Chapter 7
Concrete beams
A concrete beam is modelled in two places. The concrete cross-section window holds the shape, the reinforcement, the stirrups, the materials, the cover and the serviceability inputs. The workspace inspector holds the shear angle, the T-flange shear inputs and the optional anchorage and lap details. This chapter walks through both, in the order you normally fill them in.
Creating a concrete beam
In the Create Beam Analysis dialog the Material field offers Steel (tagged EN 1993-1-1) and Concrete (tagged EN 1992-1-1); Steel is the default. Choose Concrete, set the Beam Length and create the beam.
A new concrete beam starts with a rectangular section h 600 × b 400 mm, concrete C30, reinforcement steel Y-550 with ductility class B, cover 30 mm, stirrups Ø8 at 200 mm, 2 Ø16 at the top and 3 Ø16 at the bottom, and the default detailing settings. Self-weight is on: its line weight is the section area times the concrete density.
You can also turn an existing beam into a concrete beam: open the cross-section window and choose the Concrete tab (Chapter 6). There is no concrete catalogue; the tab opens the concrete editor on Rectangular with its defaults.

Source: spec/beam/concrete-workspace.md rules 1–2; spec/beam/concrete-section.md rules 1, 3, 6.
The concrete cross-section window
The title reads Concrete cross-section — Rectangular (or T, Circular) and the subtitle names the shape and concrete class, for example Rectangular · C30. The footer shows C30 · Y-550, or Invalid input, with Cancel and Apply. On desktop, and in any window at least 840 dp wide, the window has three columns. The left column holds the material tabs and the shape list, each shape with its glyph. The centre column shows the section drawing large, elevation A under it and the properties under that. The input panel on the right has the tabs Section (dimensions, longitudinal and shear reinforcement), Materials, Carbon, Durability and service and Fire. In a narrower window everything is one column.
Shape and dimensions
Choose Rectangular, T or Circular in the shape list, or in a narrow window in the choice above the dimensions. Changing the shape loads that shape's defaults and keeps your materials. All dimensions are in mm.
| Shape | Dimensions and defaults | Reinforcement default |
|---|---|---|
| Rectangular | h 600, b 400, cover 30 | Top 2 Ø16, bottom 3 Ø16, c 46; stirrups Ø8 at 200 |
| T | h 600, Flange width bf 800, Flange thickness hf 150, Web width bw 300, cover 30 | Flange 2 Ø16, web 3 Ø16, c 46; stirrups Ø8 at 200 |
| Circular | Diameter D 600, cover 30 | 8 Ø20 on a ring of radius 252 to the bar centres; ties Ø8 at 190 |
Longitudinal reinforcement
A rectangular section has Top reinforcement and Bottom reinforcement; a T section has Flange reinforcement and Web reinforcement. Each group is a list of rows with Count n, Size Ø and Axis distance c. A group with several rows adds the row count to its title.
- Add new copies the row with the largest c and places it at c + c / rows. A new row in an empty group is 2 Ø20 at c 48.
- Changing a bar size moves c by ΔØ/2, so the bar keeps its clearance.
- You can remove rows down to none.
A circular section has one ring with Count (a whole number, at least 3), Size and Radius r; a size change moves r by −ΔØ/2.
Shear reinforcement
Stirrup reinforcement is on by default, with Stirrups size and Stirrups spacing. Untick it and the size and spacing are disabled, no stirrup is stored and none is drawn. Cot(Θ) offers 1, 2, 2.5 and Custom (1 to 2.5); the default is 2.
Source: spec/beam/concrete-section.md rules 1–5; spec/beam/cross-section.md rule 5.
Materials
Concrete strength offers C12 to C90 and Custom; the default is C30 (C30/37). Cylinder compressive strength fck, Cube compressive strength fck,cube and Density are editable only for Custom. A class weighs 25 kN/m³, reinforced concrete by EN 1991-1-1 Table A.1 note 1, so its density is 25 000 / 9.81 = 2548.4 kg/m³. The older classes C8, C28, C32 and C100 open and show in older projects but are not offered.
Reinforcement steel offers Y-550, K-500 and Custom; the default is Y-550 with fyk 550 MPa and Es 200 000 MPa, editable only for Custom. Ductility class is A, B or C, default B.
The Carbon tab holds the card Product stage carbon (A1-A3) with Concrete factor in kg CO₂e/m³ and Reinforcement factor in kg CO₂e/kg, each with its Factor source. They start from the beam's saved factors, else from Boverkets klimatdatabas 02.07.000: the ready-mix row of the strength class (C12/15 and C16/20 have none and start empty), which follows the class while you have not typed a factor, and reinforcement 0.745 (6000000154). The lines under them give the concrete volume (gross area × length) and the longitudinal bars' mass, each with its footprint, and the total. Apply saves typed factors with the section.
Source: spec/beam/concrete-section.md rule 6.
Cover, durability and serviceability
Cover and durability
This group holds Concrete cover, Maximum aggregate size (default 16 mm), Exposure class X0 to XA3 (default XC1, Dry or permanently wet), Durability minimum cover cmin,dur and Execution deviation Δcdev.
When you pick an exposure class, Statiko sets cmin,dur and Δcdev for the project's National Annex and sets the cover to cnom = cmin,dur + Δcdev. An XF or XA class leaves all three unchanged.
| National Annex | cmin,dur table | Δcdev |
|---|---|---|
| Denmark | DS/EN 1992-1-1 DK NA Tabel 4.4N NA | 5 mm |
| Eurocode, Sweden, Serbia, Custom | EN 1992-1-1 Table 4.4N, S4 (Eurocode recommended) | 10 mm |
cmin,dur and Δcdev are standard value pickers: they offer the standard's values and Custom last, which opens a number field. A derived value shows its source, for example XC1 · Table 4.4N (Denmark XC1 · Table 4.4N NA), and a note naming the annex, Eurocode recommended or DS/EN 1992-1-1 DK NA. A stored value that matches no choice shows as Custom. A new concrete member starts from the XC1 values of the project's annex.
Serviceability
The Serviceability group is collapsed by default. It holds Cement class (Slow, Normal, Rapid; default Normal), Relative humidity (Inside 50 %, Outside 80 %, Custom 0–100; the default 70 % shows as Custom), Loading age t0 (default 28 d), Design age (50 years, 100 years, or Custom above t0; default 50 years) and Crack width limit wmax. wmax follows the exposure class from Table 7.1N (Denmark Tabel 7.1 NA), 0.4 mm for XC1; an XF or XA class leaves it. The deflection limit is set in the design code (Chapter 5).

