list.md rules 15–18.

Reading a graph

Each graph is a flat panel on the workspace background with a thin line above it. Inside it you see:

Values have no plus sign; negative values use the true minus “−”.

Two graphs add a reference:

The Rotation graph includes both sides of a hinge.

The cursor readout

Move the pointer over a plot. A hollow ring appears on the curve at that position with a value badge beside it, and a small badge on the x axis reads x = <position>. The status bar never shows cursor values; it always shows the calculation state.

Source: spec/beam/graph-list.md rules 3–5, 8–12.

Controls in the graph headers

Four graphs carry extra information or controls in their header.

Torsion: Torque or Twist

A Torque / Twist switch chooses what the Torsion graph shows. Torque is the default. Twist plots the angle of twist ϕ along the beam in the rotation unit, with ϕmax and ϕmin badges. The choice lasts for the session and is not saved in the project file. The Dual-axis graph uses the same choice.

Natural Frequency: Mode and Animate

The Mode picker offers Mode 1 up to the number of computed modes, at most five. The badge shows that mode's frequency fn. Each new result returns to Mode 1. Tick Animate to see the shape swing: it repeats every two seconds whatever the frequency, while the axis stays fixed. Animate is off at first and lasts for the session.

Moment: Mcr

The Moment header shows Mcr = <value>, the elastic critical moment the lateral-torsional buckling check computed for the moment distribution of the selected combination (see Chapter 17). It is shown only when the check computed it; while calculating, or when it is not available, the header has no Mcr.

Deflection of timber and glulam: uinst and ufin

For a timber or glulam beam with a characteristic SLS combination selected, the Deflection graph adds a dashed curve ufin, the final deflection the final deflection check verifies, beside the instantaneous uinst. The header reads uinst = … / ufin = … and the cursor badge shows both. Other combinations and materials show uinst only.

Moment, Deflection and Natural Frequency plots for SLS
Figure 11.2 · An SLS combination with the pointer over Deflection: the hover ring and badges, the L/400 limit line, and Natural Frequency with the Mode picker and f1

Source: spec/beam/graph-list.md rules 25–32.

The Dual-axis graph

The Dual-axis graph draws two quantities on one plot with one shared zero line, a left ruler for the left curve and a right ruler for the right curve, each with its unit above it in the curve's colour. Use it to see, for example, where the shear crosses zero under a moment peak.

A row below the toolbar holds up to three selects; a preset shows only Compare:

A preset or quantity without data stays in the list, disabled with the same reason as in Graph list, for example Shear + Torsion on a beam without torsion. The deflection ruler names the selected combination and shows the limit line only for an SLS combination. Your choice is kept for each analysis while the project is open; it is not saved in the project file.

Both curves get extreme badges and, under the pointer, a ring and a value badge each, sharing one x badge.

Dual-axis graph comparing moment and shear
Figure 11.3 · The Dual-axis graph, Compare = Moment + Shear: the kNm ruler on the left, the kN ruler on the right and the two-value cursor readout

Source: spec/beam/dual-axis-graph.md rules 1–11, 15.

While calculating and when there is no result

Statiko calculates automatically after every valid edit; there is no Calculate button. The graphs tell you which state the result is in, with the same words as the status bar:

StateGraph listDual-axis graph
First calculationThe empty frame (zero line, x axis, guides), a circular indicator and “Calculating…”“Calculating…”, no curves
Calculating with a previous resultThe previous curves dimmed, a progress line on the panel edge“Calculating…”, no curves
OutdatedCurves dimmed, “Results outdated”“Results outdated”, no curves
Invalid inputCurves dimmed, “Results outdated”, and “Enter valid numbers before calculating.” when a field holds an unreadable number, otherwise “Invalid input. Review the beam geometry and load.”The same sentence, no curves
Not calculated, Unstable, Failed, Unsupported, UnavailableThe state's sentence, for example “The beam is not stable with these supports and cannot be calculated.”, and no curveThe same sentence, no curves

Source: spec/beam/graph-list.md rules 19–23; spec/beam/dual-axis-graph.md rules 12–13; spec/beam/workspace-shell.md rules 20–25.

Chapter 12

The checks column and check details

The checks column tells you whether the beam passes its Eurocode verifications. Each check is a card with the engine's utilisation and verdict, and a summary above the cards names the governing check. Open a card and you see how the result was reached: the governing combination, the equations with your numbers and every value used. The derivation on screen is the same one the PDF report prints. Statiko shows the engine's numbers and verdicts; the column itself decides nothing.

Where the checks are

In a large desktop window the checks sit in a 320 dp column on the right of the workspace. In an expanded window they follow the graphs in the scrolling centre column as a grid of cards, at least 220 dp wide each. In compact and medium windows the list shows alone, and a card opens its check full width with the Checks back button. On a phone they are in the Checks tab (see Chapter 4).

At the end of the column the Report button opens the PDF export (see Chapter 14). It is enabled for current and outdated results; otherwise it is disabled with “No current result is available for a report. Calculate first.”

Steel checks column with the governing summary and seven check cards
Figure 12.1 · The checks column of a steel beam: the governing summary, seven cards with Torsion Not evaluated and a failing Displacements card, Eigenfrequencies marked Governing, and the Report button

Source: spec/beam/checks-column.md rules 21, 22.

Which checks are listed

The list depends on the material and never changes length: the same cards appear while calculating, when current, outdated or failed, so nothing jumps around as you edit.

SteelTimber and glulam
Bending Utilisation (Class n) · EN 1993-1-1 6.2.5Bending · EN 1995-1-1 6.1.6
Shear Utilisation · EN 1993-1-1 6.2.6Shear · EN 1995-1-1 6.1.7
Shear Buckling Resistance · EN 1993-1-1 6.2.6(6)Bearing · EN 1995-1-1 6.1.5
Lateral Torsional Buckling · EN 1993-1-1 6.3.2Torsion · EN 1995-1-1 6.1.8
Torsion Utilisation · EN 1993-1-1 6.2.7Lateral Torsional Buckling · EN 1995-1-1 6.3.3
DisplacementsDisplacements (uinst and ufin in one card)
Eigenfrequencies · EN 1993-1-1 7.2.3 / EN 1990 A1.4.4Eigenfrequencies · EN 1995-1-1 7.3.3 / EN 1990 A1.4.4

There is no separate bending-and-shear card for steel: the high-shear interaction is the last row of the opened Bending check. A timber or glulam beam with fire input adds Fire verification at the end (see Chapter 13). Concrete beams have their own list, described in Chapter 7 and Chapter 20.

Torsion is always listed. Without torsion it reads Not evaluated with “No torsion: all loads act in the plane of the beam through the shear centre.” Shear Buckling Resistance reads Not relevant when the web does not need it. Lateral Torsional Buckling reads Not evaluated only when the engine gives a reason, such as a declared top flange restraint (see Chapter 8).

Source: spec/beam/checks-column.md rules 1–6; clauses from resources notation BeamCheckNotation.kt.

Reading a check card

Each card shows the check's title and clause, the utilisation as a percentage with one decimal and the ratio η beside it, for example 86.2 % and η = 0.862, and the verdict word Pass or Fail.

The bar under the numbers has a marker at 100 %. A passing fill runs green up to the value; a failing fill is red and grows stronger past the marker. Above 100 % the scale stretches so the marker stays inside the card. Green and red appear only with a real Pass or Fail, and always with the word.

The steel and timber Lateral Torsional Buckling cards also show Mcr for the check's governing combination; Bending and LTB cards show the warping moment Mw,Ed and the minor-axis moment Mz,Ed when the engine reports them.

The governing summary

Above the cards a line counts the results, “<n> passed · <n> failed · <n> other”, and names the governing check with its combination. The governing check is the evaluated check with the greatest utilisation, and its card carries the Governing mark. It can be an SLS check such as Eigenfrequencies. While calculating, the summary shows “Calculating…” and no verdict.

Every check is verified over all of this beam's combinations, whichever combination the Load combinations card shows. With None selected the cards show the same governing results as with any combination selected; only the graphs change, and the Moment graph then shows no Mcr.

Source: spec/beam/checks-column.md rules 7–13, 19.

When a check has no ratio

Statiko keeps every kind of “no result” distinct, so a missing check is never mistaken for a pass.

StatusWhat the card shows
UnsupportedNeutral, no ratio or bar, the reason, e.g. “The web slenderness requires a shear buckling check (EN 1993-1-5 section 5), which is outside the supported scope.”
UnavailableNeutral with its reason, e.g. “Mode 1 natural frequency is not available.”
Invalid inputWarning colour, no ratio
Failed calculationError colour, no ratio
Not evaluated / Not relevantNeutral with a one-sentence reason; counted under “other”, never as a pass
Outdated“Outdated”, the previous ratio dimmed, no green
Calculating, first runThe real cards with placeholder values and an empty bar

Other reasons you may meet include “Support B has no bearing length.” (naming the support), “The beam carries an axial force; the beam checks cover beams without axial force.”, “Statiko does not cover the Swedish National Annex crack factor for timber shear.” and “No load combination applies to this check.” When the whole analysis has failed or is unsupported, every card shows that sentence instead of a ratio.

Source: spec/beam/checks-column.md rules 14–18 and Strings.

Opening a check

Click a card to open its derivation. On desktop and tablets two tabs sit over the centre, Analysis and Verification. The card opens under Verification, named Verification · <check>; the drawing and graphs wait under Analysis. The Verification view lists every check of the beam in the list's order, each as its compact card followed by its derivation, and scrolls to the one you clicked. The checks column stays in place with the opened card outlined. With nothing opened, Verification reads “Choose a check to see its derivation.” Click the Analysis tab to go back.

On a phone the card opens full width with a Checks back button above the title; Android Back closes the check before leaving the workspace.

Bending check opened in the Verification tab
Figure 12.2 · Bending Utilisation opened in the Verification tab: utilisation and Pass, MEd at its position, the steps, the high-shear row and the value table

Source: spec/beam/check-details.md rules 1–4, 25.

What the derivation shows

From top to bottom an opened check shows:

  1. the title, clause, utilisation, verdict word and bar, exactly as on the card;
  2. the governing combination, with the governing position where the engine gives one, for example “MEd at 2.40 m”; a section check without a combination says so, for example “Section check for IPE 220. No load combination.”;
  3. for a concrete Bending + or Bending − check, the flexure figure of the report: the section, the strain and stress diagrams and the detail of the compression zone, with x, the stress block and the forces Cc, Cs and Ts; in a narrow view it scrolls sideways;
  4. the derivation steps: the governing inequality with its equation number, the resistance formula, the formula with your values substituted, and the utilisation line;
  5. the value rows, a tight table of symbol and value with unit.

The equations are those of the method the engine used. Steel Bending uses Wpl, Wel,min or Weff according to the section class, and ends with the high-shear row: VEd, Vpl,Rd, ρ and My,V,Rd when the reduction applies, or “VEd ≤ 0.5 Vpl,Rd (6.2.8): no reduction”. Lateral Torsional Buckling shows Mcr, αLT, λ̄LT, ΦLT, χLT and Mb,Rd with γM1. Eigenfrequencies shows f1, flim (“limit from project settings”), the mass basis and η = flim / f1. Timber Bending begins with Service Class and Shortest load duration, the two inputs that set kmod, then σm,y,d and fm,d. The methods themselves are explained in Chapter 18 and Chapter 19.

Every number comes from the engine result or your inputs; the screen only formats it. A value the engine does not give reads Unavailable. Unsupported, invalid and failed checks show only the verdict word and the reason, with no equations. While the first calculation runs, the view reads “Equation values are not available until a calculation finishes.”; when outdated, the previous derivation stays with the Outdated word.

Source: spec/beam/check-details.md rules 5–11, 14–21, 23, 24.

Chapter 13

Fire design: inputs and checks

Fire design verifies that a steel, timber, glulam or concrete beam keeps enough resistance for the required fire period. You choose the required resistance and how the beam is exposed; Statiko takes the design effects from the fire combinations it already generates (EN 1990 6.11b) and runs the simple Eurocode method for the material. This chapter shows where the fire inputs are, what each one does and how to read the result. How the methods calculate is explained in Chapter 22.

Where the fire inputs are

The fire inputs live in the cross-section window, in the same draft as the profile. On desktop they are in the input panel's Fire tab, with the fire results under them; in a narrow window they sit under the profile. The region is titled Steel fire design (EN 1993-1-2), Timber fire design (EN 1995-1-2) or Concrete fire design (EN 1992-1-2).

Fire inputs belong to the beam, not the profile: choosing another profile keeps them. Inputs for another material stay dormant and come back if you switch back. A fire edit is a normal project edit with Undo and Redo, it is saved in the project file, and the beam recalculates automatically.

Source: spec/beam/fire.md rules 4–11.

Required fire resistance and exposure

Required fire resistance offers None, R30, R60, R90, R120 and Custom (minutes), which shows Custom fire resistance (min). None is the default for new beams and for older files: the beam then has no fire result, no fire card and no fire verdict. An empty or zero custom time gives “Enter the required fire resistance time (minutes).”

For steel and timber, Fire exposure offers Four sides (all around), Three sides + slab on top (steel: “… slab on top flange”) and Custom faces, which shows Left, Top, Right and Bottom under Custom exposed faces. Picking a preset ticks its faces; changing a face switches to Custom. Steel starts on four sides, timber on three.

Each fire combination is verified with its own design effects and the result names the governing one. You never type a fire moment or a reduction factor.

Source: spec/beam/fire.md rules 2, 12–16, 19.

Steel

The region opens with “μ0 = E_fi,d / R_fi,d,0 (EN 1993-1-2). The η_fi = 0.65 shortcut is not used.” and a notice on how far the section is supported: I and H sections have the full path, hollow sections are supported for heating, other open sections are partial, and circular hollow, round bar, angle and zee sections read Unavailable with the inputs disabled but kept.

Under Fire verification two methods sit side by side. The Critical temperature method shows μ0, κ1, κ2, γM,fi with its source, θa,cr, Am/V, the steel temperature at the required time, the margin θa,cr − θa and the verdict. The Resistance method shows Mfi,t,Rd, Vfi,t,Rd and Mb,fi,t,Rd with χLT,fi, each with its utilisation. The Steel fire verdict is the worse of the two, so neither can hide a failure.

Steel results appear in the cross-section window and in the report, and with fire input the steel checks list ends with a Fire verification card (EN 1993-1-2 4.2.3, 4.2.4) with the same note as the timber card; opening it shows the fire derivation and verdict in the check details. A Custom design country reads “Custom National Annex steel fire factors are not verified in Statiko.”

Steel cross-section window with R60 contour protection and both fire methods
Figure 13.1 · An IPE 220 at R60 with contour protection: the fire-exposed perimeter and the contour on the drawing, and the Fire tab scrolled below the protection values to Fire verification with the critical temperature method, the resistance method and the Steel fire verdict

Source: spec/beam/fire.md rules 20–35.

Timber and glulam

Timber and glulam use the reduced cross-section method, for rectangular sections and Eurocode recommended values only. Fire cladding is Unprotected or Gypsum plasterboard type A, which needs Cladding h_p.

The result shows four groups: Parameters (kmod,fi, dchar,n, def, bfi, hfi and the Charring phase), Design capacities (fm,d,fi, fv,d,fi), Cross-section checks (bending and shear ratios) and Stability checks (σm,crit, λrel,m, kcrit and the buckling ratio). The overlay draws the charred layer and residual section, and the cladding solid while effective and dashed after its fall-off time.

With fire input, the timber checks list ends with a Fire verification card (EN 1995-1-2 4.2.2) noting “Fire verification is the fire design situation; it is not part of the governing check.”

Timber checks column ending with the Fire verification card
Figure 13.2 · A C24 45×220 beam at R30 behind gypsum plasterboard type A: the timber checks column ends with the Fire verification card (EN 1995-1-2 4.2.2) and its note

Source: spec/beam/fire.md rules 36–43.

Concrete

Concrete uses the tabulated data of EN 1992-1-2 5.6 from the beam's own section, bars and supports. The region holds Fire exposure, Three sides + slab on top (default) or Four sides (all around), and the required fire resistance. There are no other fire fields.

