Chapter 18

Steel checks

This chapter explains how Statiko verifies a steel beam against EN 1993-1-1 for every ultimate limit state combination. It covers the partial factors of each National Annex, the cross-section classification, the resistances in bending, shear and torsion and how they interact, and where the stability check of Chapter 17 fits in. Use it to read the four steel check cards and their details, and to understand why a section is refused rather than passed.

Kernel paths in this chapter are under engineering/src/commonMain/kotlin/statiko/engineering/, except verification/SteelBeamChecks.kt and verification/limitedToBeamAxialScope.kt, which are under engineering/src/jvmAndAndroidMain/kotlin/statiko/engineering/.

How the steel checks run

For every ULS combination Statiko takes the station results of the static analysis (Chapter 16) and checks each station. It first resolves the design yield strength and the partial factors, classifies the section for strong-axis bending, refuses a Class 4 section, and picks the plastic or elastic modulus by class. It then produces four checks: Bending, Shear, Torsion and Lateral torsional buckling. Each check names its governing combination and position.

What feeds the checks: the profile and its manufacturing (rolled or welded), the steel grade and product standard, which give fy by thickness (Chapter 6), the design code with its country and steel robustness setting, the top flange restraint, and the loads with their offsets.

Source: verification/SteelBeamChecks.kt:160-517; ai/architecture/engineering-rules.md, Steel classification and effective-section boundary, Profile feasibility boundary.

Partial factors

National AnnexγM0γM1γM2
Eurocode1.01.01.25
Denmark1.11.21.35
Sweden1.01.01.1
Serbia1.01.01.25
Customthe values you enter in the Design code dialog

The Eurocode values are the recommended values of EN 1993-1-1 6.1. When you switch on steel robustness, every γM is multiplied by 1.2:

γM,used = 1.2 · γM (robustness on)kernel steel/SteelDesignFactorResolver.kt:6-13

Source: design/materialFactorPresets.kt:18-58.

Cross-section classification

ε = √(235 MPa / fy)EN 1993-1-1 Table 5.2 · kernel steel/classification/steelBeamClassificationEpsilon.kt:6-12

fy is the design yield strength for the governing thickness. Each plate of the section is compared with the Table 5.2 limits on c/t:

PartClass 1Class 2Class 3
Internal part, compression33ε38ε42ε
Internal part, bending72ε83ε124ε
Outstand, compression9ε10ε14ε
Tube, d/t50ε²70ε²90ε²
Angle, h/t and (b + h)/2t––15ε and 11.5ε

A ratio above the Class 3 limit is Class 4, and the section takes the class of its least favourable plate. Beam checks classify for strong-axis bending. The class shows in the Member card header.

Source: steel/classification/BucklingElement.kt:12-117; steel/classification/BucklingElementRow.kt:18-24; verification/SteelBeamChecks.kt:181-186, 889.

Bending

Mc,Rd = W · fy / γM0, W = Wpl for Class 1 and 2, W = Wel,min for Class 3EN 1993-1-1 6.2.5 (6.13), (6.14) · kernel steel/SteelMemberVerifier.kt:405-417; steel/SteelResistanceSectionResolver.kt:63-72

The utilisation is |MEd| / Mc,Rd at every station; the highest governs.

When the coexistent shear at a station exceeds half the shear resistance, the moment resistance is reduced by EN 1993-1-1 6.2.8:

ρ = (2 · VEd/VRd − 1)²EN 1993-1-1 6.2.8 · kernel steel/SteelShearBendingReduction.kt:37-38
My,V,Rd = (Wpl,y − ρ · Aw² / (4 tw)) · fy / γM0 ≤ Mc,Rd, Aw = hw · twEN 1993-1-1 6.2.8 (6.30) · kernel steel/SteelShearBendingReduction.kt:39-47

VRd is the shear resistance already reduced for torsion. The reduction is applied for equal-flange I and H sections in Class 1 or 2 without warping demand; for other shapes, Class 3, or a shear ratio above 1, Bending reads Unsupported with the reason shear-bending interaction required.

When torsion creates a warping bimoment, Bending uses the cross-section interactions of SCI P385 3.1:

plastic: (My,Ed/My,Rd)² + Mz,Ed/Mz,Rd + Mw,Ed/Mw,Rd ≤ 1; elastic: My,Ed/My,Rd + Mz,Ed/Mz,Rd + Mw,Ed/Mw,Rd ≤ 1SCI P385 3.1.2 and 3.1.1 · kernel steel/SteelMemberVerifier.kt:97-107

Source: verification/SteelBeamChecks.kt:352-479.

