Chapter 17
Lateral-torsional buckling
This chapter explains how Statiko checks lateral-torsional buckling, the sideways buckling and twisting of a beam whose compression flange is not held. It describes how the app finds the elastic critical moment Mcr over the whole member, and how Mcr then gives the steel reduction factor χLT and the timber factor kcrit. Use it to understand the values in the LTB check details and what the Top flange laterally restrained box changes.
Kernel paths in this chapter are under engineering/src/jvmAndAndroidMain/kotlin/statiko/engineering/ unless they begin with steel/, timber/ or verification/CriticalMomentResult.kt, which are under engineering/src/commonMain/kotlin/statiko/engineering/.
Critical moment as an eigenvalue
EN 1993-1-1 6.3.2.2(2) requires Mcr to be based on gross section properties and to take into account the loading conditions, the real moment distribution and the lateral restraints. The standard gives no formula for it. Statiko therefore computes Mcr with its own finite-element linear buckling analysis over the whole member. From the static moments, shears and loads of the combination it builds a stiffness matrix K and a geometric stiffness matrix KG, and solves the generalised eigenvalue problem:
fem/ltb/CriticalBucklingCalculator.kt:39The smallest positive eigenvalue λcr is the factor by which the combination's loads must grow before the beam buckles. The critical moment is that factor times the largest moment of the static solution:
verification/BeamCriticalMoment.kt:71Because the whole member, its real moment diagram, its supports and the height of each load enter the model, no equivalent uniform moment factor or effective length is needed.
What feeds the analysis
- The supports, hinges and loads of the beam and the selected combination (Chapter 15, Chapter 16).
- The Z offset of each point and distributed load: its height relative to the shear centre. A load above the shear centre lowers Mcr. Self-weight acts with zero offset.
- The section: Iy, Iz, the product of inertia, It, Iw, the shear centre and the monosymmetry constants, all from the section analysis.
- E and G of the material. For timber the eigenproblem uses the characteristic E0,05 and G05; for rectangular softwood G05 = E0,05/16 (Swedish Wood, Design of timber structures 1, 2016, p86; Centrum Hout, Houteigenschappen, 2014/3, p2).
- The Top flange laterally restrained box on the Member card (Chapter 8).
Source: calculation/BeamKernelModel.kt:15-41; verification/BeamCriticalMoment.kt:16-32; timber/TimberStabilityStiffnessResolver.kt:12-57.
The buckling model
Each node has four degrees of freedom: lateral displacement u, lateral slope u′, twist φ and warping φ′. The member is meshed with 50 equal divisions plus nodes at the supports and loads. At an internal hinge the right side gets its own lateral slope and warping; a hinged model that can move sideways as a mechanism is refused.
The elastic stiffness combines lateral bending, g · EIz times the Hermite beam matrix, with warping and St Venant torsion, for example:
fem/matrix/LateralTorsionalBucklingMatrices.kt:6-40fem/ltb/CriticalBucklingMatrixAssembly.kt:37The geometric stiffness of each element adds the moment M1 and shear V1 at the element start (giving the linear change of moment along it), every point load P with its height term (ez − y0), every applied moment, and every distributed load q with its height (ay − y0). The monosymmetry term is:
fem/ltb/CriticalBucklingMatrixAssembly.kt:40Here x0, y0 are the shear centre coordinates and βx, βy the section's monosymmetry constants, in the kernel's section axes.
Source: fem/dof/BeamLtbDofs.kt:3-10; fem/ltb/BeamLtbDofMap.kt:14-21; fem/ltb/LtbHingeStability.kt:9-30; fem/ltb/CriticalBucklingMatrixAssembly.kt:72-123.
Restraints and the eigenvalue solution
Every support that holds a vertical translation is a fork support: it fixes the lateral displacement u and the twist φ. A support that holds a rotation also fixes u′ and φ′. Restrained degrees of freedom are removed from K and KG. Discrete lateral restraints between supports and restraint over part of the length are not available in this version.
- K and KG are scaled by si = 1/√Kii.
- LAPACK
dsygvdsolves KG · x = μ · K · x with K as the positive definite matrix; λ = 1/μ. - Modes with |μ| ≤ n · ulp(1) · max|μ| are dropped.
- Each λ is refined by the Rayleigh quotient λ = (φTKφ) / (φTKGφ) with compensated summation, and the list is sorted.
- λcr is the first positive eigenvalue.
Source: fem/data/SupportRestraints.kt:57-68; linalg/LinAlgImpl.kt:8-71 (computeSymmetricDefiniteEigenvalues); fem/data/LTBData.kt:8. The non-symmetric path keeps only real, finite eigenvalues (linalg/realGeneralizedEigenvalue.kt:5-8).
The result is one of four kinds: computed, not computed (no moment, no positive eigenvalue or an unsupported section), unavailable (the native solver is missing) or failed calculation. Only a computed Mcr can give a result (verification/CriticalMomentResult.kt:3-11).
Steel: χLT and Mb,Rd
Statiko follows the general case of EN 1993-1-1 6.3.2.2.
steel/SteelMemberVerifier.kt:427steel/SteelMemberVerifier.kt:428steel/SteelMemberVerifier.kt:429-436steel/SteelMemberVerifier.kt:273-275Wy is the plastic modulus for Class 1 and 2 and the elastic modulus for Class 3. The buckling curve follows Table 6.4, general case:
| Section | h/b ≤ 2 | h/b > 2 |
|---|---|---|
| Rolled I | a (αLT = 0.21) | b (αLT = 0.34) |
| Welded I | c (αLT = 0.49) | d (αLT = 0.76) |
| Other sections | d (αLT = 0.76) | |
Source: steel/SteelLateralTorsionalCurve.kt:9-20; steel/SteelBucklingCurve.kt:3-9; EN 1993-1-1 Tables 6.3 and 6.4.
When you tick Top flange laterally restrained and no station moment of a combination is negative, that combination is covered: steel LTB is Not evaluated for it, by EN 1993-1-1 6.3.2.1(2), and no Mcr is computed. A combination with hogging anywhere is checked as normal.
When torsion produces a warping demand, Statiko checks LTB only on a simply supported single span, with the member interaction of SCI P385 3.2; on other beams the LTB check is Unsupported. The interaction, with kw = 0.7 − 0.2 · Mw,Ed/Mw,Rd, is:
steel/SteelMemberVerifier.kt:109-133Source: spec/beam/lateral-restraint.md rules 6 to 8; verification/SteelBeamChecks.kt:285-308, 567-568, 683-689.
Timber: kcrit
timber/TimberBeamUtilizationCalculator.kt:164timber/TimberBeamUtilizationCalculator.kt:174timber/TimberBeamUtilizationCalculator.kt:175-179timber/TimberBeamUtilizationCalculator.kt:43-44, 181ksys enters fm,d only, not the slenderness. For a covered combination kcrit = 1.0 by EN 1995-1-1 6.3.3(5); the fork supports provide the torsional restraint that clause also requires. Statiko does not use the effective lengths of Table 6.1: Mcr comes from the eigenvalue problem. Without a computed Mcr the timber LTB check is Unavailable.
What you see
The Lateral torsional buckling check card and its details show Mcr, αLT, λ̄LT, ΦLT, χLT, γM1 and Mb,Rd for steel, or σm,crit, λrel,m, kcrit and fm,d for timber (Chapter 12). The report prints the same derivation in its LTB section (Chapter 14).