The result compares the width b with bmin and the axis distance a with amin, and names the table (Table 5.5 · simply supported or Table 5.6 · continuous beam), the column and the Table row; a custom time uses the next row up. Each requirement reads OK or Fail.

The tables do not cover every case, and Statiko says so rather than guessing. These read Unavailable with their reason: a cantilever or a single span with a fixed end, four-sided exposure, a circular section, more than R240, concrete above C50/60, concrete above 2600 kg/m³, and the National Annexes of Denmark, Serbia, Sweden or a Custom country. A continuous beam at R90 or more that meets the width b and axis distance a reads Unavailable, because the top reinforcement rule over the supports is not verified; one that fails b or a reads Fail. Table 5.7 (R120 and above) is not verified either.

Concrete results appear in the cross-section window and the report, and with fire input the concrete checks list ends with a Fire verification card (EN 1992-1-2 5.6) with the same note as the timber card; opening it shows the tabulated derivation and verdict in the check details.

Source: spec/beam/fire.md rules 44–50.

Fire in the report

With fire input, the report's fire chapter (5.6 for steel, timber and glulam, 5.2 for concrete) prints at every detail level: the method, the section figure with its fire overlay, the inputs, the results and the verdict; steel prints both methods and the governing verdict. Without fire input the chapter keeps its one sentence, such as “Fire design according to EN 1993-1-2.” The Summary has one fire row, outside the governing check, and Basis of design prints the fire protection requirements you typed in the export form. A fire result that is Unavailable, Invalid or partial cannot be deselected in Custom. See Chapter 14.

Source: spec/beam/fire.md rules 51–55.

Chapter 14

The report and the PDF

The report turns your calculated beam into an A4 PDF that a checker can read: the basis of design, the beam and its loads, the internal forces, every check with its clause and derivation, and the verdict. You fill in the project details once, choose how much detail to print, preview the pages exactly as they print, and save or print them. The report prints the engine's values, clauses and verdicts from the same result the screens show; it computes nothing of its own.

Opening the report

Open the export view in any of these ways: Report in the ribbon, File › Export PDF report…, Ctrl+P, or the Report button at the end of the checks column.

Preview and Export PDF work only for a complete result of the current input. While results are missing, outdated, calculating or invalid, both are disabled and the view shows “No current result is available for a report. Calculate first.” You can still fill in the form. As soon as the automatic calculation finishes, both buttons enable without reopening the view.

Source: spec/beam/report.md rules 1, 2; spec/beam/workspace-shell.md rule 18; spec/beam/phone-and-tablet.md rule 22.

The export form

The export view opens as its own window with one form column. Its footer holds Export PDF, Preview and Cancel; Cancel and Close return to the beam and keep what you typed.

GroupFields
Project InfoName, Number, Title, Address, Initials, Date, Project Description, Prepared by, Checked by, Revision
Project RequirementsBuilding construction class, Fire protection requirements
Company InfoName, Company Details, the logo with Add logo and Remove
Title PageThe checkbox Print a title page and Location drawing with Add drawing, Replace drawing and Remove

Every field, the logo and the title page are saved in the project file, so you fill them in once per project. Empty fields print nothing; the grey hints are never printed.

Title page

Tick Print a title page to start the PDF with a cover. It is page 1, before the contents, and counts in “Page x of y”; unticked, the report has no such page. The cover has no page header and keeps the footer. From the top it prints your logo, company name and company details, then the report title, “<number>-<name>” and the name of the analysis, then the location drawing, and at the bottom the filled-in project facts: Address, Date, Prepared by, Initials, Checked by and Revision. If the title is empty, the project name is printed in its place.

The location drawing shows where the beam sits in the building. Add drawing imports a PNG, JPG or PDF, for example a plan or a section. Of a PDF, the first page is placed like an image. A PDF that cannot be read shows “The PDF drawing could not be read. It may be encrypted, empty or damaged.” The logo stays PNG or JPG. Click the drawing to place the marker of the open beam, and click again to move it; each analysis has its own marker on the one drawing. The PDF prints the drawing whole inside a thin frame with the marker as a red ring and the analysis name beside it, and the caption “Location of <analysis name>” below. A drawing without a marker for the analysis prints without marker and caption, and without a drawing the cover prints the text only.

Export Document window with the detail level cards
Figure 14.1 · The export view with Standard selected among the four detail levels, the Project Info fields and the footer buttons

Source: spec/beam/report.md rules 4–7 and 62–66; rule 5 for the failure and permission messages.

Detail levels

Choose how much the report prints with the Detail level cards:

Each card shows the real page count for your current result, worked out in the background (“Counting pages…” the first time).

Some content is always printed whatever you choose: the header, the Basis of design and the Summary, and every check whose verdict is not OK, not checked or unsupported. A check that did not pass is printed in its compact form even if you deselect it. The contents and page numbers follow the pages actually printed.

Custom

Custom opens a section tree below the cards. Ticking a parent ticks its children. Locked rows explain themselves: the header, Basis of design and Summary read “Always in the report.”, a check that did not pass reads “Always printed: this check did not pass.” Below the tree you choose:

Save as preset… stores the tree and options under a name in your app settings, so the preset is available in every project. Reset to Standard closes Custom.

Custom report section tree with locked rows
Figure 14.2 · Custom: the section tree, with checks that did not pass locked as Always printed

Source: spec/beam/report.md rules 8–17.

Preview, print and save

Preview opens the PDF view in its own window. Its toolbar has Back to export options, the file name, Page x of y with a page field and arrows, Fit width, Fit page, 100 % with zoom out and zoom in, Print and Export PDF.

  1. While the report is written you see “Generating…”, a progress bar and the section in progress, for example “Section: 5 Utilisation”. The project cannot be edited during this time, so the result cannot change under the report. Cancel stops and writes no file.
  2. When ready, page 1 appears exactly as it prints.
  3. Export PDF opens the system save dialog with “<project name>.pdf” proposed. After saving the view shows “Report exported”, the file name and Open folder; on Android Share takes its place and sends the saved file to the share sheet.
  4. Print sends the same pages to the system print dialog on A4.

If writing fails you see “Export failed” with the reason, for example “The report file could not be written.”, and Retry.

PDF preview showing page 1
Figure 14.3 · The PDF view on page 1: Back to export options, page, zoom, Fit width, Fit page, Print and Export PDF

Source: spec/beam/report.md rules 3, 18–21; spec/beam/phone-and-tablet.md rule 22.

What the pages contain

Pages are A4 and always light. Every page has a header with your logo, company details, “<number>-<name>”, “<date> / <initials>” and the project title, and a footer with the app name and “Page x of y”. Numbered chapters start on a new page, tables and equations are never split, and a continued section repeats its heading with “(continued)”.

ChapterSteelTimber and glulam
SummaryThe overall verdict and one row per check: clause, governing combination, position, utilisation, verdict and reason. One fire row sits outside the governing check.
1 Basis of designDesign code and edition, CEN recommended values or the National Annex, consequence class and KFI, your project requirements, the units, and the axes and sign convention figure
2 Beam geometry and dataBeam summary; 2.1 Materials (fy, fu, γM0, γM1, γM2, and the product stage carbon (A1-A3) table with its total); 2.2 Cross-section with the section figure, properties and plate classification; 2.3 Structural systemBeam summary; 2.1 Materials (strength class, strengths, stiffness, density, design factors with kmod per combination and kdef, and the product stage carbon (A1-A3) table with its total); 2.2 Cross-section; 2.3 Structural system
3 Load cases and combinations3.1 Load cases with the loads figure; 3.2 every relevant combination with its EN 1990 equation and the action factor table
4 Internal forces and reactionsPer relevant combination: a reaction figure that draws the combination's design loads over the characteristic loads as faint dashed outlines, with the legend Design loads · formula at the top left; extremes and support reactions; the M, V and T diagrams for the governing combinations (every combination with Custom › Diagrams: Per combination)
5 Utilisation5.1 Bending, 5.2 Shear, 5.3 Bending and shear, 5.4 Torsion, 5.5 Lateral torsional buckling, 5.6 Fire design5.1 Bending, 5.2 Shear, 5.3 Torsion, 5.4 Lateral torsional buckling, 5.5 Bearing at supports, 5.6 Fire design
6 Performance6.1 Displacements with the project limit and its source; 6.2 Eigenfrequencies with “This criterion is not a full floor vibration check.”
7 AppendixProgram and calculation module versions, calculation date, the input listing and the limitations the engine reports for this beam

The structural system drawing prints every load value next to its arrow. Where loads are too crowded, a position gets a letter badge (A, B, …) and a load table under the drawing lists them. The diagrams and section figures are drawn by the same builders as the app's graphs and cross-section window.

Each check prints its derivation from the same model as the opened check in the app (see Chapter 12): in Full once at its governing combination, followed by a table of the other relevant combinations (combination, position, design value, resistance, utilisation and verdict), in Standard as one compact line with the governing value, resistance, utilisation, clause and verdict.

A combination whose Show in report box is unticked in the Load combinations window (Chapter 5) leaves the combination tables and the per-combination diagrams, unless it governs a check. The calculation still checks it.

Source: spec/beam/report.md rules 7, 22–32, 36–48, 49–53, 56–59; spec/beam/design-code-member-combinations.md rule 44.

Concrete beam reports

A concrete beam prints its own chapter list: Summary; 1 Basis of design (with the National Annex status, γC, γS, αcc, αct and cot θ); 2 Beam geometry and data with 2.1 Materials and cross-section (materials, the section figure and elevation, the bar and stirrup table, durability rows, section properties and the product stage carbon (A1-A3) table with a Concrete and a Reinforcement row) and 2.3 Structural system; 3 Load cases and combinations; 4 Internal forces and reactions; 5 Concrete verification with one block per check, 5.1 Assumptions, warnings and scope and 5.2 Fire design. There is no Performance or Appendix chapter: deflection is one of the check blocks. Each bending block prints a flexure figure with the compression zone, strains and forces.

Source: spec/beam/concrete-report.md rules 1–13.

How values are printed

Symbols are typeset with real subscripts. Section properties print with four significant figures, forces and moments with two decimals, utilisations with three. Every minus is the true minus “−”.

Source: spec/beam/report.md rules 33, 34; spec/beam/concrete-report.md rule 10.

Part IV

How Statiko calculates

Chapter 15

Load combinations

This chapter explains how Statiko builds the load combinations that every analysis and check uses. You never type a combination factor: the app generates all combinations from the project's design code, following EN 1990 and the National Annex you chose. Reading this chapter tells you which combinations exist, which partial and combination factors each one applies, and why a combination appears or does not appear in the list.

Kernel paths in this chapter are under engineering/src/commonMain/kotlin/statiko/engineering/.

How Statiko generates combinations

One project has one National Annex for all its beams. When you choose the country in the Design code dialog, Statiko resolves the partial factors γG and γQ, the reduction applied in expression 6.10b, the consequence factor KFI and the table of combination factors ψ0, ψ1 and ψ2. It then walks a fixed, ordered list of combination definitions and, for each one, computes a single coefficient per action type. Before the static analysis runs, every load of that action type is multiplied by the coefficient.

The countries available are Eurocode (the recommended CEN values), Denmark, Sweden, Serbia and Custom. Eurocode, Serbia and Custom follow the CEN combination policy; Denmark and Sweden each have their own policy. A completed set of coefficients is arithmetic on the factors of the chosen code; it is not a statement that a National Annex has approved the result.

Source: combinations/generateCombinations.kt:10-82; design/DesignCodePresets.kt:22-69; ai/architecture/engineering-rules.md, Combination generation and load application.

What you enter

The deflection and frequency limits stored with each beam are not combination factors; Chapter 21 covers them.

The combination list

Statiko generates the combinations in this order. "Leaders" are wind, snow, live load categories A to H and the Custom load, in that order. A beam with dead load and Custom load alone so gets a 6.10b combination that holds the Custom load, under every country. Under the Serbian annex items 1 to 3 are replaced by STR/GEO - 6.10 once for each leader, then 6.10 with favourable permanent load and wind leading.

  1. STR/GEO - 6.10a, without a leading action.
  2. STR/GEO - 6.10b, once for each leader.
  3. 6.10b with favourable permanent load (G,inf) and wind leading, shown as Leading variable Wind + G.inf.
  4. Characteristic without a leader (permanent load only), then once for each leader, then the G,inf variant with wind leading.
  5. Frequent once for each leader, then the G,inf variant with wind leading.
  6. Quasi-permanent.
  7. Fire - 6.11a/b once for each leader, then the G,inf variant with wind leading.

A combination is offered for your beam only when it is relevant: its leading action is present on the beam, or, for a combination without a leader, a present action has a coefficient other than zero. The quasi-permanent combination is always offered.

Source: combinations/combinationDefinitions.kt:6-20; combinations/combinationRelevance.kt:6-9.

Ultimate limit state: 6.10a, 6.10b and 6.10

EN 1990 6.4.3.2 gives the fundamental combination as the less favourable of two expressions. Statiko computes one coefficient c per action from these rules:

cG = γG · KFIEN 1990 6.4.3.2 (6.10a), (6.10b) · kernel combinations/calculateCombination.kt:96-118
cQ,1 = γQ,1 · KFI (leading action)EN 1990 6.4.3.2 (6.10b) · kernel combinations/calculateCombination.kt:104-120
cQ,i = γQ,i · ψ0,i · KFI (accompanying actions)EN 1990 6.4.3.2 (6.10a), (6.10b) · kernel combinations/calculateCombination.kt:106-120

In these rules γG is γG,sup for 6.10a, the reduced γG,sup for 6.10b, and γG,inf for the G,inf variant, where the permanent load is not multiplied by KFI. Expression 6.10a has no leading action, so every variable action takes ψ0.

Which actions take part depends on the policy. Under the CEN policy 6.10a contains all actions. Under the Danish and Swedish policies 6.10a contains the permanent load only, the option EN 1990 6.4.3.2(3) Note 3 allows. The G,inf variants contain only the permanent load and wind.

Under the Serbian annex Statiko uses EN 1990 Eq. 6.10 alone, as Serbian design practice to SRPS EN 1990/NA:2012 does: each leader gets one 6.10 combination with γG = γG,sup = 1.35 on the permanent load, γQ,1 on the leading action and γQ,i · ψ0,i on the others, all times KFI. There is no 6.10a combination and no reduction factor ξ. The G,inf variant with wind leading stays. The ψ factors, γG,inf, KFI and the SLS and fire combinations are the same as under the Eurocode recommendation. A beam whose selected 6.10a or 6.10b combination the Serbian annex no longer generates moves to the first combination it can show when you apply the design code.

CountryγQ,1 = γQ,iγG,sup in 6.10aγG,sup in 6.10bγG,inf
Eurocode, Custom1.51.351.35 × 0.851.0
Denmark1.51.21.00.9
Sweden1.51.351.35 × 0.891.0
Serbia1.51.35 in 6.10 (no 6.10a or 6.10b)1.0
Consequence classEurocode, Custom (KFI)Denmark (KFI)Sweden (γd)
CC10.90.90.83
CC21.01.00.91
CC31.11.11.0

The CEN values are those of EN 1990 Table A1.2(B). The Danish values follow DS/EN 1990 DK NA Tabel A1.2(B+C), combinations 1 and 2; the Swedish reduction 0.89 and the safety-class factor γd follow EKS 12 Table B-3 and the safety classes SK1 to SK3.

Source: design/actionFactorPresets.kt:9-68; combinations/generateCombinations.kt:104-127; ai/eurocode/en1990_basis_of_design/10_ndp_national_annex_divergence_matrix.md.

Serviceability and fire combinations

The SLS combinations follow EN 1990 6.5.3. No partial factor and no KFI enter them, and the permanent load always takes 1.0.

Characteristic: cQ,1 = 1.0, cQ,i = ψ0,iEN 1990 6.5.3 (6.14b) · kernel combinations/calculateCombination.kt:39-43
Frequent: cQ,1 = ψ1,1, cQ,i = ψ2,iEN 1990 6.5.3 (6.15b) · kernel combinations/calculateCombination.kt:49-53
Quasi-permanent: cQ,i = ψ2,iEN 1990 6.5.3 (6.16b) · kernel combinations/calculateCombination.kt:62

The characteristic combination without a leader contains the permanent load alone. The characteristic G,inf variant takes wind at 1.0 and no other variable action; the frequent G,inf variant takes wind at ψ1 and no live, snow or custom load.