Shear and shear with torsion

Vpl,Rd = Av · (fy / √3) / γM0EN 1993-1-1 6.2.6 (6.18) · kernel steel/SteelShearTorsionResistance.kt:5-8

The shear area Av follows EN 1993-1-1 6.2.6(3):

SectionAv
Rolled I or HA − 2btf + (tw + 2r)tf, not less than η · hw · tw
Welded I or Hη · hw · tw
Rolled channelA − 2btf + (tw + r)tf
Rolled TA − btf + (tw + 2r)tf/2
Welded Ttw · (h − tf/2)
Box with equal flangesη · 2 · hw · tw
Rectangular hollowA · h / (b + h)
Circular hollow2A / π

For zee and solid sections, welded channels and boxes with inclined webs, Statiko uses the shear area from its finite-element section analysis; the check details name this basis. Angles use the elastic shear resistance VRd = (fy/√3)/γM0 · I · t / S (EN 1993-1-1 6.2.6(4), (6.19) and (6.20); steel/SteelShearTorsionResistance.kt:40-51), and with torsion VRd,T = (1 − τt / ((fy/√3)/γM0)) · VRd (6.2.7(5) with 6.2.1(5); steel/SteelShearTorsionResistance.kt:53-62). η = 1.2 for fy ≤ 460 MPa and 1.0 above (EN 1993-1-5 5.1(2) Note 2).

Source: steel/SteelShearArea.kt:12-151; design/SteelShearEtaResolver.kt:20-35.

With torsion, the shear stress τt,Ed reduces the shear resistance by EN 1993-1-1 6.2.7(9). For I and H sections and channels it is the St Venant stress τt,Ed = Tt · t / It, with Tt = G · It · θ′ when a twist gradient exists and the total torque otherwise (steel/SteelShearTorsionCalculator.kt:93-106, :150-158). For hollow sections it is the Bredt stress τt,Ed = |T| / (2 · Am · t), with Am the area enclosed by the wall midline and t the wall thickness (steel/SteelShearTorsionResistance.kt:16-19):

I or H: Vpl,T,Rd = √(1 − τt,Ed / (1.25 · (fy/√3)/γM0)) · Vpl,RdEN 1993-1-1 6.2.7(9) (6.26) · kernel steel/SteelShearTorsionResistance.kt:20-24
Channel: Vpl,T,Rd = [√(1 − τt,Ed / (1.25 · (fy/√3)/γM0)) − τw,Ed / ((fy/√3)/γM0)] · Vpl,RdEN 1993-1-1 6.2.7(9) (6.27) · kernel steel/SteelShearTorsionResistance.kt:26-37
Hollow: Vpl,T,Rd = [1 − τt,Ed / ((fy/√3)/γM0)] · Vpl,RdEN 1993-1-1 6.2.7(9) (6.28) · kernel steel/SteelShearTorsionResistance.kt:63-66

Before the shear check, Statiko tests whether the web is slender enough for shear buckling:

hw / tw > 72 · ε / η ⇒ shear buckling check requiredEN 1993-1-1 6.2.6(6) (6.22) · kernel steel/SteelShearBucklingRelevance.kt:14-41

If it is, Shear reads Unsupported with the reason shear buckling required: the EN 1993-1-5 shear buckling resistance is not available in this version.

Torsion

The torsion check compares the largest torque with a resistance from the section's torsion modulus Wt, which Statiko's finite-element section analysis provides. This resistance form is Statiko's own method; the utilisation follows TEd/TRd ≤ 1 of EN 1993-1-1 6.2.7.

TRd = Wt · (fy / √3) / γM0, utilisation = |TEd| / TRdStatiko method · kernel steel/SteelTorsionCalculator.kt:33-36

Stability

Lateral-torsional buckling follows EN 1993-1-1 6.3.2 with Mcr from the eigenvalue analysis, χLT and Mb,Rd = χLT · Wy · fy / γM1; Chapter 17 gives every step. Flexural buckling under compression is not checked for beams, because the beam carries no axial force.

hbtw, c webtf, c outstandshaded: the web, hw · tw≤ 72ε≤ 83ε≤ 124εClass 4web in bending: Class 1 · 2 · 3 · 4 by c/t
Figure 18.1 · The plate widths c and thicknesses used for classification, and the class bands for a web in bending.

Results and limits

Each card shows the utilisation, status and governing combination and position; the check details show the terms: Wy, class, fy and γM0 for Bending; Av and its basis, Vpl,Rd, VRd and the buckling-relevance terms for Shear; Wt for Torsion (Chapter 12).

  • Unsupported, Unavailable, Invalid input and Failed calculation are separate statuses and never count as a pass.
  • Not available in this version: Class 4 beams, shear buckling resistance, the 6.2.8 reduction (6.29) for shapes other than equal-flange I and H, bending with axial force (6.2.9) and beam-column stability (6.3.3). A non-zero axial load makes every steel check Unsupported.
  • Torsion with lateral-torsional buckling is checked only on a simply supported single span.

Source: verification/SteelBeamChecks.kt:166-233, 501-516; verification/limitedToBeamAxialScope.kt:4-15.