Chapter 25
Scope, editions and limitations
This chapter states what Statiko designs, which Eurocode editions and National Annexes it uses, where it uses its own finite-element method and where it leaves Eurocode. Read it before you rely on a result for a member type or a country the chapter does not name. The Eurocode references tile on the hub's Documentation page opens this chapter.
What Statiko designs
Statiko designs single beams: steel (classes 1 to 3), timber, glulam and reinforced concrete, each with its normal design and its fire design. One beam is analysed as a line of beam elements on its supports, with its loads, combinations, checks and PDF report (Chapter 16).
Not in Statiko:
- 3D models: Statiko analyses one straight beam, never a spatial structure.
- Frames: no beam is connected to a column or to another beam.
- Connections: no bolts, welds, end plates or timber fasteners are designed.
- Foundations: the support reactions are reported, but no footing or soil is designed.
Source: statiko spec/guide.md › Scope; this guide's chapters 16 to 22.
Eurocode editions
Statiko calculates with the first generation of the Eurocodes, in the editions below. The report states the edition of the design code and of the basis of design on its Basis of design page (Chapter 14).
| Part | Edition | Used for |
|---|---|---|
| EN 1990 | EN 1990:2002 + A1:2005 | Basis of design, load combinations (Chapter 15) |
| EN 1993-1-1 | EN 1993-1-1:2005 + AC:2009 | Steel checks (Chapter 18) |
| EN 1993-1-5 | EN 1993-1-5:2006 + AC:2009 | The shear factor η (Shear) |
| EN 1995-1-1 | EN 1995-1-1:2004 + AC:2006 + A1:2008 | Timber and glulam checks (Chapter 19) |
| EN 1992-1-1 | EN 1992-1-1:2004 + A1:2014 | Concrete checks (Chapter 20) |
| EN 1991-1-2 | EN 1991-1-2:2002 | Fire actions (Fire actions) |
| EN 1993-1-2 | EN 1993-1-2:2005 | Steel in fire |
| EN 1995-1-2 | EN 1995-1-2:2004 | Timber and glulam in fire |
| EN 1992-1-2 | EN 1992-1-2:2004 | Concrete in fire |
Source: resources localization/design/DesignStrings.kt:34,37,44; resources ConcreteStringsEn.kt:459; engineering SteelShearEtaProvenance.kt:3; statiko ai/eurocode/sources/register.tsv (fire parts); reports reportBasis.kt:74-75.
National Annexes
A project has one design code (Chapter 5). The choices are:
- Eurocode recommended values: the values the Eurocode parts recommend.
- Denmark (DS EN), Sweden (SS EN) and Serbia (SRPS EN): the nationally determined parameters of that country's National Annexes.
- Custom values: values you enter yourself. Statiko does not check them against any National Annex; their source is yours to state.
Concrete beams do not calculate under Sweden (SS EN), because the Swedish National Annex to EN 1992-1-1 is not in Statiko yet. Norway is not a design code choice, and there is no United Kingdom National Annex.
Source: project domain/design/AnnexDesignCountry.kt:3-9; resources DesignStringsEn.kt:24,40,60-62; spec/beam/concrete-workspace.md rule 4.
Where Statiko uses its own finite-element method
Where Eurocode leaves the method to the designer or gives no formula, Statiko uses its own finite-element method, and the guide names it each time:
- The static analysis of the beam: Eurocode prescribes no beam formulation (The beam model).
- The elastic critical moment Mcr: EN 1993-1-1 6.3.2.2(2) gives no formula, so Statiko solves a linear buckling eigenvalue problem over the whole member, with no effective-length table. Steel uses it for χLT (Critical moment as an eigenvalue), timber and glulam for kcrit (Timber).
- The natural frequency: an eigenvalue problem of the same beam model (Natural frequency).
- The section analysis: the torsion modulus Wt and, for some steel shapes, the shear area (Shear).
Source: statiko ai/architecture/engineering-rules.md:5-9; engineering fem/ltb/CriticalBucklingCalculator.kt:39.
Results beyond Eurocode
One result is marked beyond Eurocode in the check details and the report: Finite-element shear area, beyond Eurocode. Statiko uses it for zee and solid sections, welded channels and boxes with inclined webs, for which EN 1993-1-1 6.2.6(3) gives no shear area (Shear).
The steel torsion resistance TRd = Wt · (fy / √3) / γM0 is Statiko's own form; the utilisation follows TEd/TRd ≤ 1 of EN 1993-1-1 6.2.7 (Torsion).
Source: resources ReportStringsEn.kt:57; reports steelReportCrossSection.kt:77; engineering steel/SteelShearArea.kt:12-151, steel/SteelTorsionCalculator.kt:33-36.
Limits of this version
Each calculation chapter lists what this version does not check. A check outside these limits reads Unsupported or Unavailable, never Pass.
- Static analysis: Limits.
- Steel: Results and limits.
- Timber and glulam: Limits of this version.
- Concrete: What you see and the limits.
Source: this guide's chapters 16, 18, 19 and 20.