The fire combination follows EN 1990 6.4.3.3:

cQ,1 = ψ1,1, cQ,i = ψ2,i, cG = 1.0EN 1990 6.4.3.3 (6.11b) · kernel combinations/calculateCombination.kt:67-87

The fire G,inf variant contains only the permanent load and wind (combinations/generateCombinations.kt:120-124). In a Swedish fire combination led by live load category C, ψ1 of that action is 0.5, after EKS 12 C chapter 1.1.2 article 12.

Source: combinations/generateCombinations.kt:45-58.

Combination factors ψ

ActionEurocode, Custom ψ0/ψ1/ψ2DenmarkSweden
Live A0.7 / 0.5 / 0.30.5 / 0.3 / 0.20.7 / 0.5 / 0.3
Live B0.7 / 0.5 / 0.30.6 / 0.4 / 0.20.7 / 0.5 / 0.3
Live C0.7 / 0.7 / 0.60.6 / 0.6 / 0.50.7 / 0.7 / 0.6
Live D0.7 / 0.7 / 0.60.6 / 0.6 / 0.50.7 / 0.7 / 0.6
Live E1.0 / 0.9 / 0.80.8 / 0.8 / 0.71.0 / 0.9 / 0.8
Live F0.7 / 0.7 / 0.60.6 / 0.6 / 0.50.7 / 0.7 / 0.6
Live G0.7 / 0.5 / 0.30.6 / 0.4 / 0.20.7 / 0.5 / 0.3
Live H0 / 0 / 00 / 0 / 00 / 0 / 0
Wind0.6 / 0.2 / 00.3 / 0.2 / 0; 0.6 / 0.2 / 0 with category E leading0.3 / 0.2 / 0

Snow depends on the context. Eurocode and Custom: altitude above 1000 m 0.7 / 0.5 / 0.2, below 1000 m 0.5 / 0.2 / 0. Denmark: 0.3 / 0.2 / 0; 0.6 / 0.2 / 0 with category E leading; 0 / 0 / 0 with wind leading. Sweden by characteristic snow load sk: above 3 kN/m² 0.8 / 0.6 / 0.2; 2 to 3 kN/m² 0.7 / 0.4 / 0.2; 1 to 2 kN/m² 0.6 / 0.3 / 0.1. Dead load takes ψ = 1.0. The CEN values are those of EN 1990 Table A1.1.

The Custom load is not a row of this table. It has its own γQ, ψ0, ψ1 and ψ2, one set per project, which you enter or take from a live load category in the Design code dialog (Chapter 5). They start at γQ = 1.5 and ψ = 1.0. The combinations treat it as any variable action with these factors: γQ · KFI leading and γQ · ψ0 · KFI accompanying at ULS, 1.0 and ψ0 in the characteristic, ψ1 and ψ2 in the frequent and fire combinations, and ψ2 in the quasi-permanent combination. Its ψ values are the same whichever action leads, in Denmark too.

Source: design/psiFactorPresets.kt:34-92; design/customLoadFactorPresets.kt; spec/beam/design-code-member-combinations.md rules 23–27.

Custom combinations

A combination you enter on the Custom Combinations tab of the Design code dialog (Chapter 5) is not generated from EN 1990. Each factor you enter is the whole coefficient of its load case: Statiko applies no γ, ψ or KFI on top of it, and the self-weight takes the factor of the permanent load, as in every combination. A load case with no factor, or with the factor 0, is left out.

A user-defined combination is checked together with the generated combinations of its limit state and can govern: ULS in the material checks, SLS characteristic in the instantaneous deflection and, for timber, the final deflection, and Fire in the fire checks. For the timber final deflection Statiko adds the creep of the quasi-permanent loads to your factors: kdef on the permanent load and ψ2 · kdef on every variable load case of the combination, with the ψ2 of the project's design code (EN 1995-1-1 2.2.3(5)). A limit state that has no check for the beam's material gives none.

A beam lists a user-defined combination when the combination holds a factor above 0 for a load case the beam has. It stands after the generated combinations of its limit state in the Load combinations card, the window and the report, under its own name. The report prints its equation as the sum of factor times load case symbol, and its EN 1990 equation cell reads Not relevant.

Source: spec/beam/design-code-member-combinations.md rules 30–34; kernel combinations/applyCombination.kt; verification/TimberFinalCombination.kt.

Applying a combination to the loads

Fd = caction · Fkkernel combinations/applyCombination.kt:6-26

Every point force, axial force, moment and distributed load (both start and end intensity) of an action is multiplied by that action's coefficient; positions, offsets and directions stay as you entered them. The Load combinations window shows each combination's formula row with γ, ψ, KFI and the final coefficient per action.

Characteristic loadsGk deadQk,A live AWk wind6.10b, live A leading× 1.35 · 0.85 · KFI× 1.5 · KFI× 1.5 · 0.6 · KFIDesign loadsGdQd,AWd
Figure 15.1 · One CEN combination: each action's characteristic loads are scaled by one coefficient.

Limits

Chapter 16

Static analysis

This chapter describes how Statiko finds the internal forces, reactions and deflections of your beam. For each load combination the app solves the factored beam with its own finite-element model, then reads every check from that one result. Knowing how the model is built helps you place supports and loads so the result is what you intend, and tells you why a beam is refused as a mechanism.

Kernel paths in this chapter are under engineering/src/jvmAndAndroidMain/kotlin/statiko/engineering/.

The beam model

Eurocode does not prescribe a beam analysis formulation; EN 1990 and EN 1993-1-1 leave the structural analysis method to the designer. Statiko uses its own finite-element method: one-dimensional Euler–Bernoulli beam elements with cubic Hermite shape functions and no shear deformation. Each node has two degrees of freedom, the vertical displacement v and the rotation θ. An internal hinge gives its node a second, independent rotation, so the left and right sides can turn separately.

Within each element, the linearly varying distributed load is added back through the exact particular solution of EI·w'''' = q. The moments, shears and deflections are therefore exact at every point for the load types a beam carries, not only at the nodes. The analysis is linear elastic and first order, and bending is about the strong axis.

Source: fem/dof/BeamBendingDofs.kt:3-9; fem/statics/ExactBeamModel.kt:115-123; fem/statics/ExactBeamElement.kt; ai/architecture/engineering-rules.md, Eurocode first, FEM beyond, practice always.

What feeds the model

Source: calculation/BeamKernelModel.kt:12-53; fem/statics/StaticBeamAnalysisCalculator.kt:29; verification/BeamSectionAnalysisProperties.kt:46-51.

Mesh and stations

Analysis nodes sit at every support, point load, moment load and distributed-load end. Result stations add 250 equal divisions of the member and a neighbour 1 mm either side of every support and load, so peaks and jumps are caught. Positions closer than about 1 mm are merged into one node.

Two placement rules keep loads from vanishing into a free degree of freedom: a point load on a hinge is moved 1 mm to the right, and a moment on a hinge is moved 1 mm to the side you chose. At a node the app reports both the left and the right value, so a jump in the shear force shows in the graph.

Source: fem/element/UnequalElementStrategy.kt:65-96; fem/element/MinimumNodeSpacing.kt:21-34; project/src/commonMain/kotlin/statiko/project/domain/support/BeamNodeSpacing.kt:7-11; ai/architecture/engineering-rules.md, mesh rules 1 and 2.

Element stiffness and loads

The element stiffness matrix for the degrees of freedom (v1, θ1, v2, θ2) of an element of length L is:

k = EI · [ 12/L³, 6/L², −12/L³, 6/L² ; 6/L², 4/L, −6/L², 2/L ; −12/L³, −6/L², 12/L³, −6/L² ; 6/L², 2/L, −6/L², 4/L ]Statiko finite-element method · kernel fem/matrix/BeamBendingMatrices.kt:86-96

A distributed load varying from w1 to w2 over the element gives the equivalent nodal loads:

f = [ L(7w1 + 3w2)/20, L²(3w1 + 2w2)/60, L(3w1 + 7w2)/20, −L²(2w1 + 3w2)/60 ]Statiko finite-element method · kernel fem/statics/ExactBeamElement.kt:11-16

Point forces act on the vertical degree of freedom of their node; a moment acts on the rotation of its side.

Supports, solution and mechanisms

A support that restrains vertical translation fixes v; one that restrains rotation fixes θ. Before solving, Statiko checks the reduced stiffness matrix by Gaussian elimination with scaled partial pivoting and treats it as singular when a pivot is at most 10−10 times its row scale. A singular beam is refused with the message "The beam is a mechanism: its supports and hinges allow free movement"; it is never solved.

The remaining system Kff · uf = Ff is solved with the LAPACK routine dgesv (LU factorisation with partial pivoting).

Source: fem/statics/ExactBeamModel.kt:57-68, 142-148; fem/statics/StiffnessStability.kt:4-26; fem/statics/UnstableBeamException.kt:3-4; linalg/LinAlgImpl.kt:133-171.

Reactions, moments, shears and deflections

R = −(Krow · u − F)Statiko finite-element method · kernel fem/statics/ExactBeamModel.kt:150-166

Within an element the displacement is the Hermite interpolation of the nodal values plus the particular solution vp(s) = (w1s⁴/24 + (w2 − w1)/L · s⁵/120) / EI, corrected so the nodal values are kept. From it:

deflection = −v, rotation = v′, M = −EI · v″, V = −EI · v‴Statiko finite-element method · kernel fem/statics/ExactBeamElement.kt:18-48

Sagging moments are positive. Values smaller than 10−9 are shown as zero. The reactions, the result graphs and every check of the selected combination read this one result (Chapter 11).

Torsion

When the shear centre is offset from the centroid by more than 10−6 m, or a load has an offset, Statiko runs a second finite-element model for torsion. Each node has the twist θ and its gradient θ′ (warping). The element stiffness combines warping and St Venant torsion:

kT = EIw · kHermite + GIt/(30L) · [ 36, 3L, −36, 3L ; 3L, 4L², −3L, −L² ; −36, −3L, 36, −3L ; 3L, −L², −3L, 4L² ]Statiko finite-element method · kernel fem/matrix/TorsionMatrices.kt:13-35; fem/torsion/TorsionMatrixAssembly.kt:59-71
mT = P · (ey − ysc) and mT = w · (ey − ysc)Statiko finite-element method · kernel fem/torsion/TorsionMatrixAssembly.kt:73-107

A support that holds a translation fixes the twist; one that holds a rotation also fixes warping. The torsion constant It, the warping constant Iw and the shear centre come from the finite-element section analysis. The torque, twist and twist gradient at each station feed the steel shear, torsion and warping checks (Chapter 18).

Source: verification/BeamTorsionAnalysis.kt:7-15, 104; fem/data/SupportRestraints.kt:50-55; fem/torsion/TorsionPostProcessor.kt:15-46.

Phinge: θ left, θ rightnodes at supports, loads, hinge; 250 stations and ±1 mm neighbours between
Figure 16.1 · The beam as Statiko models it: nodes at supports and loads, a hinge with two independent rotations.

Limits

Chapter 17

Lateral-torsional buckling

This chapter explains how Statiko checks lateral-torsional buckling, the sideways buckling and twisting of a beam whose compression flange is not held. It describes how the app finds the elastic critical moment Mcr over the whole member, and how Mcr then gives the steel reduction factor χLT and the timber factor kcrit. Use it to understand the values in the LTB check details and what the Top flange laterally restrained box changes.

Kernel paths in this chapter are under engineering/src/jvmAndAndroidMain/kotlin/statiko/engineering/ unless they begin with steel/, timber/ or verification/CriticalMomentResult.kt, which are under engineering/src/commonMain/kotlin/statiko/engineering/.

Critical moment as an eigenvalue

EN 1993-1-1 6.3.2.2(2) requires Mcr to be based on gross section properties and to take into account the loading conditions, the real moment distribution and the lateral restraints. The standard gives no formula for it. Statiko therefore computes Mcr with its own finite-element linear buckling analysis over the whole member. From the static moments, shears and loads of the combination it builds a stiffness matrix K and a geometric stiffness matrix KG, and solves the generalised eigenvalue problem:

K · φ = λ · KG · φStatiko finite-element method · kernel fem/ltb/CriticalBucklingCalculator.kt:39

The smallest positive eigenvalue λcr is the factor by which the combination's loads must grow before the beam buckles. The critical moment is that factor times the largest moment of the static solution:

Mcr = λcr · |Mmax|Statiko finite-element method · kernel verification/BeamCriticalMoment.kt:71

Because the whole member, its real moment diagram, its supports and the height of each load enter the model, no equivalent uniform moment factor or effective length is needed.

What feeds the analysis

Source: calculation/BeamKernelModel.kt:15-41; verification/BeamCriticalMoment.kt:16-32; timber/TimberStabilityStiffnessResolver.kt:12-57.

The buckling model

Each node has four degrees of freedom: lateral displacement u, lateral slope u′, twist φ and warping φ′. The member is meshed with 50 equal divisions plus nodes at the supports and loads. At an internal hinge the right side gets its own lateral slope and warping; a hinged model that can move sideways as a mechanism is refused.

The elastic stiffness combines lateral bending, g · EIz times the Hermite beam matrix, with warping and St Venant torsion, for example:

k33 = 12EIw/L³ + 6GJ/(5L), k34 = 6EIw/L² + GJ/10, k44 = 4EIw/L + 2GJL/15, k48 = 2EIw/L − GJL/30Statiko finite-element method · kernel fem/matrix/LateralTorsionalBucklingMatrices.kt:6-40
g = 1 − (EIyz)² / (EIy · EIz)Statiko finite-element method · kernel fem/ltb/CriticalBucklingMatrixAssembly.kt:37

The geometric stiffness of each element adds the moment M1 and shear V1 at the element start (giving the linear change of moment along it), every point load P with its height term (ez − y0), every applied moment, and every distributed load q with its height (ay − y0). The monosymmetry term is:

ax = [Iy(Ixβx − Ixyβy) − 2Ixy(Iyx0 − Ixyy0)] / (IxIy − Ixy²)Statiko finite-element method · kernel fem/ltb/CriticalBucklingMatrixAssembly.kt:40

Here x0, y0 are the shear centre coordinates and βx, βy the section's monosymmetry constants, in the kernel's section axes.

Source: fem/dof/BeamLtbDofs.kt:3-10; fem/ltb/BeamLtbDofMap.kt:14-21; fem/ltb/LtbHingeStability.kt:9-30; fem/ltb/CriticalBucklingMatrixAssembly.kt:72-123.

Restraints and the eigenvalue solution

Every support that holds a vertical translation is a fork support: it fixes the lateral displacement u and the twist φ. A support that holds a rotation also fixes u′ and φ′. Restrained degrees of freedom are removed from K and KG. Discrete lateral restraints between supports and restraint over part of the length are not available in this version.

  1. K and KG are scaled by si = 1/√Kii.
  2. LAPACK dsygvd solves KG · x = μ · K · x with K as the positive definite matrix; λ = 1/μ.
  3. Modes with |μ| ≤ n · ulp(1) · max|μ| are dropped.
  4. Each λ is refined by the Rayleigh quotient λ = (φTKφ) / (φTKGφ) with compensated summation, and the list is sorted.
  5. λcr is the first positive eigenvalue.

Source: fem/data/SupportRestraints.kt:57-68; linalg/LinAlgImpl.kt:8-71 (computeSymmetricDefiniteEigenvalues); fem/data/LTBData.kt:8. The non-symmetric path keeps only real, finite eigenvalues (linalg/realGeneralizedEigenvalue.kt:5-8).

The result is one of four kinds: computed, not computed (no moment, no positive eigenvalue or an unsupported section), unavailable (the native solver is missing) or failed calculation. Only a computed Mcr can give a result (verification/CriticalMomentResult.kt:3-11).

Steel: χLT and Mb,Rd

Statiko follows the general case of EN 1993-1-1 6.3.2.2.

