Chapter 11

Result graphs

The result graphs show how the beam carries its loads: shear, moment, rotation, deflection, torsion and the natural vibration mode, plotted along the member for the load combination you have selected. Every curve is read from the same calculation result that the checks and the PDF report use, so what you see on the graph is exactly what the checks verify. This chapter explains the two graph views, what each part of a graph means, how the cursor readout works and what the graphs show while a calculation is running or cannot run.

Graph list and Dual-axis graph

The graphs fill the canvas of the beam workspace, under the Analysis tab. The canvas toolbar switches between two views:

  • Graph list shows each quantity on its own plot, one below the other or one at a time.
  • Dual-axis graph puts two quantities on one plot, with a ruler on each side, so you can compare them at the same position.

The same choice is in the View menu: View › Graph list and View › Dual-axis graph follow the toolbar and the toolbar follows the menu. On a phone both views are in the Results tab, which keeps the canvas toolbar with Dual-axis and shows the Graph list in Tabs by default (Chapter 4).

Source: spec/beam/graph-list.md rules 15–18; spec/beam/dual-axis-graph.md rule 14.

The six graphs

Graph list shows six graphs, always in this order:

GraphSymbolDefault unit and decimalsShown by default
ShearVkN, 2 decimalsYes
MomentMkNm, 2 decimalsYes
Rotationθmrad, 2 decimals (rad or ° also available)No
Deflectionδmm, 1 decimalYes
TorsionTmoment unit (torque) or rotation unit (twist)When the beam carries torsion
Natural Frequencyf1Hz, 2 decimalsFor an SLS combination

Units follow Settings › Units (see Chapter 24). Rotation is off at first; tick it to see it.

The selected load combination drives every curve, deflection included. With None selected the graphs show the characteristic actions with unit factors. Changing the combination counts as an edit: the curves go outdated for a moment and then show the new combination.

Some graphs only make sense in some cases, so the app never draws an empty or meaningless plot. Instead the graph's checkbox or tab stays visible, greyed out, with its reason:

  • Torsion: “No torsion: all loads act in the plane of the beam through the shear centre.”
  • Natural Frequency with a ULS, fire or None combination: “Natural Frequency is shown for SLS combinations.”
  • Any graph without a result: “No current result is available.”

Source: spec/beam/graph-list.md rules 1–7, 12, 13, 24.

Stacked and Tabs

In Graph list the two icons at the right end of the toolbar choose the layout:

  • Stacked shows the graphs one below the other. A row of six checkboxes above them lets you hide a graph and bring it back; each visible graph also has its own checkbox. Stacked is the default from 840 dp window width.
  • Tabs shows one graph at a time with all six tabs present. It is the default in narrower windows. A disabled tab keeps its reason.

View › Stacked / Tabs shares this choice. In the Dual-axis graph the layout icons are hidden and the menu item is disabled with “Choose Graph list to change its layout.”

Graph list with Shear and Moment plots
Figure 11.1 · The Graph list, Stacked, for a ULS combination: the checkbox row with Rotation unticked, the Natural Frequency reason, and the Shear and Moment plots with their badges and Mcr

Source: spec/beam/graph-list.md rules 15–18.

Reading a graph

Each graph is a flat panel on the workspace background with a thin line above it. Inside it you see:

  • the curve in the quantity's colour, with a soft gradient fill down to the zero line;
  • dashed vertical guides at the supports and other structural nodes, placed exactly where the structural system drawing above puts them, so positions line up;
  • a ruler with plain values and, once above it, the unit in brackets in the curve's colour, for example [kNm];
  • the largest and smallest values marked with a filled dot, a dashed drop line and a small boxed badge such as Mmax = 29.70 kNm or δmax = 12.4 mm. Badges move to a free side so they never cover each other or the curve's edge.

Values have no plus sign; negative values use the true minus “−”.

Two graphs add a reference:

  • Deflection draws the span limit line L/<limit> from the design code, but only for an SLS combination; other combinations have no limit line.
  • Natural Frequency draws the normalised mode shape for an SLS combination and shows the frequency in Hz in its badge. The shape's height is not a physical amplitude.

The Rotation graph includes both sides of a hinge.

