Chapter 13

Fire design: inputs and checks

Fire design verifies that a steel, timber, glulam or concrete beam keeps enough resistance for the required fire period. You choose the required resistance and how the beam is exposed; Statiko takes the design effects from the fire combinations it already generates (EN 1990 6.11b) and runs the simple Eurocode method for the material. This chapter shows where the fire inputs are, what each one does and how to read the result. How the methods calculate is explained in Chapter 22.

Where the fire inputs are

The fire inputs live in the cross-section window, in the same draft as the profile. On desktop they are in the input panel's Fire tab, with the fire results under them; in a narrow window they sit under the profile. The region is titled Steel fire design (EN 1993-1-2), Timber fire design (EN 1995-1-2) or Concrete fire design (EN 1992-1-2).

  • Apply saves the profile and the fire inputs together. Cancel, close, Back and Esc ask once if you changed either: “The edited profile and fire inputs are discarded. The analysis stays as it was.”
  • The Fire overlay switch in the drawing header, on by default, draws the exposed faces, protection or charred layer on the section. Turning it off hides only the drawing and its legend.
  • The window's footer adds an available fire verdict to the profile status, for example “Class 1 · S235 · Resistance satisfied”.

Fire inputs belong to the beam, not the profile: choosing another profile keeps them. Inputs for another material stay dormant and come back if you switch back. A fire edit is a normal project edit with Undo and Redo, it is saved in the project file, and the beam recalculates automatically.

Source: spec/beam/fire.md rules 4–11.

Required fire resistance and exposure

Required fire resistance offers None, R30, R60, R90, R120 and Custom (minutes), which shows Custom fire resistance (min). None is the default for new beams and for older files: the beam then has no fire result, no fire card and no fire verdict. An empty or zero custom time gives “Enter the required fire resistance time (minutes).”

For steel and timber, Fire exposure offers Four sides (all around), Three sides + slab on top (steel: “… slab on top flange”) and Custom faces, which shows Left, Top, Right and Bottom under Custom exposed faces. Picking a preset ticks its faces; changing a face switches to Custom. Steel starts on four sides, timber on three.

Each fire combination is verified with its own design effects and the result names the governing one. You never type a fire moment or a reduction factor.

Source: spec/beam/fire.md rules 2, 12–16, 19.

Steel

The region opens with “μ0 = E_fi,d / R_fi,d,0 (EN 1993-1-2). The η_fi = 0.65 shortcut is not used.” and a notice on how far the section is supported: I and H sections have the full path, hollow sections are supported for heating, other open sections are partial, and circular hollow, round bar, angle and zee sections read Unavailable with the inputs disabled but kept.

  • At continuous support (κ2) applies the continuity factor at intermediate supports and fixed ends of a statically indeterminate beam. Under Custom faces, Slab on top flange (κ1) also appears and removes Top.
  • Protection type: Unprotected, Contour protected or Box protected. Protected shows the protection thickness dp, conductivity λp, specific heat cp and density ρp, all typed by you; there is no product list. For intumescent coatings the app shows Intumescent coatings are outside EN 1993-1-2 Eq. (4.27) simple heating — Unavailable.
  • Steel thermal properties: ca(θ) from EN 1993-1-2 3.4.1.2 with ρa = 7850 kg/m³ by default, or Custom ca and ρa. Initial steel temperature θ_a,0 is 20 °C by default.

Under Fire verification two methods sit side by side. The Critical temperature method shows μ0, κ1, κ2, γM,fi with its source, θa,cr, Am/V, the steel temperature at the required time, the margin θa,cr − θa and the verdict. The Resistance method shows Mfi,t,Rd, Vfi,t,Rd and Mb,fi,t,Rd with χLT,fi, each with its utilisation. The Steel fire verdict is the worse of the two, so neither can hide a failure.

Steel results appear in the cross-section window and in the report, and with fire input the steel checks list ends with a Fire verification card (EN 1993-1-2 4.2.3, 4.2.4) with the same note as the timber card; opening it shows the fire derivation and verdict in the check details. A Custom design country reads “Custom National Annex steel fire factors are not verified in Statiko.”

Steel cross-section window with R60 contour protection and both fire methods
Figure 13.1 · An IPE 220 at R60 with contour protection: the fire-exposed perimeter and the contour on the drawing, and the Fire tab scrolled below the protection values to Fire verification with the critical temperature method, the resistance method and the Steel fire verdict

Source: spec/beam/fire.md rules 20–35.

Timber and glulam

Timber and glulam use the reduced cross-section method, for rectangular sections and Eurocode recommended values only. Fire cladding is Unprotected or Gypsum plasterboard type A, which needs Cladding h_p.

The result shows four groups: Parameters (kmod,fi, dchar,n, def, bfi, hfi and the Charring phase), Design capacities (fm,d,fi, fv,d,fi), Cross-section checks (bending and shear ratios) and Stability checks (σm,crit, λrel,m, kcrit and the buckling ratio). The overlay draws the charred layer and residual section, and the cladding solid while effective and dashed after its fall-off time.

With fire input, the timber checks list ends with a Fire verification card (EN 1995-1-2 4.2.2) noting “Fire verification is the fire design situation; it is not part of the governing check.”

Timber checks column ending with the Fire verification card
Figure 13.2 · A C24 45×220 beam at R30 behind gypsum plasterboard type A: the timber checks column ends with the Fire verification card (EN 1995-1-2 4.2.2) and its note

Source: spec/beam/fire.md rules 36–43.

Concrete

Concrete uses the tabulated data of EN 1992-1-2 5.6 from the beam's own section, bars and supports. The region holds Fire exposure, Three sides + slab on top (default) or Four sides (all around), and the required fire resistance. There are no other fire fields.

The result compares the width b with bmin and the axis distance a with amin, and names the table (Table 5.5 · simply supported or Table 5.6 · continuous beam), the column and the Table row; a custom time uses the next row up. Each requirement reads OK or Fail.

The tables do not cover every case, and Statiko says so rather than guessing. These read Unavailable with their reason: a cantilever or a single span with a fixed end, four-sided exposure, a circular section, more than R240, concrete above C50/60, concrete above 2600 kg/m³, and the National Annexes of Denmark, Serbia, Sweden or a Custom country. A continuous beam at R90 or more that meets the width b and axis distance a reads Unavailable, because the top reinforcement rule over the supports is not verified; one that fails b or a reads Fail. Table 5.7 (R120 and above) is not verified either.

Concrete results appear in the cross-section window and the report, and with fire input the concrete checks list ends with a Fire verification card (EN 1992-1-2 5.6) with the same note as the timber card; opening it shows the tabulated derivation and verdict in the check details.

Source: spec/beam/fire.md rules 44–50.

Fire in the report

With fire input, the report's fire chapter (5.6 for steel, timber and glulam, 5.2 for concrete) prints at every detail level: the method, the section figure with its fire overlay, the inputs, the results and the verdict; steel prints both methods and the governing verdict. Without fire input the chapter keeps its one sentence, such as “Fire design according to EN 1993-1-2.” The Summary has one fire row, outside the governing check, and Basis of design prints the fire protection requirements you typed in the export form. A fire result that is Unavailable, Invalid or partial cannot be deselected in Custom. See Chapter 14.

Source: spec/beam/fire.md rules 51–55.