λ̄LT = √(Wy · fy / Mcr)EN 1993-1-1 6.3.2.2 · kernel steel/SteelMemberVerifier.kt:427
ΦLT = 0.5 · [1 + αLT · (λ̄LT − 0.2) + λ̄LT²]EN 1993-1-1 6.3.2.2 (6.56) · kernel steel/SteelMemberVerifier.kt:428
χLT = 1 / (ΦLT + √(ΦLT² − λ̄LT²)) ≤ 1.0EN 1993-1-1 6.3.2.2 (6.56) · kernel steel/SteelMemberVerifier.kt:429-436
Mb,Rd = χLT · Wy · fy / γM1, utilisation = MEd / Mb,RdEN 1993-1-1 6.3.2.1 (6.54), (6.55) · kernel steel/SteelMemberVerifier.kt:273-275

Wy is the plastic modulus for Class 1 and 2 and the elastic modulus for Class 3. The buckling curve follows Table 6.4, general case:

Sectionh/b ≤ 2h/b > 2
Rolled Ia (αLT = 0.21)b (αLT = 0.34)
Welded Ic (αLT = 0.49)d (αLT = 0.76)
Other sectionsd (αLT = 0.76)

Source: steel/SteelLateralTorsionalCurve.kt:9-20; steel/SteelBucklingCurve.kt:3-9; EN 1993-1-1 Tables 6.3 and 6.4.

When you tick Top flange laterally restrained and no station moment of a combination is negative, that combination is covered: steel LTB is Not evaluated for it, by EN 1993-1-1 6.3.2.1(2), and no Mcr is computed. A combination with hogging anywhere is checked as normal.

When torsion produces a warping demand, Statiko checks LTB only on a simply supported single span, with the member interaction of SCI P385 3.2; on other beams the LTB check is Unsupported. The interaction, with kw = 0.7 − 0.2 · Mw,Ed/Mw,Rd, is:

My,Ed/Mb,Rd + 1.0 · Mz,Ed/Mz,Rd + kw · (1 − Mz,Ed/Mz,Rd) · 1/(1 − My,Ed/Mcr) · Mw,Ed/Mw,RdSCI P385 3.2 · kernel steel/SteelMemberVerifier.kt:109-133

Source: spec/beam/lateral-restraint.md rules 6 to 8; verification/SteelBeamChecks.kt:285-308, 567-568, 683-689.

Timber: kcrit

σm,crit = Mcr / WyEN 1995-1-1 6.3.3 · kernel timber/TimberBeamUtilizationCalculator.kt:164
λrel,m = √(fm,k / σm,crit)EN 1995-1-1 6.3.3 (6.30) · kernel timber/TimberBeamUtilizationCalculator.kt:174
kcrit = 1 for λrel,m ≤ 0.75; 1.56 − 0.75 · λrel,m for 0.75 < λrel,m ≤ 1.4; 1/λrel,m² for λrel,m > 1.4EN 1995-1-1 6.3.3 (6.34) · kernel timber/TimberBeamUtilizationCalculator.kt:175-179
σm,d / (kcrit · fm,d) ≤ 1, fm,d = fm,k · kmod · kh · ksys / γMEN 1995-1-1 6.3.3 (6.33) · kernel timber/TimberBeamUtilizationCalculator.kt:43-44, 181

ksys enters fm,d only, not the slenderness. For a covered combination kcrit = 1.0 by EN 1995-1-1 6.3.3(5); the fork supports provide the torsional restraint that clause also requires. Statiko does not use the effective lengths of Table 6.1: Mcr comes from the eigenvalue problem. Without a computed Mcr the timber LTB check is Unavailable.

What you see

The Lateral torsional buckling check card and its details show Mcr, αLT, λ̄LT, ΦLT, χLT, γM1 and Mb,Rd for steel, or σm,crit, λrel,m, kcrit and fm,d for timber (Chapter 12). The report prints the same derivation in its LTB section (Chapter 14).

shear centreP at height ezu (lateral)φ (twist)
Figure 17.1 · Lateral-torsional buckling: the section moves sideways by u and twists by φ; a load above the shear centre makes it worse.

Chapter 18

Steel checks

This chapter explains how Statiko verifies a steel beam against EN 1993-1-1 for every ultimate limit state combination. It covers the partial factors of each National Annex, the cross-section classification, the resistances in bending, shear and torsion and how they interact, and where the stability check of Chapter 17 fits in. Use it to read the four steel check cards and their details, and to understand why a section is refused rather than passed.

Kernel paths in this chapter are under engineering/src/commonMain/kotlin/statiko/engineering/, except verification/SteelBeamChecks.kt and verification/limitedToBeamAxialScope.kt, which are under engineering/src/jvmAndAndroidMain/kotlin/statiko/engineering/.

How the steel checks run

For every ULS combination Statiko takes the station results of the static analysis (Chapter 16) and checks each station. It first resolves the design yield strength and the partial factors, classifies the section for strong-axis bending, refuses a Class 4 section, and picks the plastic or elastic modulus by class. It then produces four checks: Bending, Shear, Torsion and Lateral torsional buckling. Each check names its governing combination and position.

What feeds the checks: the profile and its manufacturing (rolled or welded), the steel grade and product standard, which give fy by thickness (Chapter 6), the design code with its country and steel robustness setting, the top flange restraint, and the loads with their offsets.

Source: verification/SteelBeamChecks.kt:160-517; ai/architecture/engineering-rules.md, Steel classification and effective-section boundary, Profile feasibility boundary.

Partial factors

National AnnexγM0γM1γM2
Eurocode1.01.01.25
Denmark1.11.21.35
Sweden1.01.01.1
Serbia1.01.01.25
Customthe values you enter in the Design code dialog

The Eurocode values are the recommended values of EN 1993-1-1 6.1. When you switch on steel robustness, every γM is multiplied by 1.2:

γM,used = 1.2 · γM (robustness on)kernel steel/SteelDesignFactorResolver.kt:6-13

Source: design/materialFactorPresets.kt:18-58.

Cross-section classification

ε = √(235 MPa / fy)EN 1993-1-1 Table 5.2 · kernel steel/classification/steelBeamClassificationEpsilon.kt:6-12

fy is the design yield strength for the governing thickness. Each plate of the section is compared with the Table 5.2 limits on c/t:

PartClass 1Class 2Class 3
Internal part, compression33ε38ε42ε
Internal part, bending72ε83ε124ε
Outstand, compression9ε10ε14ε
Tube, d/t50ε²70ε²90ε²
Angle, h/t and (b + h)/2t––15ε and 11.5ε

A ratio above the Class 3 limit is Class 4, and the section takes the class of its least favourable plate. Beam checks classify for strong-axis bending. The class shows in the Member card header.

Source: steel/classification/BucklingElement.kt:12-117; steel/classification/BucklingElementRow.kt:18-24; verification/SteelBeamChecks.kt:181-186, 889.

Bending

Mc,Rd = W · fy / γM0, W = Wpl for Class 1 and 2, W = Wel,min for Class 3EN 1993-1-1 6.2.5 (6.13), (6.14) · kernel steel/SteelMemberVerifier.kt:405-417; steel/SteelResistanceSectionResolver.kt:63-72

The utilisation is |MEd| / Mc,Rd at every station; the highest governs.

When the coexistent shear at a station exceeds half the shear resistance, the moment resistance is reduced by EN 1993-1-1 6.2.8:

ρ = (2 · VEd/VRd − 1)²EN 1993-1-1 6.2.8 · kernel steel/SteelShearBendingReduction.kt:37-38
My,V,Rd = (Wpl,y − ρ · Aw² / (4 tw)) · fy / γM0 ≤ Mc,Rd, Aw = hw · twEN 1993-1-1 6.2.8 (6.30) · kernel steel/SteelShearBendingReduction.kt:39-47

VRd is the shear resistance already reduced for torsion. The reduction is applied for equal-flange I and H sections in Class 1 or 2 without warping demand; for other shapes, Class 3, or a shear ratio above 1, Bending reads Unsupported with the reason shear-bending interaction required.

When torsion creates a warping bimoment, Bending uses the cross-section interactions of SCI P385 3.1:

plastic: (My,Ed/My,Rd)² + Mz,Ed/Mz,Rd + Mw,Ed/Mw,Rd ≤ 1; elastic: My,Ed/My,Rd + Mz,Ed/Mz,Rd + Mw,Ed/Mw,Rd ≤ 1SCI P385 3.1.2 and 3.1.1 · kernel steel/SteelMemberVerifier.kt:97-107

Source: verification/SteelBeamChecks.kt:352-479.

Shear and shear with torsion

Vpl,Rd = Av · (fy / √3) / γM0EN 1993-1-1 6.2.6 (6.18) · kernel steel/SteelShearTorsionResistance.kt:5-8

The shear area Av follows EN 1993-1-1 6.2.6(3):

SectionAv
Rolled I or HA − 2btf + (tw + 2r)tf, not less than η · hw · tw
Welded I or Hη · hw · tw
Rolled channelA − 2btf + (tw + r)tf
Rolled TA − btf + (tw + 2r)tf/2
Welded Ttw · (h − tf/2)
Box with equal flangesη · 2 · hw · tw
Rectangular hollowA · h / (b + h)
Circular hollow2A / π

For zee and solid sections, welded channels and boxes with inclined webs, Statiko uses the shear area from its finite-element section analysis; the check details name this basis. Angles use the elastic shear resistance VRd = (fy/√3)/γM0 · I · t / S (EN 1993-1-1 6.2.6(4), (6.19) and (6.20); steel/SteelShearTorsionResistance.kt:40-51), and with torsion VRd,T = (1 − τt / ((fy/√3)/γM0)) · VRd (6.2.7(5) with 6.2.1(5); steel/SteelShearTorsionResistance.kt:53-62). η = 1.2 for fy ≤ 460 MPa and 1.0 above (EN 1993-1-5 5.1(2) Note 2).

Source: steel/SteelShearArea.kt:12-151; design/SteelShearEtaResolver.kt:20-35.

With torsion, the shear stress τt,Ed reduces the shear resistance by EN 1993-1-1 6.2.7(9). For I and H sections and channels it is the St Venant stress τt,Ed = Tt · t / It, with Tt = G · It · θ′ when a twist gradient exists and the total torque otherwise (steel/SteelShearTorsionCalculator.kt:93-106, :150-158). For hollow sections it is the Bredt stress τt,Ed = |T| / (2 · Am · t), with Am the area enclosed by the wall midline and t the wall thickness (steel/SteelShearTorsionResistance.kt:16-19):

I or H: Vpl,T,Rd = √(1 − τt,Ed / (1.25 · (fy/√3)/γM0)) · Vpl,RdEN 1993-1-1 6.2.7(9) (6.26) · kernel steel/SteelShearTorsionResistance.kt:20-24
Channel: Vpl,T,Rd = [√(1 − τt,Ed / (1.25 · (fy/√3)/γM0)) − τw,Ed / ((fy/√3)/γM0)] · Vpl,RdEN 1993-1-1 6.2.7(9) (6.27) · kernel steel/SteelShearTorsionResistance.kt:26-37
Hollow: Vpl,T,Rd = [1 − τt,Ed / ((fy/√3)/γM0)] · Vpl,RdEN 1993-1-1 6.2.7(9) (6.28) · kernel steel/SteelShearTorsionResistance.kt:63-66

Before the shear check, Statiko tests whether the web is slender enough for shear buckling:

hw / tw > 72 · ε / η ⇒ shear buckling check requiredEN 1993-1-1 6.2.6(6) (6.22) · kernel steel/SteelShearBucklingRelevance.kt:14-41

If it is, Shear reads Unsupported with the reason shear buckling required: the EN 1993-1-5 shear buckling resistance is not available in this version.

Torsion

The torsion check compares the largest torque with a resistance from the section's torsion modulus Wt, which Statiko's finite-element section analysis provides. This resistance form is Statiko's own method; the utilisation follows TEd/TRd ≤ 1 of EN 1993-1-1 6.2.7.

TRd = Wt · (fy / √3) / γM0, utilisation = |TEd| / TRdStatiko method · kernel steel/SteelTorsionCalculator.kt:33-36

Stability

Lateral-torsional buckling follows EN 1993-1-1 6.3.2 with Mcr from the eigenvalue analysis, χLT and Mb,Rd = χLT · Wy · fy / γM1; Chapter 17 gives every step. Flexural buckling under compression is not checked for beams, because the beam carries no axial force.

hbtw, c webtf, c outstandshaded: the web, hw · tw≤ 72ε≤ 83ε≤ 124εClass 4web in bending: Class 1 · 2 · 3 · 4 by c/t
Figure 18.1 · The plate widths c and thicknesses used for classification, and the class bands for a web in bending.

Results and limits

Each card shows the utilisation, status and governing combination and position; the check details show the terms: Wy, class, fy and γM0 for Bending; Av and its basis, Vpl,Rd, VRd and the buckling-relevance terms for Shear; Wt for Torsion (Chapter 12).

Source: verification/SteelBeamChecks.kt:166-233, 501-516; verification/limitedToBeamAxialScope.kt:4-15.

Chapter 19

Timber and glulam checks

This chapter explains how Statiko checks a solid timber or glulam beam at the ultimate limit state. You see where every factor in a timber check comes from (kmod, kh, ksys, γM, kcr, kcrit and kc,90), which inputs drive them, and what each check card means. The basis is EN 1995-1-1:2004 + A1:2008. Serviceability, with the final deflection and kdef, is in Chapter 21, and fire is in Chapter 22.

Kernel paths in this chapter are under engineering/src/commonMain/kotlin/statiko/engineering/ unless they start with verification/, which is under engineering/src/jvmAndAndroidMain/kotlin/statiko/engineering/.

How the checks run

For every ultimate limit state combination (EN 1990 6.10a, 6.10b, 6.10b with Ginf, 6.10 and 6.10 with Ginf under the Serbian annex, and Custom), Statiko takes the bending moment, shear force and torque at every station of the finite-element result (Chapter 16) and the support reactions. It then checks a rectangular section by elementary stresses against design strengths. Five checks run: bending, shear, torsion, lateral-torsional buckling and bearing. Each check keeps its worst station. Across combinations, the governing combination is the one with the largest utilisation.

Only ultimate limit state combinations govern these checks. Serviceability and fire combinations never do. The Unit expression is used only when the beam has no ultimate limit state combination.

Source: ai/architecture/engineering-rules.md, Timber member factor boundary; kernel timber/TimberUlsCombination.kt:5-16, timber/TimberGoverningCombinationSelector.kt:6-25.

What you enter

Source: kernel project/src/commonMain/kotlin/statiko/project/domain/material/TimberGradeType.kt (EN 338:2016, EN 14080:2013); design/materialFactorPresets.kt:24-29; EN 1995-1-1 2.4.1 Table 2.3; spec/beam/supports.md rule 30.

Design strength factors

Load duration and kmod

An action takes part in a combination when its coefficient in that combination is not zero. Every participating action needs exactly one load duration; a missing or duplicated duration makes the timber checks Invalid input. The governing duration is the shortest duration among the participating actions, as EN 1995-1-1 3.1.3(2) requires. kmod then comes from Table 3.1 for solid timber and glulam:

Service classPermanentLong-termMedium-termShort-termInstantaneous
1 and 20.600.700.800.901.10
30.500.550.650.700.90

Source: EN 1995-1-1 3.1.3, Table 3.1; kernel timber/TimberDesignFactorResolver.kt:54-72, :87-103.