The cursor readout

Move the pointer over a plot. A hollow ring appears on the curve at that position with a value badge beside it, and a small badge on the x axis reads x = <position>. The status bar never shows cursor values; it always shows the calculation state.

Source: spec/beam/graph-list.md rules 3–5, 8–12.

Controls in the graph headers

Four graphs carry extra information or controls in their header.

Torsion: Torque or Twist

A Torque / Twist switch chooses what the Torsion graph shows. Torque is the default. Twist plots the angle of twist ϕ along the beam in the rotation unit, with ϕmax and ϕmin badges. The choice lasts for the session and is not saved in the project file. The Dual-axis graph uses the same choice.

Natural Frequency: Mode and Animate

The Mode picker offers Mode 1 up to the number of computed modes, at most five. The badge shows that mode's frequency fn. Each new result returns to Mode 1. Tick Animate to see the shape swing: it repeats every two seconds whatever the frequency, while the axis stays fixed. Animate is off at first and lasts for the session.

Moment: Mcr

The Moment header shows Mcr = <value>, the elastic critical moment the lateral-torsional buckling check computed for the moment distribution of the selected combination (see Chapter 17). It is shown only when the check computed it; while calculating, or when it is not available, the header has no Mcr.

Deflection of timber and glulam: uinst and ufin

For a timber or glulam beam with a characteristic SLS combination selected, the Deflection graph adds a dashed curve ufin, the final deflection the final deflection check verifies, beside the instantaneous uinst. The header reads uinst = … / ufin = … and the cursor badge shows both. Other combinations and materials show uinst only.

Moment, Deflection and Natural Frequency plots for SLS
Figure 11.2 · An SLS combination with the pointer over Deflection: the hover ring and badges, the L/400 limit line, and Natural Frequency with the Mode picker and f1

Source: spec/beam/graph-list.md rules 25–32.

The Dual-axis graph

The Dual-axis graph draws two quantities on one plot with one shared zero line, a left ruler for the left curve and a right ruler for the right curve, each with its unit above it in the curve's colour. Use it to see, for example, where the shear crosses zero under a moment peak.

A row below the toolbar holds up to three selects; a preset shows only Compare:

  • Compare offers the presets Moment + Shear (default), Deflection + Rotation, Shear + Torsion and Moment + Deflection, then Custom.
  • Left and Right, shown for Custom, list all six quantities. The right select disables the quantity chosen on the left with “Already selected on the left.”

A preset or quantity without data stays in the list, disabled with the same reason as in Graph list, for example Shear + Torsion on a beam without torsion. The deflection ruler names the selected combination and shows the limit line only for an SLS combination. Your choice is kept for each analysis while the project is open; it is not saved in the project file.

Both curves get extreme badges and, under the pointer, a ring and a value badge each, sharing one x badge.

Dual-axis graph comparing moment and shear
Figure 11.3 · The Dual-axis graph, Compare = Moment + Shear: the kNm ruler on the left, the kN ruler on the right and the two-value cursor readout

Source: spec/beam/dual-axis-graph.md rules 1–11, 15.

While calculating and when there is no result

Statiko calculates automatically after every valid edit; there is no Calculate button. The graphs tell you which state the result is in, with the same words as the status bar:

StateGraph listDual-axis graph
First calculationThe empty frame (zero line, x axis, guides), a circular indicator and “Calculating…”“Calculating…”, no curves
Calculating with a previous resultThe previous curves dimmed, a progress line on the panel edge“Calculating…”, no curves
OutdatedCurves dimmed, “Results outdated”“Results outdated”, no curves
Invalid inputCurves dimmed, “Results outdated”, and “Enter valid numbers before calculating.” when a field holds an unreadable number, otherwise “Invalid input. Review the beam geometry and load.”The same sentence, no curves
Not calculated, Unstable, Failed, Unsupported, UnavailableThe state's sentence, for example “The beam is not stable with these supports and cannot be calculated.”, and no curveThe same sentence, no curves

Source: spec/beam/graph-list.md rules 19–23; spec/beam/dual-axis-graph.md rules 12–13; spec/beam/workspace-shell.md rules 20–25.