Source: spec/beam/concrete-section.md rules 7–9.
Properties, drawing and Apply
The properties are Effective depth d, Tension reinforcement area As,t, Compression reinforcement area As,c, Area of cross section A, and Iy and Iz. Statiko calculates them on every valid change; a value the engine does not give shows Unavailable, never 0.
The section drawing shows the outline to scale, the dashed cover line, the stirrup, the bars, the overall width and height, callouts such as 2 Ø16 and Ø8 stirrups / 200 c/c, a legend and Dimensions in mm. Elevation A below it shows the beam at its length with supports and point loads, the section cut, the stirrups and the bar lines with a dimension chain.
Each field is checked as you type. The messages are Must be greater than zero., Cover and stirrup must fit inside the section., for a T Web width must not exceed flange width., Flange thickness must be less than height. and Cover and stirrup must fit inside the web and flange., for a circle Enter a whole count of at least 3. and Cover, stirrup, bar and radius must fit inside the section., for rows Enter a non-negative whole count., and Cot(Θ) must be between 1 and 2.5. While a field is invalid the drawings stay at the last valid geometry, dimmed, with Last valid geometry and Correct the marked field to update the drawing., and Apply is disabled.
Apply writes the section, the materials and the detailing settings in one project edit, undone in one step. Cancel, close, Esc and Back leave the analysis unchanged; an edited draft asks Discard changes? first. There is no create, rename or delete for concrete profiles: the section belongs to the member.

Source: spec/beam/concrete-section.md rules 10–16.
Detailing inputs in the inspector
The inspector of a concrete beam has a Shear group with Cot(Θ) (1, 2, 2.5 and Custom 1 to 2.5), the same value as in the window.
On a T section the group adds the checkbox T-flange/web longitudinal shear, off by default. Switch it on to show T-flange · compression (1.0, 2.0, Custom 1.0 to 2.0), T-flange · tension (1.0, 1.25, Custom 1.0 to 1.25), each noted Eurocode recommended, and Asf / sf in mm²/m. It starts at 2.0, 1.25 and 0.
Tick Specify anchorage and lap details to open the Anchorage and Laps groups, for rectangular and T sections. A circular section has no detailing inputs.
Anchorage
Add anchorage adds a card for the first free bar and end, titled for example Bar 1 · Ø16 · Start. Each card has Force state (Tension, Compression), Bond condition (Good bond, Poor bond), End shape (Straight, Standard bend, Standard hook, Standard loop), Design stress σsd in MPa, Available length in mm, Mandrel diameter in mm (not for Straight) and Delete. A new card is Tension, Good bond, Straight, 0 MPa, 0 mm.
Laps
Tick Lap schedule is complete (including no laps) when the list is complete. Add lap adds a lap on the first bar. Each lap has the bar, start and end position, force state, bond condition, design stress, Bars lapped at section (< 25 %, 33 %, 50 %, > 50 %, Custom 0 to 100), Clear spacing between lapped bars in mm, Provided transverse reinforcement area in mm², the checkboxes Transverse reinforcement distributed in outer thirds, Required close-lap links provided and, under Compression, Compression-lap end bars provided, and Delete.
Every detailing field is validated by the engine; an invalid field shows its message, keeps the last valid input, and the checks show Invalid input. Each edit is one Undo step and the calculation runs automatically.

Source: spec/beam/concrete-workspace.md rules 5–11.
Design code and checks
For a concrete beam the Design code card shows EN 1992-1-1 · Concrete, and the dialog shows γc, γs, αcc and αct with Eurocode recommended values, editable under Custom values. The deflection limit is L/250, L/500 or Custom, default L/250.
The checks column lists Bending +, Bending −, Shear, Stresses, Crack width, Deflection, Anchorage, Laps, T-flange longitudinal shear (T sections only) and Torsion, each with its clause. How they are calculated is described in Chapter 20; reading them is described in Chapter 12. Concrete fire design is in Chapter 13.
Source: spec/beam/concrete-workspace.md rules 3, 4, 12.