Size factor kh

A shallow section gets a higher bending strength. With h the section depth:

solid timber: kh = min[(150 / h)0.2 ; 1.3] for h < 150 mm, otherwise 1.0EN 1995-1-1 3.2(3) (3.1) · kernel timber/TimberRectangularSection.kt:9-13
glulam: kh = min[(600 / h)0.1 ; 1.1] for h < 600 mm, otherwise 1.0EN 1995-1-1 3.3(3) (3.2) · kernel timber/TimberRectangularSection.kt:14-17

Design strengths

fm,d = fm,k · kmod · kh · ksys / γMEN 1995-1-1 2.4.1 (2.14), 3.2, 6.6 · kernel timber/TimberBeamUtilizationCalculator.kt:43-44
fv,d = fv,k · kmod · ksys / γMEN 1995-1-1 2.4.1 (2.14), 6.6 · kernel timber/TimberBeamUtilizationCalculator.kt:45-46

Bending, shear and torsion

Bending

The beam bends about one axis, so the bending check is the uniaxial form of EN 1995-1-1 6.1.6:

σm,d = |MEd| / Wy ; η = σm,d / fm,dEN 1995-1-1 6.1.6 (6.11) · kernel timber/TimberBeamUtilizationCalculator.kt:47, :54

Shear and the crack factor kcr

Shear uses the peak shear stress of a rectangle on the effective width bef = kcr · b, which allows for drying cracks:

τd = 1.5 · |VEd| / (A · kcr) ; η = τd / fv,dEN 1995-1-1 6.1.7 (6.13), (6.13a) · kernel timber/TimberRectangularSection.kt:20-22, timber/TimberBeamUtilizationCalculator.kt:55-75

The design country sets kcr:

Design countrykcr in Statiko
Eurocode0.67
Denmark1.0 (DS/EN 1995-1-1 DK NA:2024 6.1.7(2))
Serbia0.67, the same value as Eurocode
SwedenShear Unavailable: EKS 12 ties kcr to rain and sun exposure, which the input does not hold
CustomYour value, above 0 and at most 1.0; shear Unavailable until you enter it

Source: kernel timber/TimberShearCrackFactorResolver.kt:6-19, timber/TimberShearCrackFactor.kt:8-14.

Statiko includes every load near a support in the shear force. The reduction of EN 1995-1-1 6.1.7(3) is not available in this version.

Torsion

The torsional shear stress is τtor,d = |T| / Wtor, with the torque T of the torsion analysis and Wtor = h · b² / (3 + 1.8 · b/h). This torsion modulus is the kernel's own; EN 1995-1-1 gives none (timber/TimberBeamUtilizationCalculator.kt:49-53). With h the larger and b the smaller side, it is checked against the shear strength raised by the shape factor:

kshape = min(1 + 0.15 · h / b ; 2.0) ; η = τtor,d / (kshape · fv,d)EN 1995-1-1 6.1.8 (6.14), (6.15) · kernel timber/TimberBeamUtilizationCalculator.kt:52-53, :79

Lateral-torsional buckling

When the top flange is laterally restrained, kcrit = 1.0 (EN 1995-1-1 6.3.3(5)) and the check is the bending check. Otherwise Statiko uses the critical moment Mcr of the member, the lowest eigenvalue of the buckling problem in Chapter 17, rather than the effective lengths of Table 6.1.

Mcr needs fifth-percentile stiffnesses. The material carries their basis:

σm,crit = Mcr / Wy ; λrel,m = √(fm,k / σm,crit)EN 1995-1-1 6.3.3 (6.30) · kernel timber/TimberBeamUtilizationCalculator.kt:164-174
kcrit = 1.0 for λrel,m ≤ 0.75 ; 1.56 − 0.75 · λrel,m for 0.75 < λrel,m ≤ 1.4 ; 1 / λrel,m2 for λrel,m > 1.4EN 1995-1-1 6.3.3 (6.34) · kernel timber/TimberBeamUtilizationCalculator.kt:175-179
η = σm,d / (kcrit · fm,d)EN 1995-1-1 6.3.3 (6.33) · kernel timber/TimberBeamUtilizationCalculator.kt:180-181

The slenderness uses the characteristic strength fm,k alone; ksys enters only fm,d.

Source: kernel timber/TimberStabilityStiffnessResolver.kt:11-57, verification/TimberBeamChecks.kt:241-291.

Bearing at the supports

Bearing is compression perpendicular to the grain over each Fixed, Pinned or Roller support. Statiko centres the contact length lb you enter on the support. At each side, the contact length is extended by the smallest of 30 mm, lb, half the clear distance l1 to the next contact, or the distance to the member end (Figure 6.2). The member starts and ends at its first and last support, so at an end support the outer extension is 0 and only the inner side is extended.

lef = lb + eleft + eright ; Aef = lef · bEN 1995-1-1 6.1.5(1), Figure 6.2 · kernel timber/TimberBearingCalculator.kt:57-89
fc,90,d = kmod · fc,90,k / γMEN 1995-1-1 2.4.1 (2.14) · kernel timber/TimberBearingCalculator.kt:46-47
σc,90,d = R / Aef ; η = σc,90,d / (kc,90 · fc,90,d)EN 1995-1-1 6.1.5 (6.3), (6.4) · kernel timber/TimberBearingCalculator.kt:91-95

kh and ksys do not enter the bearing strength. kc,90 is 1.0 unless every clear distance l1 to an adjacent contact is at least 2h (one distance at an end support, two at an internal one) and the material qualifies; a single bearing with no neighbour keeps 1.0 (timber/TimberBearingCalculator.kt:146-156). Then kc,90 is 1.5 for solid softwood, and 1.75 for glulam when lb ≤ 400 mm (6.1.5(4), discrete supports). The governing support is the one with the largest utilisation.

A support without a bearing length makes the check Not checked with "Support B has no bearing length." A support that carries a moment (a fixed end) makes the check Unsupported.

Source: kernel timber/TimberBearingCalculator.kt:141-156, verification/TimberBeamChecks.kt:169-239; spec/beam/supports.md rule 30.

l_b +30 mm +30 mm l_1 (k_c,90 above 1.0 needs l_1 ≥ 2h on both sides) h A_ef = l_ef · b
Figure 19.1 · The effective contact length lef: lb centred on the support, extended up to 30 mm at each side; at an end support only the inner side is extended.

What you see

The timber checks column shows Bending, Shear, Torsion, Lateral-torsional buckling and Bearing, and a timber utilisation summary. Each check shows its utilisation, governing combination and position. Its detail lists the terms: kmod with the service class and governing duration, kh, ksys, γM, the characteristic and design strengths and the stress. Shear adds kcr and bef. Torsion adds kshape. Lateral-torsional buckling adds σm,crit, λrel,m, kcrit and Mcr. Bearing adds lef, Aef, kc,90 and the reaction. The report prints the same result; it never recalculates.

A check that cannot run reads Unavailable with its reason, Not checked, Unsupported, Invalid input or Calculation failed. None of these counts as a pass. A utilisation above 1.0 is a failed check that is still printed in full.

Limits of this version

Chapter 20

Concrete checks

This chapter explains how Statiko verifies a reinforced concrete beam to EN 1992-1-1. It covers the material values, the bending resistance from strain-plane equilibrium, shear, torsion, the detailing rules, and the serviceability checks: stresses, crack width and deflection. Read it to understand what each concrete check card means and which of your inputs change it. Concrete in fire is in Chapter 22.

Kernel paths in this chapter are under engineering/src/commonMain/kotlin/statiko/engineering/ unless they start with verification/, which is under engineering/src/jvmAndAndroidMain/kotlin/statiko/engineering/. The calculation follows EN 1992-1-1:2004 with its 2008 and 2010 corrigenda; the result names the intended edition EN 1992-1-1:2004+A1:2014 (spec/beam/concrete-calculation.md rule 14).

How the verification runs

Statiko runs one verification per beam, in a fixed order. It validates the input and derives the material values from fck. It resolves the National Annex parameters and takes the signed actions per station and combination from the finite-element result (Chapter 16). Then it calculates:

  1. ULS bending resistance, positive and negative, by strain compatibility and force equilibrium;
  2. ULS shear, without and with links;
  3. torsion, where a non-zero torsional moment is proven;
  4. detailing limits;
  5. SLS stresses;
  6. cracking, minimum steel and crack width;
  7. short-term and creep-adjusted deflection.

Stresses and the short-term deflection use the characteristic combinations. The quasi-permanent concrete stress limit, crack width, minimum crack steel and creep-adjusted deflection use the quasi-permanent combinations. Internally every value is SI.

Source: spec/beam/concrete-calculation.md rules 17, 18 and 22.

Materials and partial factors

All strengths are derived once from fck (MPa), EN 1992-1-1 Table 3.1, for classes up to C90/105:

fcm = fck + 8 ; fctm = 0.30 · fck2/3 (fck ≤ 50), 2.12 · ln(1 + fcm / 10) (fck > 50)EN 1992-1-1 3.1.2, Table 3.1 · kernel concrete/ConcreteStrengthProperties.kt:10-20
fctk,0.05 = 0.7 · fctm ; fctk,0.95 = 1.3 · fctm ; Ecm = 22 000 · ((fck + 8) / 10)0.3EN 1992-1-1 Table 3.1 · kernel concrete/ConcreteStrengthProperties.kt:22-25
fcd = αcc · fck / γC ; fctd = αct · fctk,0.05 / γC ; fyd = fyk / γSEN 1992-1-1 3.1.6 (3.15), (3.16) · kernel concrete/ConcreteAnnexFactors.kt:57-87

The design country sets the factors:

Design countryγCγSαcc, αctStatus
Eurocode1.501.151.0Eurocode recommended
Denmark1.451.201.0DS/EN 1992-1-1 DK NA:2024
Serbia1.501.151.0Eurocode recommended; the Serbian National Annex was not checked
Swedennot calculatedUnsupported
Customyour valuesCustom

Source: kernel concrete/ConcreteAnnexFactors.kt:99-157; spec/beam/concrete-calculation.md rules 13 and 15; spec/column/column-calculation.md rule 23.

Bending resistance

Stress-strain laws

Beam bending uses the rectangular stress block of 3.1.7(3), written as a strain law:

εcu3 = 3.5 ‰ (fck ≤ 50), (2.6 + 35 · ((90 − fck) / 100)4) ‰ (fck > 50)EN 1992-1-1 Table 3.1 · kernel concrete/ConcreteUlsMaterialRules.kt:25-29
λ = 0.8 − (fck − 50) / 400 ; η = 1.0 − (fck − 50) / 200 (λ = 0.8, η = 1.0 for fck ≤ 50)EN 1992-1-1 3.1.7(3) (3.19)–(3.22) · kernel concrete/ConcreteUlsMaterialRules.kt:31-41
σc = η · fcd for εc ≥ (1 − λ) · εcu3, otherwise 0EN 1992-1-1 3.1.7(3) · kernel concrete/Ec2RectangularStressBlockConcreteModel.kt:18-27

When the compression zone narrows towards the extreme fibre, for example in a T beam bending the other way, η is multiplied by 0.9 and the section is solved again (3.1.7(3)). The reinforcement is elastic-perfectly plastic, σs = Es · ε limited to ±fyd, with the design ultimate strain εud = 0.9 · εuk.

Source: kernel concrete/ConcreteFlexureUlsCalculator.kt:13-26, concrete/ElasticPerfectlyPlasticReinforcementModel.kt:16-20, concrete/ConcreteUlsMaterialRules.kt:22-23.

Strain-plane equilibrium

The extreme compression fibre is held at εcu, and the strain varies linearly with the distance dc from the compression face:

ε(z) = εcu · (1 − dc(z) / x)EN 1992-1-1 6.1(2) · kernel concrete/ConcreteBendingSolver.kt:82-89
N(x) = ∫ σc(ε(z)) · b(z) dz + Σ σs(εi) · As,i = 0EN 1992-1-1 6.1 · kernel concrete/ConcreteBendingSolver.kt:54-80

The neutral-axis depth x is the root of N(x) = 0 between a small fraction of h and h, found by bisection (up to 256 iterations, stopping on a position or force tolerance). The concrete integral uses adaptive Simpson integration over the section's real outline. MRd is the first moment of the concrete and bar forces at that root, and the utilisation is |MEd| / MRd for the governing positive or negative moment. If the root is not found, the check reads Calculation failed, never a pass.

Source: kernel concrete/BoundedRootSolver.kt:6-45, concrete/AdaptiveSimpsonIntegrator.kt, concrete/ConcreteBendingSolver.kt:22-46, concrete/ConcreteFlexureUlsCalculator.kt:27-30.

neutral axis ε_cu ε_s x η·f_cd over λx F_s z
Figure 20.1 · Strain plane and stress block: x is found from force equilibrium, and MRd follows from the forces and the lever arm z.

Shear and torsion

Without links

k = min(2.0 ; 1 + √(200 / d)) ; ρl = min(0.02 ; Asl / (bw · d))EN 1992-1-1 6.2.2(1) · kernel concrete/ConcreteShearUlsCalculator.kt:54-55
VRd,c = max[CRd,c · k · (100 · ρl · fck)1/3 ; vmin] · bw · d ; vmin = c · k1.5 · fck0.5EN 1992-1-1 6.2.2 (6.2a), (6.2b) · kernel concrete/ConcreteShearUlsCalculator.kt:56-61

Statiko uses CRd,c = 0.18 / γC and c = 0.035 for every design country except Denmark, which uses c = 0.051 / γC (DS/EN 1992-1-1 DK NA:2024 6.2.2(1)). Units are MPa and mm. The beam has no axial force, so there is no k1 · σcp term.

Source: kernel concrete/ConcreteShearDesignParameters.kt:13-31.

With vertical links

z = 0.9 · d ; VRd,s = (Asw / s) · z · fywd · cot θEN 1992-1-1 6.2.3 (6.8) · kernel concrete/ConcreteShearUlsCalculator.kt:68-71
VRd,max = αcw · bw · z · ν1 · fcd / (cot θ + tan θ) ; ν1 = 0.6 · (1 − fck / 250) ; αcw = 1.0EN 1992-1-1 6.2.3 (6.9), 6.2.2(6) (6.6N) · kernel concrete/ConcreteShearUlsCalculator.kt:73-77

The shear resistance is min(VRd,s ; VRd,max). You choose cot θ between 1.0 and 2.5. The beam shear check uses ν1 = 0.6 · (1 − fck / 250) for every design country, including Denmark. Only vertical links are supported.

Solid circular sections follow Orr et al. (2010), a published extension outside EN 1992-1-1. The lever arm z comes from the section's own bending solution, z = MRd / Ftd.

Source: kernel concrete/ConcreteShearUlsCalculator.kt:22-24, :142-349; spec/beam/concrete-calculation.md rule 17.

Torsion

Torsion is checked only where the analysis proves a non-zero torsional moment. It uses a thin-walled closed cell (the closed web cell for a T beam) with tef = max(A / u ; 2 · axis distance of the longitudinal bars):

TRd,links = 2 · Ak · (Asw / s) · fyd · cot θ ; TRd,long = 2 · Ak · ΣAsl · fyd / (uk · cot θ)EN 1992-1-1 6.3.2(3) (6.28) · kernel concrete/torsion/ConcreteTorsionCalculator.kt:141-143
TRd,max = 2 · Ak · tef · ν · fcd / (cot θ + tan θ)EN 1992-1-1 6.3.2(4) (6.30) · kernel concrete/torsion/ConcreteTorsionCalculator.kt:144-145

Here ν is 0.6 · (1 − fck / 250), or 0.7 · (0.7 − fck / 200) for Denmark. The interactions are T / TRd,max + V / VRd,max ≤ 1 (6.29). For the links, V / VRd,s + T / TRd,links ≤ 1 (6.3.2(2)). For the longitudinal bars, the bending utilisation plus T / TRd,long must not exceed 1. Detailing follows 9.2.3: link spacing at most min(u / 8 ; least dimension), and longitudinal bar spacing at most 350 mm.

Source: kernel concrete/torsion/ConcreteTorsionGeometryCalculator.kt:123-125, concrete/ConcreteStrutStrengthReduction.kt:3-24, concrete/torsion/ConcreteTorsionCalculator.kt:147-182.

