Chapter 9

Loads and self-weight

The Loads section lists every characteristic load on the beam: point loads, moments and distributed loads. Each load has a load action, which tells the EN 1990 combinations which partial and ψ factors apply. The section also holds the self-weight switch. This chapter shows how to add and edit loads, where a load acts over the section height, and what the load errors mean.

The Loads section and self-weight

The Loads section follows Supports in the inspector. Its header shows Sort by position and the number of loads.

Under the header, tick Include self-weight in G to add the beam's own weight to the permanent action G. A line then shows Characteristic self-weight: and the value from the current section, in your force-per-length unit. If the section cannot be resolved, a reason shows instead of the value. A new concrete beam starts with self-weight on; other new beams start with it off.

Source: spec/beam/loads.md rule 1; spec/beam/concrete-workspace.md rule 2.

Reading a load card

Load cards look and behave like support cards: a neutral border, lighter when closed and stronger when open or selected. Only one card is open at a time across Supports and Loads; Esc closes it.

  • A point load or moment shows two lines: the type and the load action, then the value and x with its position.
  • A distributed load shows the type and action, then a small span diagram: the end values above, the load shape on the member line, and x1 and x2 below. The shape may be uniform, sloped or change sign.

Values have no plus sign; negative values use the true minus −. Trailing zeros are dropped. A new load shows — for each value until you enter it.

Loads section with self-weight and three load cards
Figure 9.1 · The Loads section: Include self-weight in G with the characteristic self-weight, a sloped distributed load, a point load, a moment and the dashed Add load row

Source: spec/beam/loads.md rules 2–7.

Adding and editing loads

  1. Click Add load at the end of the section.
  2. Choose Point, Moment or Distributed. The new load takes the action Dead Load (G), its card opens and the first field has focus.
  3. Choose the load action in the select next to the type picker.
  4. Enter the values, each on its own row: for a point load x and F; for a moment x and M; for a distributed load x1, x2, q1 and q2.
  5. Press Tab or Enter. The calculation runs automatically.

Until its fields are valid, a new load is a draft: it sits last, the status is Invalid input, and the calculation runs without it. Changing the type keeps the action and the start position and clears values the new type does not have. The bin button Delete load sits on the card's last row.

The load action select lists Dead Load, the imposed-load categories A to H (for example A Domestic, residential areas, B Office areas, H Roofs), Wind Load, Snow Load and Custom Load, each with its glyph. Long names end with an ellipsis; the full name is in the tooltip. How each action enters the combinations is described in Chapter 15.

Cards keep their order while you edit. Sort by position orders them by x, or x1 for distributed loads, and is one Undo step. Tab moves through type, action, values, the application point buttons, ez (only when unlocked), ey and Delete, then into the next load card; after the last load it reaches Add load. On a phone a card opens without raising the keyboard.

Number fields accept digits, the minus sign and both decimal separators. An unfinished entry such as - or 1, keeps its text, marks the card and shows Enter valid numbers before calculating. Positions, forces, line loads, moments and self-weight use the Loads unit from Settings › Units › Advanced when you have set one.

Source: spec/beam/loads.md rules 8–12, 19–22, 25, 27.

Application point and eccentricity

Point and distributed loads have an application point that says where over the section height the load acts. The card shows Top, Middle, Bottom and a lock on one row, then the vertical eccentricity ez (ePz for a point load), then the lateral eccentricity ey. Moments have no application point.

  • Top is the top fibre above the centroid (zmax − zC), Middle is 0 and Bottom is the bottom fibre (zmin − zC), from the current section and not rounded. For an IPE 220 that is +0.11 m, 0 and −0.11 m.
  • While the lock is closed, the pressed preset drives ez and the field is disabled.
  • Open the lock to type your own ez; the presets are no longer marked.
  • Closing the lock again picks the preset that matches ez within 0.5 mm, or Top if none matches.
  • ey is 0 by default.

The tooltips read Attack Point Top, Attack Point Middle, Attack Point Bottom, Enable custom load attack point for LTB and Disable custom load attack point for LTB: the application point matters for lateral-torsional buckling (Chapter 17).

A new point or distributed load starts locked at Top. When you change the section, every locked load keeps its preset and takes the new height; your own values stay. If the section fibre heights cannot be found, the presets and lock are disabled with a reason on the card, such as Application point presets require a valid section., and ez keeps its value. An older distributed load with different start and end eccentricities shows Start and end eccentricities differ. The start values are shown; editing an eccentricity applies it to both ends.

Open point load card
Figure 9.2 · An open point load: x and F, the three application point buttons with the lock, ePz disabled, ey and the delete button

Source: spec/beam/loads.md rules 13–17.

A moment on a hinge

When a moment sits on a hinge (within 1 mm of its position), the card shows Acts on with Left of the hinge and Right of the hinge, default Right, and the hint The results differ by side. Choose the side the moment is applied to: each side belongs to a different part of the member. Moving the moment off the hinge hides the choice and keeps your side.

Source: spec/beam/loads.md rule 18.

Load errors and axial loads

A load must lie between the first and the last support, hinges and Free supports included. Otherwise the card turns to the danger colour and shows Load positions must be within the member bounds. under the position. A distributed load whose end is not after its start shows The end position must follow the start position. The status is Invalid input and the drawing marks the load.

An axial load from an existing file shows as a read-only card with its action, position and force and Axial loads are not editable yet. You cannot add axial loads in this version.

Source: spec/beam/loads.md rules 23, 24, 26.