Detailing and cover

As,min = max(0.26 · fctm / fyk · bt · d ; 0.0013 · bt · d) ; As,max = 0.04 · AcEN 1992-1-1 9.2.1.1 (9.1N), 9.2.1.1(3) · kernel concrete/ConcreteBeamDetailingRules.kt:21-35
ρw,min = 0.08 · √fck / fyk ; sl,max = 0.75 · dEN 1992-1-1 9.2.2 (9.5N), (9.6N) · kernel concrete/ConcreteBeamDetailingRules.kt:37-45
clear spacing ≥ max(φ ; 20 mm ; dg + 5 mm)EN 1992-1-1 8.2(2) · kernel concrete/ConcreteBeamDetailingRules.kt:47-58
cmin = max(cmin,b ; cmin,dur ; 10 mm) ; cmin,b = φ, or φ + 5 mm when dg > 32 mm ; cnom = cmin + ΔcdevEN 1992-1-1 4.4.1.2 (4.2), Table 4.2 · kernel concrete/ConcreteBeamDetailingRules.kt:60-72

The cover you enter is the nominal cover cnom, measured to the outermost bar, normally the link. cmin,dur comes from Table 4.4N for structural class S4 and reinforcing steel; Denmark uses the DK NA values X0 10, XC1 10, XC2 to XC4 20, XD1 30, XD2 40, XD3 40, XS1 30, XS2 30 and XS3 40 mm (concrete/ConcreteExposureDurabilityResolver.kt:37-50). Δcdev is 10 mm (Eurocode) or 5 mm (Denmark):

ExposureX0XC1XC2, XC3XC4XD1, XS1XD2, XS2XD3, XS3
cmin,dur (mm), Eurocode10152530354045

Source: kernel concrete/ConcreteExposureDurabilityResolver.kt:18-51; spec/beam/concrete-calculation.md rule 20.

Stresses, cracks and deflection

Stress limits

σc ≤ 0.6 · fck and σs ≤ 0.8 · fyk under characteristic combinations. Under quasi-permanent combinations, σc ≤ 0.45 · fck, the limit for linear creep (7.2(2), (3), (5)).

Source: kernel concrete/ConcreteSlsDesignParameters.kt:17-24, concrete/ConcreteBeamSlsVerifier.kt:196-215.

Creep and effective modulus

The creep coefficient φ(t, t0) follows EN 1992-1-1 Annex B. The inputs are the notional size h0 = 2Ac / u, the relative humidity, the temperature-adjusted loading age (corrected for cement class and not less than 0.5 days), and the factors β(fcm) = 16.8 / √fcm, β(t0) = 1 / (0.1 + t00.2), φRH, βH and βc. The long-term modulus is:

Ec,eff = Ecm / (1 + φ(t, t0))EN 1992-1-1 7.4.3(5) (7.20), Annex B · kernel concrete/ConcreteCreepCalculator.kt:11-51, concrete/ConcreteBeamSlsVerifier.kt:17-19

Cracked stiffness and deflection

ζ = 1 − β · (Mcr / M)2 for M > Mcr, otherwise 0 ; Ieff = 1 / [ζ / III + (1 − ζ) / II]EN 1992-1-1 7.4.3 (7.18), (7.19) · kernel concrete/ConcreteBeamSlsVerifier.kt:146-166

Mcr = fctm · II / (distance from the centroid to the tension fibre). β is 1.0 for the short term (characteristic) and 0.5 for the long term (quasi-permanent). Statiko takes one ζ per combination and bending direction, from that combination's largest moment. It then rescales the linear-elastic deflection of the finite-element analysis:

δ = |δFEM| · (E · I)ref / (Ec · Ieff) ; limit = span / ratiokernel concrete/ConcreteBeamSlsVerifier.kt:377-402, verification/ConcreteBeamChecks.kt:113-127

Ec is Ecm for the short-term deflection and Ec,eff for the long-term deflection. Curvatures are not integrated along the member, span-to-depth ratios (7.4.2) are not used, and shrinkage curvature is not available in this version.

Crack width and minimum steel

hc,ef = min[2.5 · (h − d) ; (h − x) / 3 ; h / 2] ; ρp,eff = As / Ac,eff ; φeq = Σφ2 / ΣφEN 1992-1-1 7.3.2(3), 7.3.4 (7.12) · kernel concrete/ConcreteBeamSlsVerifier.kt:276-290
sr,max = 3.4 · c + 0.8 · 0.5 · 0.425 · φ / ρp,eff, or 1.3 · (h − x) when the bar spacing exceeds 5 · (c + φ / 2)EN 1992-1-1 7.3.4(3) (7.11), (7.14) · kernel concrete/ConcreteBeamSlsVerifier.kt:291-297
εsm − εcm = max{[σs − 0.4 · fctm / ρp,eff · (1 + αe · ρp,eff)] / Es ; 0.6 · σs / Es} ; wk = sr,max · (εsm − εcm)EN 1992-1-1 7.3.4 (7.8), (7.9) · kernel concrete/ConcreteBeamSlsVerifier.kt:298-311

σs is the stress in the tension bars of the long-term cracked section under the quasi-permanent moment, using Es / Ec,eff. αe = Es / Ecm. The check passes when wk ≤ your limit wmax and the tension steel is at least:

As,min = (0.4 · k · Act,web + kc,fl · kfl · Act,fl) · fctm / fyk ; kc,fl = max(0.9 · Fcr / (Act · fct,eff) ; 0.5)EN 1992-1-1 7.3.2(2) (7.1), (7.2), (7.3) · kernel concrete/minimumCrackReinforcement.kt:6-41

k is 1.0 up to 300 mm and 0.65 from 800 mm, interpolated in between, for the web depth and the flange width. The minimum is checked even when the section is uncracked (7.3.2(1)).

What you see and the limits

The concrete checks show bending in both directions (x, MRd, bar strains and failure mode), shear (VRd,c or VRd,s and VRd,max with cot θ), torsion, detailing, SLS stresses, crack width, and short-term and long-term deflection with the stiffness assumption named. Each check carries its clause, governing combination and position, intermediate values and state. The report prints the same result.

Source: spec/beam/concrete-calculation.md rules 16, 17 and 23.

Chapter 21

Serviceability

This chapter explains the serviceability checks Statiko runs for steel and timber beams: the instantaneous deflection, the final deflection of timber with creep, and the natural frequency. You learn which combinations feed each check, how the limits you set are applied, and how the frequency is found as the lowest eigenvalue of K·φ = ω²·M·φ. Concrete deflection and crack width have their own method, described in Chapter 20.

Kernel paths in this chapter are under engineering/src/jvmAndAndroidMain/kotlin/statiko/engineering/; paths starting with verification/BeamServiceability, verification/BeamDeflection, verification/TimberFinal or design/ are under engineering/src/commonMain/kotlin/statiko/engineering/.

The limits you set

Each beam stores its own serviceability limits. There are four deflection ratios: span instantaneous, cantilever instantaneous, span final and cantilever final. There is also a frequency limit in hertz. The Design code card shows them read-only in its Deflection row as L/<span> · L/<cantilever> · <f> Hz, and you change them through the card's Edit. A new beam starts with the app's preset, L/400 · L/200 · 8 Hz, for both the instantaneous and the final ratios.

Source: spec/beam/design-code-member-combinations.md rules 5 and 21; kernel design/DesignCodePresets.kt:18-20, :45-50; project/src/commonMain/kotlin/statiko/project/domain/design/DeflectionLimitsInput.kt:3-8.

Instantaneous deflection

Every characteristic combination (EN 1990 6.14b, and its variant with Ginf when wind leads) gives one deflection row. The deflection δ(x) at every station comes from the linear-elastic finite-element solution of that combination with the mean modulus (Chapter 16). It includes everything in the combination, permanent and variable. For each span between supports, and for each cantilever, Statiko takes the largest absolute deflection in that span:

δmax = max |δ(x)| over the span ; wlim = Lspan / ratio ; η = δmax / wlimEN 1990 6.5.3 (6.14b) · kernel verification/BeamServiceabilityChecks.kt:46-70

A span uses the span instantaneous ratio, and a cantilever uses the cantilever instantaneous ratio. The check passes when δmax ≤ wlim + 0.000001 m, a tolerance of one micrometre for rounding. The governing span over all characteristic combinations is shown with its combination and position.

Frequent and quasi-permanent combinations do not give a deflection row. Precamber is not available in this version, so the deflection is never reduced by a precamber.

Source: kernel verification/BeamServiceabilityChecks.kt:79-83, :107; verification/BeamVerificationCalculator.kt:74-91, :180-184.

Final deflection of timber

Timber creeps under sustained load. For a timber or glulam beam, Statiko rebuilds every characteristic combination with creep coefficients from the deformation factor kdef, then solves it again with the mean stiffness. Steel beams have no final deflection row.

Service class123
kdef, solid timber and glulam0.600.802.00

Source: EN 1995-1-1 3.1.4, Table 3.2; kernel verification/TimberFinalCombination.kt:20-25.

cG,fin = 1 + kdef ; cQ,fin = cQ,char + ψ2 · kdefEN 1995-1-1 2.2.3(5) (2.2)–(2.5) · kernel verification/TimberFinalCombination.kt:30-38

cQ,char is the action's coefficient in the characteristic combination: 1.0 for the leading action and ψ0 for an accompanying one. An action left out of the combination stays at 0. This is ufin = uinst + ucreep, with the creep part equal to kdef · uinst for permanent actions and ψ2 · kdef · uinst for variable ones. It assumes that all parts of the beam creep equally and the behaviour stays linear, as 2.2.3(5) states.

The final deflection is then checked like the instantaneous one, with the span final ratio or the cantilever final ratio. The check detail shows kdef. An invalid service class makes the final deflection Unavailable.

Source: kernel verification/BeamServiceabilityChecks.kt:47-52, verification/BeamDeflectionCriterion.kt:16-19, verification/BeamVerificationCalculator.kt:252-292.

Natural frequency: the model

The frequency check uses the same beam line, meshed by default with 50 nodes, refined at supports and loads. Each node has a vertical displacement and a rotation.

mpoint = Σ|Pi| / g ; muniform = Σ|w| / g · Lekernel fem/element/FemElement.kt:19-20, fem/vibration/VibrationMatrixAssembly.kt:56-76, core/Config.kt:4

The element routine also has a consistent mass matrix, m·L / 420 times the standard 4 × 4 Hermite matrix. Statiko gives it no mass per length, so all the mass is the load-derived mass above.

Source: kernel fem/vibration/VibrationCalculator.kt:18-37, fem/matrix/BeamBendingMatrices.kt:15-25, calculation/StaticBeamCalculationService.kt:264-273, :340-351, calculation/BeamKernelModel.kt:21-51.

Natural frequency: the eigenvalue problem

K · φ = ω2 · M · φ ; f = ω / (2π) = √λ / (2π)kernel fem/vibration/VibrationCalculator.kt:40-47, linalg/LinAlgImpl.kt:8-70

The problem is symmetric-definite and is solved with LAPACK dsygvd through OpenBLAS:

  1. Both matrices are scaled by si = 1 / √Kii. K must be positive definite, and both matrices must be exactly symmetric.
  2. Because M has no mass on the rotations, it is singular. dsygvd therefore solves the swapped problem M̃ · x = μ · K̃ · x, where μ = 1 / λ.
  3. Modes with μ ≈ 0, the massless rotational modes, are dropped. Each remaining λ = 1 / μ is refined by the Rayleigh quotient λ = φTKφ / φTMφ, using compensated summation.
  4. Eigenvalues not above 10−9 are dropped, the rest are sorted ascending, and fi = √λi / 2π.

The mode shapes are normalised and drawn on the result graphs (Chapter 11).

φ₁ f₁ = ω₁ / 2π ≥ f_lim mass = load / g at the nodes
Figure 21.1 · The first mode shape φ1 of a two-span beam, with the load-derived masses at the nodes.

Natural frequency: the check

Statiko analyses the beam once for every serviceability combination (characteristic, frequent and quasi-permanent), each with its own load-derived mass, and takes that combination's lowest frequency. The smallest of these over all combinations is checked, and its combination is named. When the beam has no serviceability combination, the unfactored loads are used.

η = flim / f1 ; Passed when η ≤ 1.0, i.e. f1 ≥ flimkernel verification/BeamServiceabilityChecks.kt:92-105, calculation/StaticBeamCalculationService.kt:294-306

If the native linear-algebra library is missing, the check reads Unavailable. A numerical failure reads Calculation failed, never a pass.

What you see and the limits

The Displacements group of the checks column shows Deflection (instantaneous), for timber also Deflection (final) with kdef, and Frequency. Each deflection check lists δmax, wlim, the ratio, the span and the governing combination; the span deflections are listed per span. The frequency check lists f1 and flim. The report prints the same values.

Chapter 22

Fire resistance

This chapter explains how Statiko verifies the fire resistance of a beam once you have entered its fire design (Chapter 13). Steel follows EN 1993-1-2, with heating under the standard fire and two verification methods. Timber and glulam follow EN 1995-1-2 with the reduced cross-section method. Concrete follows the tabulated data of EN 1992-1-2. Fire is the accidental design situation: it never governs the normal checks, the governing summary or the report's governing check.

Kernel paths in this chapter are under engineering/src/jvmAndAndroidMain/kotlin/statiko/engineering/, except combinations/, which is under engineering/src/commonMain/kotlin/statiko/engineering/. Rules are from spec/beam/fire.md.

Fire actions and combinations

The design effects in fire come from the generated fire combinations, one for each leading variable action, plus a variant with Ginf when wind leads. Each fire combination is verified with its own moments and shears, and the result shows the governing one with its combination identity. You never type Efi,d, and Statiko does not use the ηfi shortcut.

Ed,fi = Σ Gk,j + ψ1,1 · Qk,1 + Σi>1 ψ2,i · Qk,iEN 1990 6.4.3.3 (6.11b) · kernel combinations/calculateCombination.kt:68-86

Statiko applies ψ1 to the leading variable action and ψ2 to every other variable action, for every design country. The variant with Ginf contains only the permanent load and wind. A beam with fire input but no fire combination reads Unavailable with its reason.

Source: spec/beam/fire.md rules 15 to 19.

Steel: heating in the standard fire

Standard fire curve

θg = 20 + 345 · log10(8 · t + 1), t in minutesEN 1991-1-2 3.2.1 (3.4) · kernel eurocode/fire/Iso834StandardFireCurve.kt:5-7

Section factor and shadow effect

Am/V is the perimeter of the exposed faces divided by the steel area; [Am/V]b uses the box perimeter. An unprotected member heats with max(Am/V ; 10 m−1) (4.2.5.1(5)). A contour-protected member uses Ap/V = Am/V, and a box-protected member uses [Am/V]b.

ksh = 0.9 · [Am/V]b / [Am/V] (I and H sections) ; [Am/V]b / [Am/V] (other open sections) ; 1.0 (hollow sections and protected members)EN 1993-1-2 4.2.5.1(2) (4.26a), (4.26b) · kernel eurocode/fire/steel/SteelFireShadowFactor.kt:7-21, eurocode/fire/steel/SteelFireSectionFactor.kt:20-49

ksh uses the section's real Am/V, not the floored value.

Thermal properties

ca = 425 + 0.773 · θ − 1.69·10−3 · θ2 + 2.22·10−6 · θ3 (20–600 °C) ; 666 + 13 002 / (738 − θ) (600–735 °C) ; 545 + 17 820 / (θ − 731) (735–900 °C) ; 650 (900–1200 °C) J/kgKEN 1993-1-2 3.4.1.2 (3.2a)–(3.2d) · kernel eurocode/fire/steel/SteelFireSpecificHeat.kt:10-20

ρa = 7850 kg/m³ (3.2.2(1)), and the initial steel temperature is 20 °C unless you change it. With Custom ca and ρa your constant values are used instead.

Unprotected members

ḣnet = αc · (θg − θa) + Φ · εres · σ · [(θg + 273)4 − (θa + 273)4] ; αc = 25 W/m²K, Φ = 1.0, εres = 0.7, σ = 5.67·10−8 W/m²K⁴EN 1991-1-2 3.1 (3.1)–(3.3) · kernel eurocode/fire/steel/SteelFireUnprotectedHeatingStep.kt:6-36
Δθa,t = ksh · (Am/V) / (ca · ρa) · ḣnet · Δt, Δt = 5 sEN 1993-1-2 4.2.5.1 (4.25) · kernel eurocode/fire/steel/SteelFireUnprotectedHeatingStep.kt:36, eurocode/fire/steel/SteelFireStandardFireHeating.kt:58-95

Protected members

φ = (cp · ρp) / (ca · ρa) · dp · Ap/VEN 1993-1-2 4.2.5.2 · kernel eurocode/fire/steel/SteelFireProtectedHeatingStep.kt:41-42
Δθa,t = (λp / dp) · (Ap/V) / (ca · ρa) · (θg − θa) / (1 + φ/3) · Δt − (eφ/10 − 1) · Δθg, not below 0, Δt = 30 sEN 1993-1-2 4.2.5.2 (4.27) · kernel eurocode/fire/steel/SteelFireProtectedHeatingStep.kt:43-47

Each time step takes θg at the end of the step and ca at the current steel temperature. Intumescent coatings are outside Eq. (4.27) and read Unavailable.

Steel: verification

Reduction factors

ky,θ and kE,θ are interpolated linearly in Table 3.1 (3.2.1(1)):

θa (°C)20–100200300400500600700800900100011001200
ky,θ1.0001.0001.0001.0000.7800.4700.2300.1100.0600.0400.0200
kE,θ1.0000.9000.8000.7000.6000.3100.1300.0900.06750.04500.02250

A zero factor means the section has no resistance, and the check reads Failed.

Source: kernel eurocode/fire/steel/SteelFireYieldReductionFactor.kt:7-19, eurocode/fire/steel/SteelFireElasticModulusReductionFactor.kt:7-19, eurocode/fire/steel/SteelFireReductionTable.kt:4-11.

Critical temperature method

γM,fi = 1.0. Its provenance is "CEN recommended" for Eurocode, "DK NA:2007" for Denmark, and "CEN value · national annex not verified" for Sweden and Serbia. A Custom design country leaves steel fire Unavailable.

μ0 = Efi,d / Rfi,d,0 ; μ0,mod = μ0 · κ1 · κ2, not less than 0.013EN 1993-1-2 4.2.4(2), (3) (4.23) · kernel eurocode/fire/steel/SteelFireDegreeOfUtilisation.kt:5-16, eurocode/fire/steel/SteelFireModifiedUtilisation.kt:21, eurocode/fire/steel/SteelFireCriticalTemperature.kt:7-13
θa,cr = 39.19 · ln[1 / (0.9674 · μ03.833) − 1] + 482 ; 350 °C for Class 4EN 1993-1-2 4.2.4 (4.22), 4.2.3.6 · kernel eurocode/fire/steel/SteelFireCriticalTemperature.kt:10-23

Rfi,d,0 is the section's resistance in fire at time zero, capped at MRd. κ1 is 0.70 (unprotected) or 0.85 (protected) when a slab covers the top flange and the top face is not exposed, otherwise 1.0. κ2 is 0.85 only at stations over an intermediate support or a fixed end of a statically indeterminate beam with the box ticked, otherwise 1.0. The method passes when θa at the required time is at most θa,cr. Where the beam's restraint does not hold the compressed flange, this method reads Unavailable, because it cannot rule out instability.

Source: kernel eurocode/fire/steel/SteelFireAdaptationFactors.kt:7-23, eurocode/fire/steel/SteelFireMechanicalPartialFactor.kt:5-31, steel/SteelFireBeamResistance.kt:58-74; spec/beam/fire.md rules 21, 25, 27, 28 and 34.

Resistance method

Vfi,t,Rd = ky,θ · Vpl,Rd (with γM,fi) ; Mfi,θ,Rd = ky,θ · W · fy / γM,fi ; Mfi,t,Rd = min(Mfi,θ,Rd ; MRd) / (κ1 · κ2)EN 1993-1-2 4.2.3.3 (4.8), (4.10), (4.16); 4.2.3.4 (4.17), (4.18), (4.20) · kernel steel/SteelFireBeamResistance.kt:106-170

W is plastic for Class 1 and 2 and elastic for Class 3, and the bending resistance is reduced for high shear as in EN 1993-1-1 6.2.8. For lateral-torsional buckling in fire:

λ̄LT = √(W · fy / Mcr) ; λ̄LT,θ = λ̄LT · √(ky,θ / kE,θ) ; α = 0.65 · √(235 / fy)EN 1993-1-2 4.2.3.3(5) (4.12), (4.13) · kernel eurocode/fire/steel/SteelFireBucklingCurve.kt:8-23, steel/SteelFireBeamResistance.kt:214-244
φ = 0.5 · (1 + α · λ̄LT,θ + λ̄LT,θ2) ; χLT,fi = 1 / (φ + √(φ2 − λ̄LT,θ2)) ; Mb,fi,t,Rd = χLT,fi · ky,θ · W · fy / γM,fiEN 1993-1-2 4.2.3.3(4) (4.11), (4.14), (4.15); 4.2.3.4(3) (4.19) · kernel eurocode/fire/steel/SteelFireBucklingCurve.kt:16-17, steel/SteelFireBeamResistance.kt:238-244

Mcr is the ambient critical moment of Chapter 17, and the compression flange is taken at the uniform steel temperature. The steel fire verdict is the worse of the two methods. When the critical temperature method is Unavailable for instability, the resistance method gives the verdict.

Torsion in fire

EN 1993-1-2 gives no torsion rule. When the fire combination has torsion, for example from an eccentric load, Statiko verifies it with the normal-temperature rules of Chapter 18 at the steel temperature, as a reading of EN 1993-1-2 4.2.1(2), and the report says so beside the check. The critical temperature method then reads Unavailable and the resistance method gives the verdict, because the critical temperature formula presumes a resistance proportional to ky,θ.

τfi,Rd = ky,θ · fy / (√3 · γM,fi) ; Tfi,t,Rd = Wt · τfi,Rd ; Mz,fi,Ed = (φ / kE,θ) · My,fi,Ed ; kα = 1 / (1 − My,fi,Ed / (kE,θ · Mcr))EN 1993-1-2 4.2.1(2) with EN 1993-1-1 6.2.7 (6.23), (6.25) to (6.28) and SCI P385 3.1, 3.2 · kernel steel/SteelFireBeamTorsionResistance.kt

The torques and the warping moment Mw,Ed are those of the analysis, because E and G drop together; the twist φ grows by 1 / kE,θ and Mcr drops by kE,θ. Shear with torsion uses τfi,Rd as its limit. In the warping interactions My takes Mfi,t,Rd and Mb,fi,t,Rd, while Mz,Rd and the flange resistance Mw,Rd take ky,θ · fy / γM,fi without κ1 and κ2. As at normal temperature, a coexistent shear above half its resistance leaves bending Not supported, and lateral-torsional buckling with torsion is covered for a single span on two pinned or roller supports only.

Timber and glulam: reduced cross-section

β0 = 0.65 mm/min ; βn = 0.80 mm/min (solid softwood), 0.70 mm/min (softwood glulam)EN 1995-1-2 3.4, Table 3.1 · kernel eurocode/fire/timber/TimberFireCharringRates.kt:4-17
dchar,n = βn · t ; k0 = t / 20 for t < 20 min, 1.0 from 20 min ; def = dchar,n + k0 · d0, d0 = 7 mmEN 1995-1-2 3.4 (3.2), 4.2.2 (4.1), Table 4.1 · kernel eurocode/fire/timber/TimberFireZeroStrengthLayer.kt:4-12, eurocode/fire/timber/TimberFireEffectiveCharringDepth.kt:5-19

Under gypsum plasterboard type A, charring starts at tch = 2.8 · hp − 14 (EN 1995-1-2 (3.11)). From tch to ta = min(2 · tch ; tch + 25 / (2 · βn)) the charring rate is 2 · βn. After ta, dchar = 25 + βn · (t − ta). Under plasterboard k0 = 1.0 throughout, so before tch def = 7 mm with no charring (eurocode/fire/timber/TimberFireEffectiveCharringDepth.kt:58-66). The kernel cites JRC EUR 26698 6.1 for this part.

Source: kernel eurocode/fire/timber/TimberFireCladdingStartTime.kt:4-9, eurocode/fire/timber/TimberFireEffectiveCharringDepth.kt:34-67.

The residual section loses def from each exposed face. Each exposed left or right face reduces the width, and each exposed top or bottom face reduces the depth. A section consumed by charring, or timber with a density below 290 kg/m³, reads Unavailable.

bfi = b − nleft,right · def ; hfi = h − ntop,bottom · defEN 1995-1-2 4.2.2 · kernel eurocode/fire/timber/TimberFireEffectiveSection.kt:23-26
fd,fi = kmod,fi · kfi · fk / γM,fi ; kmod,fi = 1.0 ; kfi = 1.25 (solid), 1.15 (glulam) ; γM,fi = 1.0EN 1995-1-2 2.3 (2.1), Table 2.1, 4.2.2(5) · kernel eurocode/fire/timber/TimberFireDesignStrength.kt:4-17, eurocode/fire/timber/TimberFireFractileFactor.kt:4-11, eurocode/fire/timber/TimberFireMechanicalPartialFactor.kt:5-14
σm,d = M / Wfi ; τd = 1.5 · V / Afi ; η = σm,d / fm,d,fi and τd / fv,d,fiEN 1995-1-1 6.1.6, 6.1.7 · kernel eurocode/fire/timber/TimberFireBendingStress.kt:11, eurocode/fire/timber/TimberFireShearStress.kt:4-12

Lateral-torsional buckling in fire runs for solid timber only; glulam reads Unavailable. Statiko first finds an effective length from the ambient critical moment, then the critical stress of the residual section:

lef = 0.78 · b2 · E0,05 / (h · σm,crit), with σm,crit = Mcr / W ; σm,crit,fi = 0.78 · bfi2 · E0,05 / (hfi · lef)EN 1995-1-1 6.3.3 (6.32) · kernel timber/TimberFireLtbEffectiveLength.kt:6-24, eurocode/fire/timber/TimberFireCriticalBendingStress.kt:4-28

kcrit then follows the branches of EN 1995-1-1 (6.34) from the relative slenderness λrel,m = √(kfi · fm,k / σm,crit,fi), which the kernel computes with kfi inside the root and for which no clause is cited, and the check is σm,d / (kcrit · fm,d,fi) (eurocode/fire/timber/TimberFireKCrit.kt:5-26, eurocode/fire/timber/TimberFireReducedCrossSectionVerification.kt:166-203). A top flange restrained by a slab makes this check Not evaluated with the timber reason Top flange laterally restrained: kcrit = 1.0 (EN 1995-1-1 6.3.3(5))., the sentence the ambient timber check uses.

Timber fire uses the CEN values only: for any other design country the timber fire result reads Unavailable. A result with an Unavailable part, such as glulam lateral-torsional buckling, is shown as partial, never as a pass.

Concrete: tabulated data

A single span on two hinged supports uses Table 5.5. A beam with more than one span uses Table 5.6, because Statiko does not redistribute moments. A cantilever, or a single span with a fixed end, reads Unavailable. The check compares the beam width b with bmin, the smallest width of the row (column 2), and the axis distance a with amin, for the required resistance. amin is read from the column your width reaches; the check detail names it in the row Column for the axis distance.

Table 5.5bmin / amin (mm), columns 2 to 5
R3080 / 25120 / 20160 / 15200 / 15
R60120 / 40160 / 35200 / 30300 / 25
R90150 / 55200 / 45300 / 40400 / 35
R120200 / 65240 / 60300 / 55500 / 50
R180240 / 80300 / 70400 / 65600 / 60
R240280 / 90350 / 80500 / 75700 / 70

Source: EN 1992-1-2 5.6.2, Table 5.5; kernel eurocode/fire/concrete/ConcreteFireBeamTables.kt:6-14 (Table 5.6 at :16-24).

a = cnom + φlink + φ / 2 ; am = Σ As,i · ai / Σ As,i (several layers) ; asd = a + 10 mm (corner bars of a single layer, when the beam width is at most the width of the corner-bar column)EN 1992-1-2 5.2(14), 5.2(15) (5.5), 5.6.1(8) · kernel eurocode/fire/concrete/ConcreteFireTabulatedBeam.kt:12-36

amin is interpolated linearly between columns (5.2(12)). Custom minutes use the next table row at or above; above R240 the check reads Unavailable. Each bar must also meet the R30 value for its width (single layer) or half the average (several layers), as 5.2(17) requires. The tables hold for three-sided exposure at the reference load level ηfi = 0.7 (5.2(3)), for the Eurocode design country only. Four-sided exposure, other design countries, circular sections, concrete above C50/60 and density above 2600 kg/m³ read Unavailable. A continuous beam at R90 and above that needs the top-reinforcement rule of 5.6.3(3), or Table 5.7 at R120 and above, reads Unavailable, never Pass. The 500 °C isotherm method is not available in this version.

θ_a,cr θ_g θ_a b_fi × h_fi d_ef on exposed faces a b
Figure 22.1 · Steel heating against the critical temperature, the timber residual section, and the concrete width b and axis distance a.

What you see

Fire results appear in the window's Fire verification group and in the report. With fire input, steel, timber, glulam and concrete beams also list Fire verification at the end of their checks column, marked as the fire design situation.

Every fire result is Available, Unavailable with its reason, Invalid input, or Calculation failed. It is never a faked pass.

Source: spec/beam/fire.md rules 18, 33, 35, 38, 42, 43, 46 and 50.

Part V

Reference

Chapter 23

AI agents: the Statiko MCP server

Statiko includes a Model Context Protocol (MCP) server, so an AI agent such as Claude can work with your beam projects: create or open a project, read and edit the beam, undo and redo, save, read the result with every check and the moment, shear and deflection lines, and export the PDF report. The agent uses the same project, calculation and report code as the app, so its numbers, verdicts and PDF are the app's. This chapter shows how to switch the server on, how to connect an agent and what the agent can do.

How it works

The installed Windows app starts the server when an agent's client runs Statiko.exe mcp. It opens no window and talks to the client over standard input and output on your own computer. The server is named statiko and carries the app's version.

Not available in this version: a hosted remote server, Android and macOS, any transport other than stdio, per-agent permission levels, and fire design through the server.

Source: spec/mcp/server.md rules 3, 8, 11–13 and Scope; spec/beam/fire.md Scope.

Switching the server on

Open Settings › General. On the Windows desktop the area AI agents (MCP) sits after Interface language and Theme. Android has no such area.

ControlWhat it does
Let AI agents use StatikoSwitches the server on. Off by default.
Project folderThe only folder the agent may read and write. Shows “No folder chosen” until you pick one.
Choose folder…Opens a folder chooser; cancelling keeps the current folder.
Copy configurationOne button per client: Claude Desktop, Claude Code, Cursor, Codex, Gemini CLI, VS Code (Copilot). Copies that client's configuration with the installed Statiko.exe path filled in and shows “Copied”.

The Copy configuration buttons need the installed app; on a development build they are disabled with “Install Statiko to copy a configuration”. If another program holds the clipboard you see “The configuration could not be copied to the clipboard.” Settings › Reset switches the server off and clears the folder.

Source: spec/mcp/server.md rules 10, 40–47.

Connecting an agent

  1. Install Statiko with the Windows installer.
  2. In Settings › General › AI agents (MCP), tick Let AI agents use Statiko and click Choose folder… to pick your project folder.
  3. Click the Copy configuration button for your client.
  4. Paste the configuration where the client reads it (table below) and start the client. The client starts Statiko.exe mcp itself.
ClientWhere to paste it (Windows)Configuration
Claude Desktop%APPDATA%\Claude\claude_desktop_config.json{"mcpServers": {"statiko": {"command": "<exe>", "args": ["mcp"]}}}
Claude Code.mcp.json in a project, or claude mcp add-json{"mcpServers": {"statiko": {"type": "stdio", "command": "<exe>", "args": ["mcp"]}}}
Cursor%USERPROFILE%\.cursor\mcp.json or .cursor\mcp.jsonas Claude Code
Codex%USERPROFILE%\.codex\config.toml[mcp_servers.statiko], command = "<exe>", args = ["mcp"], one per line
Gemini CLI%USERPROFILE%\.gemini\settings.json or .gemini\settings.jsonas Claude Desktop
VS Code (Copilot).vscode\mcp.json or the user mcp.json{"servers": {"statiko": {"type": "stdio", "command": "<exe>", "args": ["mcp"]}}}

<exe> is the installed Statiko.exe path; the button fills it in, correctly escaped.

When the server will not start

The server refuses to start and writes one line to standard error when the settings file cannot be read (“Open Statiko once and check Settings › General › AI agents (MCP).”), when it is switched off, when no project folder is chosen, or when the folder no longer exists. Each message tells you which setting to fix.

Source: spec/mcp/server.md rules 10, 41–45 and Client configurations.

What the agent can do

The server offers fourteen tools. When a project has a single analysis and a single member, the agent does not need to name them.

ToolPurpose
list_projectsLists the .statiko files in the project folder or a subfolder
create_projectCreates a new beam project from Statiko's template and saves it; never overwrites an existing file
open_projectOpens a project and returns its summary
close_projectCloses the project; refuses with unsaved changes unless told to discard them
get_projectReturns the summary: name, input revision, unsaved changes, undo and redo, design code and analyses
get_beamReturns the beam or column input: material, section, supports, loads, self-weight, combination and limits
list_choicesLists allowed values: design countries, steel and timber grades, profile catalogues and profiles, support kinds, load actions and axes, combinations
edit_beamApplies a batch of edits as one Undo step, with the same rules as the app's screens
undo, redoUndo or redo the last edit, as in the app
save_projectSaves the project; a file changed since it was opened is a conflict and never overwritten
get_resultsWaits for the calculation (30 s by default, at most 120 s) and returns the verdict, reactions and every check with title, clause, status, reason, utilisation and governing combination
get_stationsWaits as get_results does and returns the lines the app's graphs draw for the selected combination: position, deflection, rotation, moment and shear at every station, and the final deflection line where the app draws one. Beam analyses only
export_reportWrites the PDF report as the app's export does, in English, Danish or Serbian Cyrillic, and answers with the path it wrote

Two read-only resources are also offered: statiko://project, the project summary, and statiko://results/{analysisId}, the latest result without waiting.

The edits edit_beam accepts are: rename the project, set the profile, steel or timber grade, set, add or remove a support or load, self-weight, top flange restraint, combination, deflection limits, design code and load duration. The same tools work on a column analysis, with the edits a column allows.

Source: spec/mcp/server.md Tools table and rules 24–39e and 48; tool descriptions in mcp/.

Folder, units and answers

Source: spec/mcp/server.md rules 15–23.

Chapter 24

Notation, units and glossary

This chapter is the reference for the symbols, units and words Statiko shows on screen and in the PDF report. Use it when a symbol in a check, a graph or the report is unfamiliar, when you want to change units, or when you need to know which direction counts as positive. Every symbol is drawn from one notation source shared by the app and the report, so a symbol means the same thing everywhere.

How symbols are written

Source: CODING_GUIDELINES.md, Engineering notation and reports; spec/beam/structural-system-drawing.md rules 11, 12; spec/beam/checks-column.md rule 7; spec/beam/report.md rules 34, 58.

Axes and sign convention

The report's Basis of design states the convention: “Loads and displacement are positive downward; moments are positive counter-clockwise; sagging moment is positive and drawn up. Positive shear is drawn up.”

Source: resources ReportStringsEn axes and sign convention text; spec/beam/structural-system-drawing.md rules 11, 13; spec/beam/concrete-report.md rule 9; resources notation AnalysisNotation.kt.

Units

Choose units in Settings › Units. The Defaults tab holds the Metric or Imperial preset; the Advanced tab can “Override input, display and PDF units per app area. Unset fields use the Defaults tab.” The report uses the same units and decimals (see Chapter 14).

QuantityMetric defaultImperial defaultDecimalsChoices
Lengthmft2mm, cm, dm, m, in, ft, yd
Displacementmmin1mm, cm, dm, m, in, ft, yd
ForcekNkip2N, kN, lbf, kip
Force / LengthkN/mlbf/ft2N/mm, N/m, kN/m, lbf/in, lbf/ft
MomentkNmkip·ft2Nmm, Nm, kNm, lbf·ft, lbf·in, kip·ft
Inertiacm⁴in⁴0mm⁴, cm⁴, m⁴, in⁴, ft⁴
Self weightkg/mlb/ft2kg/m, g/m, lb/ft, oz/ft
Densitykg/m³lb/ft³0kg/m³, g/m³, lb/ft³, lb/in³
StressMPaksi1Pa, kPa, MPa, psi, ksi
Timeminmin0s, min, h
Temperature°C°F0°C, K, °F
Rotationradrad8mrad, rad, °
Areacm²in²2mm², cm², m², in², ft², yd²
Warping constantcm⁶in⁶2m⁶, cm⁶, mm⁶, in⁶, ft⁶
Section moduluscm³in³2mm³, cm³, m³, in³, ft³
FrequencyHzHz2Hz, kHz
Bending stiffnessMNm²kip·in²2Nm², kNm², MNm², kip·in²

The Advanced tab groups overrides by area: Cross-section / detailing (length, recommended mm or in), Supports (length), Loads (length, force, force per length, moment, self-weight) and Results (displacement, stress, rotation). The Results area sets rotation to mrad with 2 decimals, which is why the Rotation graph shows mrad.

Other units you may see: ‰ for concrete strains, 1/m for the steel section factor Am/V, W/(m·K) and J/(kg·K) for thermal properties. The AI agent interface uses SI base units only (see Chapter 23).

Source: reports/units UnitDisplayQuantity.kt and UnitPreferenceArea.kt; project unit MeasurementUnit.kt; resources UnitStringsEn.

Symbols: actions, combinations and results

SymbolMeaningUnitWhere
Gk, QkCharacteristic permanent and variable actionkN, kN/m, kNmLoads, report 3.1
γG, γQ, γG,sup, γG,infPartial factors on actions–Design code, report 3.2
ξ·γG,supReduced permanent factor of 6.10b–Report 3.2
ψ0, ψ1, ψ2Combination, frequent and quasi-permanent factors–Report 3.2
KFIConsequence-class factor–Basis of design
6.10a, 6.10bEN 1990 ULS (STR/GEO) combinations–Combination names
6.10EN 1990 ULS (STR/GEO) combination of the Serbian annex–Combination names
6.14b, 6.15b, 6.16bCharacteristic, frequent, quasi-permanent SLS combinations–Combination names
6.11a/bAccidental (fire) combination–Fire
P, M, qPoint load, moment, distributed loadkN, kNm, kN/mLoad cards, report drawing
x, x1, x2Position along the beam; start and end of a loadmLoads, graphs
ey, ezLoad eccentricitiesmmLoad cards, report 3.1
LSpan; L/n deflection limitmDrawing, Design code
V, M, θ, δ, TShear, moment, rotation, deflection, torsionkN, kNm, mrad, mm, kNmResult graphs
ϕAngle of twistmradTorsion graph (Twist)
f1, fnFirst and n-th natural frequencyHzNatural Frequency graph, Eigenfrequencies
flimFrequency limit from the project settingsHzEigenfrequencies
w, wlimDeflection and its limitmmDisplacements
uinst, ufinInstantaneous and final deflection (timber)mmDeflection graph, Displacements, report 6.1
MEd, VEd, TEdDesign moment, shear, torquekNm, kN, kNmChecks
McrElastic critical moment for lateral-torsional bucklingkNmMoment graph header, LTB check
ηUtilisation ratio–Every check

Source: resources notation CombinationNotation.kt, ActionsNotation.kt, AnalysisNotation.kt, SectionNotation.kt, BeamCheckNotation.kt.

Symbols: steel and timber

SymbolMeaningUnitWhere
fy, fuSteel yield and ultimate strengthMPaReport 2.1, steel checks
γM0, γM1, γM2Steel partial factors: cross-section, instability, fracture–Report 2.1; γM1 in LTB
ε, c/tClassification strain factor, plate slenderness–Report 2.2 classification
Wpl, Wel,min, WeffPlastic, minimum elastic and effective section moduluscm³Bending check
Mc,RdBending resistancekNmBending check
Av,z, Vpl,Rd, Vpl,T,RdShear area, plastic shear resistance (with torsion)cm², kNShear check
hw, tw, η, 72 ε/ηWeb height and thickness, shear factor, web slenderness limitmm, –Shear Buckling Resistance
ρ, My,V,RdHigh-shear reduction and reduced moment resistance–, kNmBending check, report 5.3
αLT, λ̄LT, ΦLT, χLT, Mb,RdLTB imperfection factor, relative slenderness, Φ, reduction factor, buckling resistance–, kNmLTB check
TRd, τt,Ed, τw,EdTorsion resistance, St Venant and warping shear stresskNm, MPaTorsion check
Mw,Ed, Mz,EdWarping moment, minor-axis momentkNmBending and LTB cards
A, Iy, Iz, It, Iw, Wel,y, Wpl,y, iy, izArea, second moments, torsion and warping constants, section moduli, radii of gyrationcm², cm⁴, cm⁶, cm³, cmReport 2.2, Profile view
fm,k, fv,k, fc,90,kTimber characteristic bending, shear and perpendicular compression strengthMPaReport 2.1
E0,mean, E0,05, ρmeanTimber stiffness and densityMPa, kg/m³Report 2.1
γM, γ3Timber partial factors–Report 2.1, Design code
kmod, kh, ksys, kdefModification, size, system and deformation factors–Timber checks, report 2.1
σm,y,d, fm,dDesign bending stress and strengthMPaTimber Bending
τv,d, fv,d, kcr, befDesign shear stress and strength, crack factor, effective widthMPa, –, mmTimber Shear
τtor,d, kshapeTorsion stress, shape factorMPa, –Timber Torsion
σm,crit, λrel,m, kcritCritical bending stress, relative slenderness, LTB factorMPa, –Timber LTB
lef, Aef, kc,90, σc,90,d, fc,90,dEffective bearing length and area, bearing factor, stress and strengthmm, mm², –, MPaBearing check

Source: resources notation BeamCheckNotation.kt, SectionNotation.kt, TimberNotation.kt, DesignCodeNotation.kt.

Symbols: concrete and fire

SymbolMeaningUnitWhere
fck, Ecm, fcdConcrete characteristic and design strength, modulusMPaConcrete report 2.1, Bending
fyk, fydReinforcement characteristic and design yield strengthMPaConcrete report 2.1, Bending
γC, γS, αcc, αct, cot θConcrete partial factors, coefficients, strut angle–Concrete Basis of design
d, As,t, As,cEffective depth, tension and compression reinforcementmm, mm²Concrete section properties
cmin,dur, ΔcdevDurability cover, execution deviationmmConcrete report 2.1
x, εcu, εs,max, Cc, Cs, TsNeutral-axis depth, strains, internal forcesmm, ‰, kNBending + and −, flexure figure
VRd,c, VRd,s, VRd,maxShear resistances without links, with links, strutkNConcrete Shear
σc, σsConcrete and reinforcement stressMPaStresses
wk, sr,maxCrack width, maximum crack spacingmmCrack width
lbd, l0Anchorage and lap lengthmmAnchorage, Laps
Efi,d, Rfi,d,0, μ0Fire design effect, resistance at time zero, degree of utilisationkNm, –Steel fire
κ1, κ2, γM,fiFire adaptation factors and partial factor–Steel fire
θa, θa,crSteel temperature and critical temperature°CSteel fire
Am/VSection factor1/mSteel fire
dp, λp, cp, ρpProtection thickness, conductivity, specific heat, densitymm, W/(m·K), J/(kg·K), kg/m³Steel fire protection
Mfi,t,Rd, Vfi,t,Rd, Mb,fi,t,Rd, χLT,fiResistances in fire at time tkNm, kN, –Steel resistance method
dchar,n, def, bfi, hfiNotional and effective charring depth, residual width and heightmmTimber fire
kmod,fi, fm,d,fi, fv,d,fiFire modification factor and design strengths–, MPaTimber fire
hpCladding thicknessmmTimber fire cladding
bmin, a, aminMinimum width, axis distance and its minimummmConcrete fire
R30 … R240Required fire resistance classminFire inputs

Source: resources notation ConcreteNotation.kt, SteelNotation.kt, TimberNotation.kt; spec/beam/concrete-report.md rules 4–9; spec/beam/fire.md rules 20–47.

State words

WordMeaning
Results current · <combination>The shown result belongs to the current input
Calculating…A calculation is running; results update automatically
Results outdatedYou changed the input after the shown result
Invalid inputA field holds a value that cannot be calculated
Not calculatedThere is nothing to calculate yet, for example no loads and self-weight off
Calculation unsupported / failed / unavailableThe engine does not cover the model, broke on it or could not run
Pass / FailA real verdict with its utilisation
GoverningThe evaluated check with the greatest utilisation
Not evaluated / Not relevantThe check does not apply to this beam; never a pass
Unsupported / Unavailable / Failed calculationA check the engine does not cover, could not give, or broke on
Not checkedThe report's word for a check without a verdict
Resistance satisfied / not satisfied; Partial resultFire verdicts

Source: spec/beam/workspace-shell.md rules 20–25; spec/beam/checks-column.md rules 9, 12, 14; spec/beam/report.md rule 11; spec/beam/fire.md rules 10, 42.

Chapter 25

Scope, editions and limitations

This chapter states what Statiko designs, which Eurocode editions and National Annexes it uses, where it uses its own finite-element method and where it leaves Eurocode. Read it before you rely on a result for a member type or a country the chapter does not name. The Eurocode references tile on the hub's Documentation page opens this chapter.

What Statiko designs

Statiko designs single beams: steel (classes 1 to 3), timber, glulam and reinforced concrete, each with its normal design and its fire design. One beam is analysed as a line of beam elements on its supports, with its loads, combinations, checks and PDF report (Chapter 16).

Not in Statiko:

Source: statiko spec/guide.md › Scope; this guide's chapters 16 to 22.

Eurocode editions

Statiko calculates with the first generation of the Eurocodes, in the editions below. The report states the edition of the design code and of the basis of design on its Basis of design page (Chapter 14).

PartEditionUsed for
EN 1990EN 1990:2002 + A1:2005Basis of design, load combinations (Chapter 15)
EN 1993-1-1EN 1993-1-1:2005 + AC:2009Steel checks (Chapter 18)
EN 1993-1-5EN 1993-1-5:2006 + AC:2009The shear factor η (Shear)
EN 1995-1-1EN 1995-1-1:2004 + AC:2006 + A1:2008Timber and glulam checks (Chapter 19)
EN 1992-1-1EN 1992-1-1:2004 + A1:2014Concrete checks (Chapter 20)
EN 1991-1-2EN 1991-1-2:2002Fire actions (Fire actions)
EN 1993-1-2EN 1993-1-2:2005Steel in fire
EN 1995-1-2EN 1995-1-2:2004Timber and glulam in fire
EN 1992-1-2EN 1992-1-2:2004Concrete in fire

Source: resources localization/design/DesignStrings.kt:34,37,44; resources ConcreteStringsEn.kt:459; engineering SteelShearEtaProvenance.kt:3; statiko ai/eurocode/sources/register.tsv (fire parts); reports reportBasis.kt:74-75.

National Annexes

A project has one design code (Chapter 5). The choices are:

Concrete beams do not calculate under Sweden (SS EN), because the Swedish National Annex to EN 1992-1-1 is not in Statiko yet. Norway is not a design code choice, and there is no United Kingdom National Annex.

Source: project domain/design/AnnexDesignCountry.kt:3-9; resources DesignStringsEn.kt:24,40,60-62; spec/beam/concrete-workspace.md rule 4.

Where Statiko uses its own finite-element method

Where Eurocode leaves the method to the designer or gives no formula, Statiko uses its own finite-element method, and the guide names it each time:

Source: statiko ai/architecture/engineering-rules.md:5-9; engineering fem/ltb/CriticalBucklingCalculator.kt:39.

Results beyond Eurocode

One result is marked beyond Eurocode in the check details and the report: Finite-element shear area, beyond Eurocode. Statiko uses it for zee and solid sections, welded channels and boxes with inclined webs, for which EN 1993-1-1 6.2.6(3) gives no shear area (Shear).

The steel torsion resistance TRd = Wt · (fy / √3) / γM0 is Statiko's own form; the utilisation follows TEd/TRd ≤ 1 of EN 1993-1-1 6.2.7 (Torsion).

Source: resources ReportStringsEn.kt:57; reports steelReportCrossSection.kt:77; engineering steel/SteelShearArea.kt:12-151, steel/SteelTorsionCalculator.kt:33-36.

Limits of this version

Each calculation chapter lists what this version does not check. A check outside these limits reads Unsupported or Unavailable, never Pass.

Source: this guide's chapters 16, 18, 19 and 20.